SECOS SZMD24C

SZMD24C
100W, 24 V
Transient Voltage Suppressors
for ESD Protection
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
SOT-23
FEATURES
z
z
z
z
A
SOT-23 package for surface mount application
Protects 24V components
Protects two unidirectional line or one bi-direction line
Provides electrically is olated protection
L
3
3
C B
Top View
1
1
K
2
E
2
D
F
APPLICATIONS
z
z
z
z
z
Cellular Handsets and Accessories
Portable devices
Industrial Controls
Set -Top Box
Servers, Notebook, and Desktop PC
G
REF.
A
B
C
D
E
F
Millimeter
Min.
Max.
2.80
3.00
2.25
2.55
1.20
1.40
0.90
1.15
1.80
2.00
0.30
0.50
H
REF.
G
H
J
K
L
J
Millimeter
Min.
Max.
0.10 REF.
0.55 REF.
0.08
0.15
0.5 REF.
0.95 TYP.
1
3
Marking Code
2
KDQ
ABSOLUTE RATINGS (Tamb = 25°C )
Rating
Air contact
Contact discharge
ESD voltage
Per human body model
Total power dissipation on FR-5 Board (Note 1) @ TA=25℃
Junction and storage temperature range
Lead solder temperature – maximum (10 Second duration)
Symbol
Value
Units
PD
TJ, TSTG
TL
±15
±8
16
150
-55 ~ +150
260
kV
kV
kV
m/W
°C
°C
IEC 61000-4-2 (ESD)
Stresses exceeding Maximum Ratings may damage the device. Maximum Rating are stress ratings only. Functional operation above the Recommended
Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability.
1. FR-5 = 1.0*0.75*0.62 in.
ELECTRICAL CHARACTERISTICS
(Ratings at 25°C ambient temperature unless otherwise specified. VF = 0.9V at IF = 10mA)
IPP
VC (V)
VBR (V)
VRWM
IR(uA)
IT
PPK
@ Max IPP
(A)
Device
(V)
@ VRWM
@ IT (Note 2) (mA)
(W)*
SZMD24C
Max
24
Max
0.1
Min
28
mA
5.0
(Note 3)
(Note 3)
Max
43
Max
2.0
Max
100
C
(pF)
(Note 4)
Typ
18
Other voltages available upon request.
2. VBR is measured with a pulse test current IT at an ambient temperature of 25℃
3. Surge current waveform per Figure 3.
4. Measured at 1MHz 0V.
http://www.SeCoSGmbH.com/
01-June-2002 Rev. A
Any changes of specification will not be informed individually.
Page 1 of 2
SZMD24C
100W, 24 V
Transient Voltage Suppressors
for ESD Protection
Elektronische Bauelemente
RATINGS AND CHARACTERISTICS CURVES
Clamping Voltage vs. Peak Pulse Current
Power Derating Curve
110
Waveform
Parameters
tr = 8µs
td = 20µS
50
100
% of Rated Power or I PP
Clamping Voltage - VC (V)
60
40
30
20
80
70
60
50
40
30
20
10
10
0
0
1
2
0
3
0
Peak Pulse Current - IPP (A)
Wave form
Paramete rs:
tr = 8 s
td = 20 s
90
80
e
60
-t
50
40
td = I PP /2
30
20
10
0
0
5
10
15
Time (us)
http://www.SeCoSGmbH.com/
01-June-2002 Rev. A
50
75
100
125
150
Applications Information
100
70
25
Ambient Temperature - TA ( o C)
Pulse Waveform
110
Percent of I PP
90
20
25
30
Device Connection Options
The SZMD series is designed to protect one
bi-directional or two uni-directional data or l/O lines
operating at 24 volts.Connection options are as
follows:
‧Bidirectional:Pin 1 is connected to the data line and
pin 2 is connected to ground (Since the device lls
symmetrical,these conmtions may be re- Ver3ed).For
best results,the ground connection should be made
directly to a ground plane on the board.The path
length should be kept as short as possible to minimize
parasitic inductance-Pin 3 is not
connected. ‧Unidirectional:Data lines are connected
to pin1 and pin2.Pin 3 is connected to ground.For
best results,this pin should be connected directly to a
ground plane on the board.The path lengh should be
kept as short as possible to minimize parasitic
inductance. Circuit Board Layout Recommendations
for suppres- sion of ESD. Good circuit board layout is
critical for the suppression of fast rise-time transients
such as ESD.The following guidelines are
recommended (Refer to application note Sl99.01 for
more detailed information): ‧Place the TVS near the
input terminals or connec- tors to restrict transient
coupling. ‧Minimize the path length between the
TVS and the protected line. ‧Minimize all conductive
loops including power and ground loops. ‧The ESD
transient return path toground should be kept as short
as possible. ‧Never run critical signals near board
edges
‧Use ground planes whenever possib|e.
Any changes of specification will not be informed individually.
Page 2 of 2