PHIHONG PSA16U-480

WWW.PHIHONG.COM
Single Port 15.4W Power Over Ethernet Adapter
PSA16U IEEE 802.3af compliant
Features
•
•
•
Fully Compliant with IEEE802.3af
Diagnostic LEDs
Non-Vented Case
Applications
•
•
•
IP Telephones
Wireless Network Access Points
Blue Tooth Access Point
Safety Approvals
•
•
•
•
cUL/UL
CE
CCC
S-Jet
Mechanical Characteristics
•
•
Length: 140mm (5.51in)
Width: 65mm (2.55in)
•
•
•
IOL Test Report
Full Protection OTP, OCP, OVP
Data and Power carried over one Ethernet Cable
•
•
Security Camera
IP Print Servers
•
•
•
TUV
FCC
SAA
•
•
Height: 36mm (1.42in)
Weight: 0.2Kg (0.44lb.)
Output Specifications
Model
DC Output
Voltage
PSA16U-480(POE)
48V
Ripple And Noise*
<500Hz
500Hz-150KHz
150KHz-500KHz
500KHz-1MHz
Load
Regulation
Min.
Max.
0A
0.35A
Line
Load
±4%
Vp-p*
0.5
0.15
0.15
0.1
*As per IEEE802.3af Table 33-5. For Legacy detection or AC disconnect please contact the factory.
Phihong is not responsible for any error and change. Content is subject to change without notice. Please consult the factory and
visit www.phihong.com for the most up-to-date specifications.
PSA16U-480(POE) Characteristics
INPUT:
WWW.PHIHONG.COM
AC Input Voltage Range
EMC
90 to 264VAC
FCC Part 15 Class B
EN55022 Class B
VCCI, C-Tick
AC Input Voltage Rating
100 to 240VAC
Isolation Test
0.5A(RMS) max. for 90VAC
0.35A(RMS) max. for 240VAC
Primary to Secondary: 3000VAC for 1 minute 10mA
Primary to F.G.: 1500VAC for 1 minute
Output to F.G.: 1500VAC
Leakage Current
Immunity EN50082-1
0.25mA max. @ 254VAC 60Hz
ESD:
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
AC Input Current
AC Input Frequency
47-63Hz
AC Inrush Current
15A(RMS) max. for 115VAC
20A(RMS) max. for 230VAC
Total Output Power
15.4W
FEATURE:
Over Voltage/Current, Short Circuit Protection
Efficiency
65% (typical) at Max. load, and 120VAC 60Hz
Hold-up Time
16mS min. 120VAC and max. load
Transient O/P Voltage Protection
60V max. at switch on and off at any AC line Phase
ENVIRONMENTAL:
Temperature
0 to +40°C
-25 to +65°C
Humidity
Operation
Insulation Resistance
Primary to secondary: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
OUTPUT:
Operation
Non-operation
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
EN61000-3-2
5 to 90%
Dimension Diagram Unit: mm (inch)
Outputs equipped with short circuit protection and overload
protection as per 802.3af specification
The output can be shorted permanently without damage
Indicators
Led #1 indicator for input power “on” GREEN
Led #2 Indicator for fault-RED
Led #3 Indicator that Detected and Connected to valid
IEEE802.3af load-GREEN
Input Connector
IEC320 inlet 3 pin
PSA16U 480(POE) Led Function
WWW.PHIHONG.COM
Power Injector Block Diagram
RJ45
Data
IN
RJ45
1
2
3
6
1
2
3
6
5
4
7
8
5
4
7
8
+
-
PoE
Power &
Control
Power-up Sequence:
Data
&
Power
Out
On
Power
Connect
Description of LED Functions for Power Injector
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal microprocessor
software. After the end of the 2 seconds, the "ON" LED will illuminate green, signifying that the DC
output voltage is available for powering a compliant load (to the 802.3af PoE standards).
Detection Sequence:
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate.
Should the load be non-compliant then the LEDs will blink a code signifying the cause for non-detection.
Detection Failure Codes:
1.
2.
3.
4.
5.
Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink 3 times.
Incorrect capacitive signature – The green “ON” LED will blink 3 times.
Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
Unstable current measurement – The green “ON” LED will blink 3 times
Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3 times
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load. Therefore, until
the correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the
output RJ45 then the LEDs will not blink but the Power Injector will continue to try to detect a valid load.
Fault Sequence:
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate.
The red “FAULT” LED will illuminate for 2 seconds and then go off as the power supply tries to redetect a valid load. If there is a problem in detecting, the LED will indicate what is wrong with the load
as per the codes in the section above.