QP-100 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION QP-100-3A MODEL OUTPUT CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 12V -5V 5V 3.3V 12V -12V 5V 3.3V 15V -15V RATED CURRENT 8A 8A 2.5A 0.6A 8A 8A 2.2A 0.6A 8A 8A 1.7A 0.6A CURRENT RANGE 2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A RATED POWER (max.) 99.4W CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE 100.9W CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% +8,-6% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD UP TIME (Typ.) 24ms/230VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC COLD START 800ms, 50ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 74% <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING 75% 0.75A/230VAC 40A/230V LEAKAGE CURRENT WORKING TEMP. 5.0% 24ms/115VAC at full load Note.5 90 ~ 264VAC FREQUENCY RANGE OVER TEMPERATURE(OPTION) NOTE 100W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p PROTECTION OVER VOLTAGE OTHERS QP-100-3C CH1 VOLTAGE RANGE INPUT QP-100-3B OUTPUT NUMBER CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 139.9K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.87Kg; 20pcs/18.4Kg/1.28CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100-SPEC 2011-08-19 QP-100 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION QP-100-3D MODEL OUTPUT CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 24V -12V 5V 12V 24V -12V 5V 15V 24V -15V RATED CURRENT 8A 8A 1.3A 0.6A 8A 2.4A 1A 0.6A 8A 2A 1A 0.6A CURRENT RANGE 2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A 2 ~ 10A 0 ~ 3A 0.3 ~ 2A 0 ~ 1A 2 ~ 10A 0 ~ 3A 0.3 ~ 2A 0 ~ 1A RATED POWER (max.) 104.8W 103W CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD UP TIME (Typ.) 24ms/230VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC COLD START PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING 5.0% 800ms, 50ms/115VAC at full load 24ms/115VAC at full load Note.5 90 ~ 264VAC FREQUENCY RANGE OVERLOAD NOTE 100W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 180mVp-p 200mVp-p 150mVp-p VOLTAGE ADJ. RANGE LEAKAGE CURRENT OTHERS QP-100F CH1 VOLTAGE RANGE INPUT QP-100D OUTPUT NUMBER 127 ~ 370VDC PF>0.98/115VAC at full load 78% 78% 0.75A/230VAC 40A/230V <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover CH2:17.25 ~ 20.25V 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 139.9K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.87Kg; 20pcs/18.4Kg/1.28CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100-SPEC 2011-08-19 UQSPP- -1 0202 s5e r i e ss e r i e 100W Quad Output with PFC Function Mechanical Specification Case No. 916A Unit:mm 199 20 35 133 25 117 70 65 LED +V ADJ.2 +V ADJ.1 49.5 99 119 51 79 2-M4 5-M3 L=6mm 16 10 38 6.15 7.62 10 9 8 7 6 5 4 3 2 1 15 142 25 Terminal Pin No. Assignment : Pin No. Pin No. Assignment Assignment 1 5 AC/L DC OUTPUT V3 2 6,7 AC/N DC OUTPUT V1 3 FG 8,9 DC OUTPUT COM 4 DC OUTPUT V4 10 DC OUTPUT V2 25 12.5 50 25 8 max. 6-M4 L=6mm Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER V4 REGULATOR V3 RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 110 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:QP-100-SPEC 2011-08-19