PETERMANN M2352

FEATURES
PETERMANN
- HIGH RELIABILITY FOR LOW COST
- FREQUENCY STABILITY TO +-15 PPM
- JITTER OPTIMIZED DIP 8 CLOCK OSCILLATOR
- EXCELLENT CLOCK SIGNAL GENERATOR FOR DSP'S AND CPU'S
TECHNIK
Time & Frequency Components
- EXTENDED TEMPERATURE RANGE TO -40/+85°C
M2352
8 PIN DIP
125.0 ~ 180.0 MHz
+-15 ~ +-100 ppm
+-5 ppm after first year
0/+70°C ~ -40/+85°C
-55/+125°C
+3.3 VDC +-10%
40 mA max.
40/60%
45/55%
10 ns max. (10% VDD ~ 90% VDD)
10% VDD max.
90% VDD min.
15 pF
WITHOUT ENABLE/DISABLE FUNCTION
WITH ENABLE/DISABLE FUNCTION
PIN 8 OUTPUT
PIN 1 INPUT
TRISTATE LOGIC TABLE
2.0V MIN. OR NOT CONNECTED
OSCILLATION
0.8V MAX. OR GND
HIGH IMPEDANCE
SEE OUTLINE DRAWINGS
PIN CONNECTION
10 ms max.
START-UP TIME
25 ps max.
PERIOD JITTER RMS
OTHER PARAMETERS ARE AVAILABLE ON REQUEST / CREATE HERE YOUR SPECIFICATION
SERIES
PACKAGE
FREQUENCY RANGE
FREQUENCY STABILITY
AGING
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
VOLTAGE
INPUT
CURRENT
STANDARD
SYMMETRY
OPTION
RISE AND FALL TIME HCMOS
OUTPUT
"0" LEVEL
HCMOS 3.3 VOLT
"1" LEVEL
LOAD
HCMOS
STANDARD
PIN 1
OPTION
PART NUMBERING SYSTEM
EXAMPLE
SERIES
FREQUENCY STABILITY
TEMPERATURE RANGE
SYMMETRY
PIN 1
ENABLE/DISABLE
PIN CONFIGURATION
FREQUENCY
M2352-25-W-S-E-G-180.0MHz
M2352
BLANK FOR 100 PPM
ANY 50 ~ 15 PPM
BLANK FOR 0/+70°C
N = -10/+60°C
M = -20/+70°C
W = -40/+85°C
BLANK FOR 40/60%
S FOR 45/55%
BLANK FOR NO E/D
E FOR E/D
BLANK FOR DIP
G FOR GULL WING
REQUIRED FREQUENCY
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]
PETERMANN
TECHNIK
Time & Frequency Components
OUTLINE DRAWING OF M2352 GULL WING
OUTLINE DRAWING OF M2352
6.8max 5.3max
1.14
7.62+0.1
-
7.62+0.1
-
12.7max
1.27+0.127
-
#1
#4(Grounded to the Case)
#1
#5
#4
5.5max
0.8
4-00.55max
14.98+0.2
-
12.7max
0.63+0.1
-
#8
12.9max
7.62
Unit: mm
PIN
#1
#4
#5
#8
#8 #5
7.62
12.9max
Connection
NC/Tri-State
GND
Output
VDD
Unit:mm
HCMOS OUTPUT WAVE FORM
TEST CIRCUIT FOR HCMOS
+
+
POWER
SUPPLY
-
mA
M
(HCMOS LOAD)
TEST
POINT
#14
+
VM
-
tr
VCC
OUT
OSCILLATOR
0,1µF
GND
#1
tf
#8
VOH
90%VDD
CL =15pF
50%VDD
#7
TRI-STATE-INPUT
10%VDD
NOTE: CL includes probe and fixture capacitance
VOL
Th
DUTY=Th/T
T
PETERMANN-TECHNIK | Amselweg 8 | D-86916 Kaufering
Fon: 00 49 (0) 81 91 / 30 53 95 | Fax: 00 49 (0) 81 91 / 30 53 97
http://www.petermann-technik.de | [email protected]