SEMIKRON SBH3045

SBH 3020 ... SBH 3060
Type
Repetitive
peak
reverse
voltage
Surge peak
reverse
voltage
Max.
reverse
recovery
time
Max.
forward
voltage
Max.
forward
voltage
VRRM
V
VRSM
V
trr1)
ns
VF2)
V
VF3)
V
SBH 3020
20
20
-
0,43
0,6
SBH 3030
30
30
-
0,43
0,6
SBH 3040
40
40
-
0,43
0,6
SBH 3045
45
45
-
0,43
0,6
SBH 3050
50
50
-
0,53
0,7
High temperature schottky
barrier diodes
SBH 3060
60
60
-
0,53
0,7
Forward Current: 30 A
Symbol
Reverse Voltage: 20 to 60 V
Ta = 25 °C, unless otherwise specified
Axial Lead Diode
SBH 3020 ... SBH 3060
Preliminary Data
Features
Absolute Maximum Ratings
Conditions
Values
Unit
IFAV
R-load, 4), Ta = 50 °C
30
A
IFRM
f > 15 Hz, 4)
90
A
IFSM
half sinus-wave
Ta = 25 °C
700
A
2450
A²s
tp = 10 ms
tp = 8.3 ms
A
tp = 10 ms
• Max. solder temperature: 260°C
• Plastic material has UL
classification 94V-0
i2t
Tj
Operating junction temperature
-50 ... +175
°C
Typical Applications*
Tj
DC forward (bypass) mode 5)
-50 ... +200
°C
Tstg
Storage temperature
-50 ... +175
°C
• Designed as Bypass Diodes for Solar
Panels
• Protection application
Mechanical Data
• Plastic case: 8 x 7,5 [mm]
• Weight approx.: 2,4 g
• Terminals: plated terminals solderable
per MIL-STD-750
• Mounting position: any
• Standard packaging: 500 pieces per
ammo or 1000 pieces per reel
Footnotes
1)
IF = - A, IR = - A, IRR = - A
2) I = 5 A, T = 25 °C
F
j
3)
IF = 30 A, Tj = 25 °C
4)
Valid, if leads are kept at TA at a distance
of 0 mm from case
5)
Max. junction temperature Tj ≤175 °C in
reverse mode (VR = 80% VRRM) in reverse
mode, Tj≤ 200 °C in bypass mode
6)
Thermal resistance from junction to lead/
terminal at distance 0 mm from case
Ta = 25 °C
tp = 8.3 ms
A²s
Characteristics
Symbol
Conditions
min.
typ.
max.
Unit
Ta = 25 °C, unless otherwise specified
IR
Tj = 25 °C, VR = VRRM
IR
Tj = 100 °C, VR = VRRM
Cj
at 1 MHz and applied reverse voltage
of 4 V
-
pF
ERSM
L = 60 mH, Tj = 25 °C, inductive load
switched off
-
mJ
Rth(j-a)
4)
-
K/W
Rth(j-L)
6)
2.5
K/W
150
µA
mA
Diode
© by SEMIKRON
Rev. 2 – 06.05.2011
1
SBH 3020 ... SBH 3060
Fig.1: Forward characteristics (typical value)
Fig.2: Rated forward current vs. ambient temperature 1)
Fig.3: Thermal resistance versus distance from case
Case: 8 x 7,5 [mm]
2
Rev. 2 – 06.05.2011
© by SEMIKRON
SBH 3020 ... SBH 3060
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
© by SEMIKRON
Rev. 2 – 06.05.2011
3