PHIHONG POE80U

WWW.PHIHONG.COM
80W Power over Ethernet Adapter
High Power Single Port Injector
Features




Fully Compliant Detection, Disconnect and
Voltage Control IEEE802.3af
Diagnostic LEDs
Gigabit Compatible
1 Year Warranty
Applications



Satellite Receiver
Wireless Network Access Points
LCD Displays
Safety Approvals




cUL/UL
CE
C-Tick
IRAM
Mechanical Characteristics


Length: 203mm (8in)
Width: 108mm (4.25in)




Single Source 4 Pair Power Current Sharing
Wide Temperature range -40 to +55˚C
Full Protection OCP, OVP
Broken Wire Detection



Security Cameras
Kiosks
Computer Workstations



CCC
SAA
Korea (PHC)


Height: 63mm (2.5in)
Weight: 1.93Kg
Output Specifications
Model
DC Output
Voltage
POE80U-560G
+56V
+56V
Load
Regulation
Min.
Max.
0A
0.72A
Line
Load
54-57V DC under all conditions
Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at
www.phihong.com for the most up-to-date specifications and contact information.
Revision 11/17/2011
POE80U Characteristics
INPUT:
AC Input Voltage Range
WWW.PHIHONG.COM
EMC
85 to 264VAC
FCC Part 15 Class B
EN55022 Class B
AC Input Voltage Rating
Isolation Test
100 to 240VAC, 47-63Hz
AC Input Current
Primary to Secondary: 4242VDC for 1 minute 10mA
Primary to Field Ground: 2121VDC for 1 minute
Output to Field Ground: 2121VDC
2.0A (RMS) maximum for 90VAC
1.2A (RMS) maximum for 240VAC
Immunity
Leakage Current
3.5mA maximum @ 254VAC 60Hz
AC Inrush Current
50A (RMS) maximum for 115VAC
50A (RMS) maximum for 230VAC
Primary to Secondary: >10M OHM 500VDC
Primary to Field Ground: >10M OHM 500VDC
80W
IEEE 802.3af/at Interoperability
DC Offset
No data degradation with DC imbalance 18mA per
min.
Ripple and Regulation
100mV maximum
Efficiency
75% (typical) at maximum load, and 120VAC 60Hz
Hold-up Time
10mS min. 120VAC and maximum load
Transient O/P Voltage Protection
60V maximum at switch on and off at any point on
AC line phase
ENVIRONMENTAL:
Temperature
-40 to +55°C
-50 to +85°C
UNH Interoperability report available upon request
FEATURE:
Detection
12.5kohm detection resistor value required to turn
on full power 4 pair power.
Over Voltage/Current, Short Circuit Protection
Outputs equipped with short circuit protection and
overload protection as per 802.3af specifications
except max average pair current is 0.72A, Peak
1.4A per pair. The output can be shorted
permanently without damage
Indicators
Green LED 1: DC Power “OK”
Red LED: Fault detected
Green LED 2: Power detected “CONNECT” at
80W
Input Connector
IEC320 inlet 3 pin
Humidity
Operation
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
EN61000-3-2
Insulation Resistance
OUTPUT:
Total Output Power
Operation
Non-operation
ESD:
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
5 to 90%
Warranty
1 Year
Dimension Diagram Unit: mm
WWW.PHIHONG.COM
Description of LED Functions for Gigabit Power Injector
Power-up Sequence:
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal
microprocessor software. After the 2 second period, the "ON" LED will illuminate green. The DC
output voltage is now available for powering a compliant load (Phihong Proprietary detetcion).
Detection Sequence:
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate.
Should the load be non-compliant then the LEDs will blink a code specific to the cause for nondetection.
Detection Failure Codes:
1. Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink 3 times.
2. Incorrect capacitive signature – The green “ON” LED will blink 3 times.
3. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
4. Unstable current measurement – The green “ON” LED will blink 3 times
5. Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3 times
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load. Until the
correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the
output RJ45 then the LEDs will not blink but the Power Injector will continue to try to detect a valid
load.
Fault Sequence:
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate.
The red “FAULT” LED will illuminate for 2 seconds and then go off as the power supply tries to redetect a valid load. If there is a problem detecting the load, the LED will indicate the possible fault as
per the codes in the section above.