WWW.PHIHONG.COM 33.6W Power Over Ethernet Adapter High Power single port injector. Features • • • • Fully Compliant detection, disconnect and voltage control IEEE802.3af Diagnostic LEDs Non-Vented Case Classification per 802.3at Applications • • • IP Telephones Wireless Network Access Points Blue Tooth Access Point • UNH IOL Tested • • Full Protection OCP, OVP Gigabit Compatible • • Security Camera IP Print Servers • • Height: 36mm (1.42in) Weight: 0.2Kg (0.44lb.) Safety Approvals • • cUL/UL CE Mechanical Characteristics • • Length: 140mm (5.51in) Width: 65mm (2.55in) Output Specifications Model DC Output Voltage POE36U-1AT 56V Ripple And Noise* <500Hz 500Hz-150KHz 150KHz-500KHz 500KHz-1MHz Vp-p* 0.5 0.15 0.15 0.1 *As per IEEE802.3af Table 33-5. Load Regulation Min. Max. 0A 0.60A Line Load 54-57Vdc under all conditions Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and visit www.phihong.com for the most up-to-date specifications. POE36U Characteristics INPUT: WWW.PHIHONG.COM AC Input Voltage Range 90 to 264VAC AC Input Voltage Rating 100 to 240VAC,47-63Hz AC Input Current 1.0A(RMS) max. for 90VAC 0.55A(RMS) max. for 240VAC EMC FCC Part 15 Class B EN55022 Class B Leakage Current 3.5mA max. @ 254VAC 60Hz Isolation Test AC Inrush Current Primary to Secondary: 3000VAC for 1 minute 10mA Primary to F.G.: 1500VAC for 1 minute Output to F.G.: 1500VAC 30A(RMS) max. for 115VAC 40A(RMS) max. for 230VAC Immunity OUTPUT: Total Output Power 33.6W DC Offset No Data degradatio with DC imbalance 18mA Efficiency 78% (typical) at Max. load, and 120VAC 60Hz Hold-up Time 16mS min. 120VAC and max. load ESD: RS: EFT: Surge: CS: Voltage Dips Harmonic: EN61000-4-2. Level 3 EN61000-4-3. Level 2 EN61000-4-4. Level 2 EN61000-4-5. Level 3 EN61000-4-6. Level 2 EN61000-4-11 EN61000-3-2 Insulation Resistance Primary to secondary: >10M OHM 500VDC Primary to FC: >10M OHM 500VDC FEATURE: Transient O/P Voltage Protection Over Voltage/Current, Short Circuit Protection 60V max. Outputs equipped with short circuit protection and overload protection as per 802.3at specification The output can be shorted permanently without damage ENVIRONMENTAL: Temperature Operation Non-operation -20 to +50°C -25 to +65°C Humidity Operation 5 to 90% Dimension Diagram Unit: mm (inch) Indicators Led #1 indicator for input power “on” GREEN Led #2 Indicator for Class 4 PD connected GREEN Led #3 Indicator that Detected and Connected to valid IEEE802.3af load-GREEN Input Connector IEC320 inlet 3 pin Output Connection +pins 3,6 - pins 1,2 Gigabit Power Injector Block Diagram Description of LED Functions for Gigabit Power Injector Power-up Sequence: Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal microprocessor software. After the end of the 2 seconds, the "ON" LED will illuminate green, signifying that the DC output voltage is available for powering a compliant load (to the 802.3af PoE standards). Detection Sequence: Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will illuminate. Should the load is classified as Class 4 PD, the green “PoEPLUS” LED will illuminate. Otherwise, “PoEPLUS” LED will stay off. Should the load be non-compliant then the LEDs will blink a code signifying the cause for non-detection. Detection Failure Codes: 1. 2. 3. 4. 5. Incorrect resistive signature – The green “CONNECT” and green “PoEPLUS” LEDs will blink 3 times. Incorrect capacitive signature – The green “ON” LED will blink 3 times. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times. Unstable current measurement – The green “CONNECT” LED will blink 3 times Low voltage sensed during detection (overload) – The green “PoE PLUS” LED will blink 3 times After the LEDs blink 3 times the PSE will continue to try to detect a valid load. Therefore, until the correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the output RJ45 then the LEDs will not blink but the PSE will continue to try to detect a valid load. Fault Sequence: Should there be a fault such as an overload or short circuit then all the three LEDs will blink 5 times in 2 seconds, and then go off as the power supply tries to re-detect a valid load. If there is a problem in detecting, the LED will indicate what is wrong with the load as per the codes in the section above.