CHENMKO DB103-SPT

DB101-SPT
CHENMKO ENTERPRISE CO.,LTD
THRU
SINGLE-PHASE GLASS PASSIVATED
SILICON SURFACE MOUNT BRIDGE RECTIFIER
VOLTAGE RANGE 50 - 1000 Volts CURRENT 1.0 Ampere
DB107-SPT
FEATURES
*
*
*
*
*
Reliable low cost construction utilizing molded
Surge overload rating of 50 Amperes peak
Glass passivated device
Ideal for printed circuit board
Polarity symbols molded on body
DB-S
0.310(7.9)
0.290(7.4)
0.255(6.5)
0.245(6.2)
MECHANICAL DATA
Case: JEDEC DB-S molded plastic
Terminals: Solder plated, solderable per MIL-STD-750,
Method 2026
Mounting position: Any
Polarity: Indicated by cathode band
Weight: 1.0 gram
0.013(.330)
0.003(.076)
0.042(1.1)
0.038(1.0)
0.009
(0.23)
0.410(10.4)
0.06(1.524)
0.360(9.4)
0.04(1.016)
0.365(9.3)
0.355(9.0)
0.135(3.4)
0.115(2.9)
0.205(5.2)
0.195(5.0)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 HZ, resistive or inductive load.
For capacitive load, derate current by 20%.
DB-S
Dimensions in inches and (millimeters)
MAXIMUM RATINGES ( At TA = 25oC unless otherwise noted )
RATINGS
SYMBOL
DB101-SPT DB102-SPT DB103-SPT DB104-SPT DB105-SPT DB106-SPT DB107-SPT
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum Average Forward Rectified Current TA = 40oC
IO
1.0
Amps
IFSM
50
Amps
TJ, TSTG
-55 to +150
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Operating and Storage Temperature Range
o
C
ELECTRICAL CHARACTERISTICS ( At TA = 25oC unless otherwise noted )
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 1.0 A DC
Maximum Reverse Current at rated
SYMBOL
DB101-SPT DB102-SPT DB103-SPT DB104-SPT DB105-SPT DB106-SPT DB107-SPT
UNITS
VF
1.1
Volts
5.0
uAmps
0.5
mAmps
@ TA = 25oC
IR
DC blocking Voltage per element
NOTES : Suffix " -S " Surface Mount for Dip Bridge.
@ TA = 125oC
2002-5
RATING CHARACTERISTIC CURVES ( DB101-SPT THRU DB107-SPT )
1.00
0.75
0.50
Single
Half Wave 60HZ
Resistive or
Inductive Load
0.25
0
0
20
40
60
80
100
120
140
160
PEAK FORWARD SURGE CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
FIG. 1 - TYPICAL FORWARD CURRENT DERATING CURVE
1.25
FIG. 2 - MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
70
60
8.3 ms Single Half
Sine-Wave (JEDEC Method)
50
40
30
20
10
0
0
2
AMBIENT TEMPERATURE, ( oC )
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARCTERISTICS
20
40
60 80 100
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
6 8 10
10
20
10
TJ = 25oC
1.0
4
NUMBER OF CYCLES AT 60HZ
0.1
PULSE WIDTH=300uS
1% DUTY CYCLE
.01
4
TJ = 100oC
1.0
0.4
0.1
.04
TJ = 25oC
.01
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.6
1
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)