POWER-ONE IMP

IMP Series
1...12 Watt DC-DC Converters
Input voltage range up to 72 V DC
1, 2 or 3 outputs up to 30 V DC
1500 V DC I/O electric strength test voltage
• Wide input range
• Short circuit protection
• Low cost
Selection chart
Output 1
Output 2
Output 3
Uo nom Io nom Uo nom Io nom Uo nom Io nom
[V DC] [mA] [V DC] [mA] [V DC] [mA]
3.3 1500
3.3 3000
5
200
5
500
5 1000
5 2400
12
84
12 250
12 500
12 1000
15
66
15 200
15 400
15 800
+5 100
–5 100
+5 250
–5 250
+5 500
–5 500
+5 1200
–5 1200
+12 42
–12 42
+12 125
–12 125
12 125
12 125
+12 250
–12 250
+12 500
–12 500
+15 33
–15 33
15 100
15 100
+15 100
–15 100
+15 200
–15 200
+15 400
–15 400
5
250
5
250
5 1500
+12 200
–12 200
5 1500
+15 160
–15 160
www.power-one.ch
Edition 6/11.2001
Type
Input voltage
4.5...5.5 V DC
5 IMP 6-03-7
5 IMP 1-05-7
5 IMP 6-05-7
5 IMP 1-12-7
5 IMP 6-12-7
5 IMP 1-15-7
5 IMP 6-15-7
5 IMP 1-0505-7
5 IMP 6-0505-7
5 IMP 1-1212-7
5 IMP 6-1212-7
5 IMP 1-1515-7
5 IMP 6-1515-7
-
Type
Input voltage
10...36 V DC
24 IMP 6-03-7
24 IMP 12-03-7
24 IMP 3-05-7
24 IMP 6-05-7
24 IMP 12-05-7
24 IMP 3-12-7
24 IMP 6-12-7
24 IMP 12-12-7
24 IMP 3-15-7
24 IMP 6-15-7
24 IMP 12-15-7
24 IMP 3-0505-7
24 IMP 6-0505-7
24 IMP 12-0505-7
24 IMP 3-1212-7
24 IMP 3-12-12-7
24 IMP 6-1212-7
24 IMP 12-1212-7
24 IMP 3-15-15-7
24 IMP 3-1515-7
24 IMP 6-1515-7
24 IMP 12-1515-7
24 IMP 3-05-05-7
24 IMP 12-051212-7
24 IMP 12-051515-7
Type
Input voltage
18...72 V DC
48 IMP 6-03-7
48 IMP 12-03-7
48 IMP 3-05-7
48 IMP 6-05-7
48 IMP 12-05-7
48 IMP 3-12-7
48 IMP 6-12-7
48 IMP 12-12-7
48 IMP 3-15-7
48 IMP 6-15-7
48 IMP 12-15-7
48 IMP 3-0505-7
48 IMP 6-0505-7
48 IMP 12-0505-7
48 IMP 3-1212-7
48 IMP 3-12-12-7
48 IMP 6-1212-7
48 IMP 12-1212-7
48 IMP 3-15-15-7
48 IMP 3-1515-7
48 IMP 6-1515-7
48 IMP 12-1515-7
48 IMP 3-05-05-7
48 IMP 12-051212-7
48 IMP 12-051515-7
Opt.
S
S
S
S
S
S
S
S
S
S
S
S
-
1
Board Mountable
IMP Series
Input
Input voltage
Reverse voltage protection
continuous range, 5 V (IMP 1, IMP 6)
continuous range, 24 V
continuous range, 48 V
shunt diode
4.5...5.5 V DC
10...36 V DC
18...72 V DC
Output
Output voltage setting accuracy
Minimum load
Line regulation
Load regulation
Output voltage switching noise
Efficiency
Ui nom, lo nom
recommended
Ui min...Ui max, lo nom
Ui nom , 0...100% lo nom , regulated outputs
tracking outputs
Ui nom , 20...100% lo nom, peak-peak, total
Ui nom , lo nom
±2% Uo nom
20% lo nom
±1% Uo nom
2% Uo nom
max. 6% Uo nom
max. 3% Uo nom
up to 83%
Control and protection
Overload protection
No-load protection
Remote shut down
Ui min, full load
125% Pi nom
positive logic (floating or high signal = on)
Safety and EMC
Electric strength test voltage
Electromagnetic interference
I/O
conducted with external filter
1500 V DC
class B
Environmental
Operating ambient temperature
Storage temperature
Relative humidity
MTBF
Ui nom , lo nom
non operational
non condensing
MIL-HDBK-217F, N2
–25...71°C
–40...100°C
95%
>3'700'000 h
Options
Industry standard pinout
IMP 1 and IMP 3
S
Accessories
DIN and chassis mounting bracket
www.power-one.ch
Edition 6/11.2001
2
IMP Series
1...12 Watt DC-DC Converters
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
IMP 1, IMP 3
Pin allocation IMP 1
31.8 (1.25")
20.3 (0.8")
15.24 (0.6")
2.54 (0.1")
Measuring point
of case temperature TC
S09034
12 (0.47")
3 (0.12")
European
Projection
Pin
1
2
10
11
12
13
15
23
24
Single output unit
Vi+
Vi+
Vo–
Vo+
Vi–
Vi–
Dual output unit
Vi+
Vi+
COM
COM
Vo–
Vo+
Vi–
Vi–
ø 0.5 (0.02")
(
)
Industry standard pinout (option S)
Pin
2
3
9
10
11
14
15
16
22
23
Single output
Vi–
Vi–
n.c.
n.c.
n.c.
Vo+
n.c.
Vo–
Vi+
Vi+
www.power-one.ch
Edition 6/11.2001
Dual output
Vi–
Vi–
COM
n.c.
Vo–
Vo+
n.c.
COM
Vi+
Vi+
Alternative pinout IMP 3
Pin
1
2
9
10
11
12
13
15
16
20
23
24
Single output Dual output Double output
Vi+
Vi+
Vi+
Vi+
Vi+
Vi+
Go1
COM
COM
Vo–
Vo1
Vo+
Vo–
Vo2
Vo+
Go2
SD
SD
SD
Vi–
Vi–
Vi–
Vi–
Vi–
Vi–
3
Board Mountable
IMP Series
IMP 6, IMP 12 with single or dual output
5 (0.2") 12 (0.47")
50.8 (2")
5.08 (0.2")
S09035
20.32 (0.8")
ø 1(0.04")
COM
Vo–
50.8 (2")
Vi+
Vi–
Vo+
2 x 10.2 (0.4")
Measuring point of case temperature TC
IMP 12 with triple output
50.8 (2")
5 (0.2") 12 (0.47")
12.7 (0.5") 3 x 5.08 (0.2")
Vo3-
COM
Vo1+
50.8 (2")
Vi– Vi+
SD
45.72 (1.8")
ø 1(0.04")
S09047
Vo2+
5 x 10.16 (0.42")
Measuring point of case temperature TC
www.power-one.ch
Edition 6/11.2001
4