AIMTEC AMSRL-7805-NZ

Series AMSRL-78-NZ
Up to 7.5 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
•
•
•
•
•
Switching Regulator
Low Noise
Wide Input
Non-Isolated
Adjustable Output Voltage
Thermal Shutdown
SMD Package
Efficiency Up To 96%
Remote On/Off
Short Circuit Protection
High MTBF
RoHS Compliant
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Efficiency
Vin Max
(%)
Efficiency
Vin Min
(%)
4.5-28
6-28
14-28
17-28
3.3
5
12
15
500
500
500
500
75
81
90
92
90
94
95
96
AMSRL-783.3-NZ
AMSRL-7805-NZ
AMSRL-7812-NZ
AMSRL-7815-NZ
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Start up time
On/Off Control
Quiescent Current
Nominal
Typical
Maximum
Units
See Models table above
2
ON –open or 1.5V < Vc < 6V ; OFF –GND or 0V < VC < 1V , 2uA
Vin = min to max at 0% load
10
ms
mA
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Thermal shutdown
Dynamic load stability
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Voltage adjustment range (V adj)
Conditions
Typical
At 100% load
Maximum
±3
Continuous, hiccup mode
Auto-Recovery
160
±75
±0.5
±1
0.02
25
1.8-5.5
2.5-8.0
4.5-13.5
4.5-15.5
Internal IC Junction
10-100% load
Vin=(LL-HL) at full load
10-100% load
-40°C to +85°C ambient
20MHz Bandwidth
3.3
5
12
15
Maximum Capacitive Load
Units
%
ºC
mV
%
%
%/oC
mV p-p
VDC
1000
uF
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
www.aimtec.com
F 051e R8.B
Conditions
Typical
100% load
With derating above 71 ºC
1.4
Maximum
Units
100
MHz
o
C
o
C
o
C
95
% RH
-40 to +85
-55 to +125
Free Air Convection
Plastic (UL94-V0)
2.3
Tel: +1 514 620 2722
1 of 3
g
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSRL-78-NZ
Up to 7.5 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
Turn on Transient process time
Off idle current
Typical
Maximum
Units
0.60 x 0.47 x 0.29 Inches 15.24 x 11.82 x 7.25 mm
> 2 000 000 hrs (MIL-HDBK-217F, Ground Benign, t=+25 oC)
1.5mm from case for 10 sec
300
50
30
o
C
us
uA
Pin Out Specifications
Single
+V input
+V output
V adj
Ground
Ground
ON/OFF
Pin
1
5
6
7
9
10
Dimensions
Side View
15.24
(0.60)
Front View
A
7.25 7.00
(0.29) (0.28)
7.25
(0.29)
0.25
(0.01)
2.54
(0.10)
Top View
1.00 1.80
(0.04) (0.07)
9
10
A
2.54
(0.10)
7
0.25
(0.01)
6
11.82 8.50
(0.47) (0.34)
5.00º angle
1
1.13
(0.44)
5
Derating
Free Air Convection
71 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R8.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSRL-78-NZ
Up to 7.5 Watt | DC-DC Converter
Application Circuit
V Input
10uF
50V
1
C1
5
AMSRL-78XX-NZ
10
7&9
ON/OFF
6
V Output
R1
C5
470 uf
C2
C3
100uF
20V
R2
Ground
Ground
Model Number
C2 (uF)
AMSRL-783.3-NZ
AMSRL-7805-NZ
AMSRL-7812-NZ
AMSRL-7815-NZ
22
22
10
10
It is recommended that ceramic capacitors are used for C2 & C3.
It is recommended to install C3 to improve performance.
C1 & C2 are required and should be installed as close to the converter as possible
Model Number
Nominal
Output (V)
AMSRL-783.3-NZ
3.3
AMSRL-7805-NZ
5
AMSRL-7812-NZ
12
AMSRL-7815-NZ
15
Vout Adjusted Up
R2 (KΩ)
Vout Adjusted Down
R1 (KΩ)
If it is needed to adjust the output voltage higher or lower than the converter’s nominal value use the equations in the table
above to calculate appropriate resistor values, insuring that the voltage is within the adjustment range for the converter used.
If no voltage adjustment is needed connect a 470uF ceramic capacitor from pin 6 to ground.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 051e R8.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only