POWER-ONE QBS050YE-A

(888) IPD-CONVerters ● (888) 473-2668
●
www.ipdconverters.com
QBS SERIES - 120 WATT
Rev. 04/2001
DESCRIPTION
FEATURES
QBS single output DC/DC converters provide up to
120 Watts of output power in an industry standard,
quarter-brick footprint. The QBS converters feature
open-frame packaging, along with planar magnetics to
provide maximum useable power with minimal
thermal constraints. The QBS is especially suited to
telecom, networking, and industrial applications, and
is fully compatible with production board washing
processes.
• “Quarter-Brick”
• High Power Density Up
To 120W
• Open-Frame Packaging
• 100°C Baseplate Operation
• Water Washable
• Outputs From
2.5V to 15V
• 1500V Isolation
• Positive or Negative
Enable Logic
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Input Reverse Voltage Protection
18 - 36 VDC
36 - 75 VDC
Shunt Diode
Output
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit And Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Limit
OVP Trip Range
UVP Trip Range
OVP/UVP Type
±1%
0.2% Vout
0.5% Vout
0.5 VDC
10 % lout Rated
25% Iout
4% Vout
500 µs
±10%
Shutdown
110 - 140%
200% I out
115 - 140% Vout Nom.
70 - 90% Vout Nom.
Latching
Efficiency vs. Load (48V Input)
90
85
EFFICIENCY %
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Remote Sense Headroom
Minimum Output Current
80
QBS100ZG-ANT
75
EFF. (36v)
EFF. (48v)
70
EFF. (75v)
65
60
10
20
30
40
50
60
LOAD%
70
80
90
100
General
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
30 ms
Positive or Negative Logic
Vin Negative
400 kHz
1500 VDC
1050 VDC
1050 VDC
0.02 ppm/°C
-40°C To +100°C
-40°C To +125°C
105°C To 115°C
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, CUL, TUV
1.7 oz
1
Notes
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
QBS SERIES - 120 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
24
24
24
24
24
48
48
48
48
48
48
48
48
48
18 - 36
18 - 36
18 - 36
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
2.90
3.50
5.20
6.80
6.80
1.40
1.70
2.50
3.30
4.00
3.30
2.50
3.45
4.00
2.5
3.3
5
12
15
2.5
3.3
5
12
12
15
3.3
5.0
15
15.00
15.00
15.00
8.33
6.67
15.00
15.00
15.00
8.33
10.00
6.67
20.0
20.0
8.0
100
100
100
150
150
100
100
100
150
150
150
100
100
150
76%
80%
84%
85%
85%
75%
78%
83%
86%
84%
86%
80%
82%
84%
Model
QBS038YD-A
QBS050YE-A
QBS075YG-A
QBS100YH-A †
QBS100YJ-A
QBS038ZD-A
QBS050ZE-A
QBS075ZG-A
QBS100ZH-A †
QBS120ZH-A †
QBS100ZJ-A
QBS066ZE-A †
QBS100ZG-A †
QBS120ZJ-A †
† Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
2.28"
(57.9mm)
MOUNTING INSERTS
M3X0.5 THROUGH 4PL
0.815"(20.7mm)
2
BOTTOM VIEW
3
5
0.450"(11.4mm)
6
0.300"(7.6mm)
7
0.150"(3.8mm)
8
0
-0.215"(-5.5mm)
-0.425"(-10.8mm)
-0.14"
(-3.6mm)
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
10.1
8.0
5.4
4.4
3.4
(49.0mm)
Pin
°C/W
°C/W
°C/W
°C/W
°C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
0.50"
(12.7mm)
1.930"
(1.8mm)
(1.0mm)
6PL
(4.6mm)
(50.8mm)
0.070"
DIA 0.040"
0.18"
2.000"
0
QBS
1.45"
(36.8mm)
2PL
0.600"(15.2mm)
4
1
DIA 0.062"
(1.6mm)
Tolerances
Function
1
2
3
4
5
6
7
8
-Vin
On/Off
+Vin
-V out
-Sense
Trim
+Sense
+V out
2
Inches:
.XX ± 0.020
.XXX ± .010
(Millimeters)
.X ± 0.5
.XX ± 0.25
Pin:
± 0.002
± 0.05
( Dimensions as listed unless otherwise specified.)
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip
TS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
8
All Units (Except SMS)
0.150” (3.8mm) Pin Length
9
All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3