RHOMBUS-IND T

MSDSL Transformer
Supplementary Insulation
Requirements of IEC950
Turns Ratio (10-7) : (1-4) Shorted 2+3, 8+9
2 : 1 +1%
Turns Ratio (1-3) : (2-4)
1 : 1 +1%
Parameter
Min.
1
Inductance 1-4 (shorted 2+3)
Inductance 10-7 (shorted 8+9)
Schematic Diagram
1
2
10
Typ.
7.0
28
Max.
13
52
Leakage Inductance 1-4
Shorted 2+3, 8+9, 10+7
15
Units
mH
mH
µH
Resistance pins (1-3)
0.46
ohms
3
8
Resistance pins (2-4)
0.46
ohms
2
9
Resistance pins (10-8)
1.10
ohms
Resistance pins (9-7)
1.10
ohms
4
7
Isolation (Hi-Pot) PRI - SEC
2400
VRMS
Insertion Loss at 100k
Per IEEE method, (22.1 ohm load)
Longitudinal Balance 20 - 200kHz
Per ITU method (L->M)
55
0.20
dB
15
dB
THD, Total Harmonic Distortion: 81 dB typ., 10kHz, 3.53Vrms, 22.1 ohm load,
100 ohm input ( shorted 2+3, 8+9).
1. Tested at 10 KHz & 100 mV
2. Tested at 100 KHz & 100 mV
10
9
8
7
6
.148
(3.75)
.079
(2.0)
.11
(2.8)
1
2
3
.148
(3.75)
TYP.
4
.787
(20.0)
5
.039
(1.00)
TYP.
.1.09
(27.7)
.854
(21.7)
MAX.
.81
(20.6)
.385
(9.77)
Suggested Solder Pad Layout
.012
(0.30)
TYP.
.827
(21.0)
.07
(1.80)
Physical Dimensions
inches (mm)
RHOMBUS P/N: T-1022G
CUST P/N:
DATE: 02/17/98
Rhombus
Industries Inc.
Transformers & Magnetic Products
FSCM No.
16714
NAME:
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971