PHIHONG POE36U-1AT

WWW.PHIHONG.COM
33.6W Power Over Ethernet Adapter
High Power single port injector.
Features
•
•
•
•
Fully Compliant detection, disconnect and
voltage control IEEE802.3af
Diagnostic LEDs
Non-Vented Case
Classification per 802.3at
Applications
•
•
•
IP Telephones
Wireless Network Access Points
Blue Tooth Access Point
•
UNH IOL Tested
•
•
Full Protection OCP, OVP
Gigabit Compatible
•
•
Security Camera
IP Print Servers
•
•
Height: 36mm (1.42in)
Weight: 0.2Kg (0.44lb.)
Safety Approvals
•
•
cUL/UL
CE
Mechanical Characteristics
•
•
Length: 140mm (5.51in)
Width: 65mm (2.55in)
Output Specifications
Model
DC Output
Voltage
POE36U-1AT
56V
Ripple And Noise*
<500Hz
500Hz-150KHz
150KHz-500KHz
500KHz-1MHz
Vp-p*
0.5
0.15
0.15
0.1
*As per IEEE802.3af Table 33-5.
Load
Regulation
Min.
Max.
0A
0.60A
Line
Load
54-57Vdc under all conditions
Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and
visit www.phihong.com for the most up-to-date specifications.
POE36U Characteristics
INPUT:
WWW.PHIHONG.COM
AC Input Voltage Range
90 to 264VAC
AC Input Voltage Rating
100 to 240VAC,47-63Hz
AC Input Current
1.0A(RMS) max. for 90VAC
0.55A(RMS) max. for 240VAC
EMC
FCC Part 15 Class B
EN55022 Class B
Leakage Current
3.5mA max. @ 254VAC 60Hz
Isolation Test
AC Inrush Current
Primary to Secondary: 3000VAC for 1 minute 10mA
Primary to F.G.: 1500VAC for 1 minute
Output to F.G.: 1500VAC
30A(RMS) max. for 115VAC
40A(RMS) max. for 230VAC
Immunity
OUTPUT:
Total Output Power
33.6W
DC Offset
No Data degradatio with DC imbalance 18mA
Efficiency
78% (typical) at Max. load, and 120VAC 60Hz
Hold-up Time
16mS min. 120VAC and max. load
ESD:
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
EN61000-3-2
Insulation Resistance
Primary to secondary: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
FEATURE:
Transient O/P Voltage Protection
Over Voltage/Current, Short Circuit Protection
60V max.
Outputs equipped with short circuit protection and overload
protection as per 802.3at specification
The output can be shorted permanently without damage
ENVIRONMENTAL:
Temperature
Operation
Non-operation
-20 to +50°C
-25 to +65°C
Humidity
Operation
5 to 90%
Dimension Diagram Unit: mm (inch)
Indicators
Led #1 indicator for input power “on” GREEN
Led #2 Indicator for Class 4 PD connected GREEN
Led #3 Indicator that Detected and Connected to valid
IEEE802.3af load-GREEN
Input Connector
IEC320 inlet 3 pin
Output Connection
+pins 3,6
- pins 1,2
Gigabit Power Injector Block Diagram
Description of LED Functions for Gigabit Power Injector
Power-up Sequence:
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal microprocessor
software. After the end of the 2 seconds, the "ON" LED will illuminate green, signifying that the DC
output voltage is available for powering a compliant load (to the 802.3af PoE standards).
Detection Sequence:
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate. Should the load is classified as Class 4 PD, the green “PoEPLUS” LED will illuminate.
Otherwise, “PoEPLUS” LED will stay off.
Should the load be non-compliant then the LEDs will blink a code signifying the cause for non-detection.
Detection Failure Codes:
1.
2.
3.
4.
5.
Incorrect resistive signature – The green “CONNECT” and green “PoEPLUS” LEDs will blink 3 times.
Incorrect capacitive signature – The green “ON” LED will blink 3 times.
Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
Unstable current measurement – The green “CONNECT” LED will blink 3 times
Low voltage sensed during detection (overload) – The green “PoE PLUS” LED will blink 3 times
After the LEDs blink 3 times the PSE will continue to try to detect a valid load. Therefore, until the
correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the output
RJ45 then the LEDs will not blink but the PSE will continue to try to detect a valid load.
Fault Sequence:
Should there be a fault such as an overload or short circuit then all the three LEDs will blink 5 times in 2
seconds, and then go off as the power supply tries to re-detect a valid load. If there is a problem in
detecting, the LED will indicate what is wrong with the load as per the codes in the section above.