AXTAL AXLGS635F

Specification
Type :
Issue: 02
Date: 2005-07-15
AXLGS635F
Langasite (LGS) SMD Crystal Resonator Unit
Parameter
min. typ. max. Unit
Frequency range
Standard frequencies
Crystal cut
Overtone
Load capacitance CL
Adjustment tolerance
Frequency offset
Frequency stability
vs. temperature
in operation temperature range
long term (aging rate)
Resonance resistance Rr
Motional capacitance C1
Static capacitance C0
Drive level
Drive level dependence (DLD)
Unwanted responses
Insulation resistance
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Can height H
marking
10
29
Rotated Y
1
See ordering code
-20
+20
-20
0
40
+52
+50
5
15
150
7
100
According to
2*Rr
500
-40
+85
-55
+125
SMD 6x3.5 (4-pad)
1,0
Part no.
Frequency
Date Code
Tape & reel
Condition
MHz
MHz
pF
ppm
ppm
ppm
ppm
°C
ppm
Ω
fF
pF
µW
MΩ
°C
°C
30 pF if not specified
@ 25°C
Overall (Note 1)
See chart on page 2
IEC 60444-6
f0 ~ f0+500 kHz
100 V DC
IEC 61837 DCC-4/06
mm
TBD
IEC 60286-3
Packing
Notes:
1. Overall frequency stability = initial tolerance + temp. stability + aging (1st year)
2. Terminology and test conditions are according to IEC standard IEC60122-1, unless otherwise stated
3. Measurement technique according to IEC 60444-5 or equivalent
Ordering Code:
Model (Specification)
AXLGS635F
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Load capacitance* Frequency
[pF]
[MHz]
20
10.000
*Series resonance: “S”
AXLGS635F
page 1(2)
www.axtal.com
fon: +49 (6261) 9398-34
fax: +49 (6261) 9398-36
E-mail: [email protected]
Enclosure drawing
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
IEC 60122-1
clause ...
4.5
4.6
4.8.2
Solderability
Resistance to
soldering heat
Shock
2-20
4.8.3
2-27
4.8.8
Free fall
2-32
4.8.9
Vibration,
sinusoidal
2-6
4.8.7
Endurance tests
- ageing
- extended aging
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
4.9.1
4.9.2
Test conditions
Enclosure styles as in IEC
60122-3, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per 2 axes
5000g, 0.3 ms half-sine
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 1 octave per min.
1 hour per axes
10 Hz ~ 2000 Hz, 20g.
30 days @ 85°C
1000h, 2000h, 8000h @85°C
AXLGS635F
page 2(2)
www.axtal.com
fon: +49 (6261) 9398-34
fax: +49 (6261) 9398-36
E-mail: [email protected]