ACE624 Technology Serial data control dual electronic volume Description The ACE624 is a dual channel electronic volume controlled with 2-wire serial data. The built-in reference circuit can compose of an electronic volume with less external parts. Features • • • Built-in reference circuit Control with serial data Volume 0 to -83dB (1dB/step), -∞ (Independent control is allowed in each channel) Low noise and low distortion VNO=5μVrms (ATT=-∞, JIS-A) THD=0.01% Typ. (V0=0.5Vrms, DIN-AUDIO) Absolute Maximum Ratings Symbol Parameter Ratings Unit Vcc Supply voltage 6.0 V Pd Power dissipation 625(p),440(FP) mW Topr Operating temperature -20 to +75 ℃ Tstg Storage temperature -55 to +125 ℃ Packaging Type SOP-8 VIN1 VIN2 VOUT1 VOUT2 GND VCC DATA CLOCK Pin No 1 2 3 4 5 6 7 8 Symbol Function VIN1 1-ch input pin VOUT1 1-ch output pin GND Ground pin DATA Control data input pin. Inputs data in synchronization with clock CLOCK Clock input pin for transferring serial data VCC Power supply pin. Stabilize the pin with decoupling capacitor VOUT2 2-ch output pin VIN2 1-ch input pin VER 1.2 1 ACE624 Technology Serial data control dual electronic volume Ordering information Selection Guide ACE624 XX + H Halogen - free Pb - free FM : SOP-8 Block Diagram System configuration VER 1.2 2 ACE624 Technology Serial data control dual electronic volume Electrical Characteristics (Vcc=5V, TA=25℃, unless otherwise noted.) Symbol Parameter Test conditions ICC ATT ATT Vim Vom Vno1 Vno2 THD CS Circuit current Maximum attenuation Attenuation error Maximum input voltage Maximum output voltage MIN。 TYP。 ATT= -∞ ATT=0 THD=1%,ATT= -6dB THD=1% ATT=0,Rg=0,JIS-A Output noise voltage ATT=-∞,Rg=0,JIS-A Total harmonic distortion f=1kHZ,Vo=0.5Vrms,ATT=0 Channel separation f=1kHZ,JIS-A -2.0 1.5 0.8 4 -90 0 1.7 1.3 4 5 0.01 -80 MAX。 UNIT 8 -80 2.0 mA dB dB Vrms Vrms µVrms µVrms % dB 10 0.05 -70 Relationship Between Data and Clock Clock D0 D1 D2 D3 D8 D9 D10 Data Latch singal "H" Reads data singal at the rising edge of clock singa Reads data singal at the falling edge of clock singa DC Characteristics of digital block Symbol Vil Vih Iil Iih Parameter "L" level input voltage "H" level input voltage "L" level input current "H" level input current Test conditions Data, clock pin Vi=0 Vi=5V UNIT Limits MIN. TYP. MAX. 0 0.2Vcc V 0.8Vcc Vcc V -10 10 uA 10 uA VER 1.2 3 ACE624 Technology Serial data control dual electronic volume AC Characteristics of digital block Symbol tcr tWHC tWLC tr tf tSD tHD Parameter Test conditions Min. 4 1.6 1.6 Cycle time of clock Pulse width of clock ("H" level) Pulse width of clock ("L" level) Clock rising time Clock falling time Data setup time Data hold time 0.8 0.8 Unit Limits Typ. Max. us us us 0.4 us 0.4 us us us Clock and Data Timing Data input format D0 D1 0/1 0/1 D2 D3 D4 D5 D6 VOLUME D7 D8 D9 D10 1 1 0:Both channels at a time 1:A channel at a time 0:1CH 1:2CH VER 1.2 4 ACE624 Technology Serial data control dual electronic volume Volume Code ATT1 0 dB -4 dB -8 dB -12 dB -16 dB -20 dB -24 dB -28 dB -32 dB -36 dB -40 dB -44 dB -48 dB -52 dB -56 dB -60 dB -64 dB -68 dB -72 dB -76 dB -80 dB -∞ D2 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 D3 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 D4 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 D5 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 D6 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ATT1 0 dB D7 1 D8 1 -1 dB -2 dB -3 dB 0 1 0 1 0 0 VER 1.2 5 ACE624 Technology Serial data control dual electronic volume Application Example VER 1.2 6 ACE624 Technology Serial data control dual electronic volume Packing Information SOP-8 VER 1.2 7 ACE624 Technology Serial data control dual electronic volume Notes ACE does not assume any responsibility for use as critical components in life support devices or systems without the express written approval of the president and general counsel of ACE Electronics Co., LTD. As sued herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and shoes failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ACE Technology Co., LTD. http://www.ace-ele.com/ VER 1.2 8