CHENYI GP30A

GP30A
THRU
GP30M
Shanghai Lunsure Electronic
Technology Co.,Ltd
Tel:0086-21-37185008
Fax:0086-21-57152769
Features
•
•
•
•
3.0 Amp Glass
Passivated Junction
Rectifiers
50 to 1000 Volts
High temperature metallurgically bonded construction
Glass passivated cavity-free junction, Plastic Case
3.0 amperes operation at TA=55OC and with no
thermal runaway.
Typical IR less than 0.1uA
DO-201AD
Maximum Ratings
•
•
•
Operating Temperature: -55OC to +150 OC
Storage Temperature: -55OC to +150 OC
Typical Thermal Resistance: 20OC/W Junction to Lead
Part Number
GP30A
GP30B
GP30D
GP30G
GP30J
GP30K
GP30M
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
35V
70V
140V
280V
420V
560V
700V
50V
100V
200V
400V
600V
800V
1000V
D
A
Cathode
Mark
B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Maximum Average
Forward Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
GP30A -30B
GP30D -30M
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Typical Junction
Capacitance
IF(AV)
3.0 A
TA = 55OC
IFSM
125A
8.3ms, half sine
C
DIMENSIONS
VF
1.2V
1.1V
IR
5.0uA
100uA
TA=25OC
TA=150 OC
CJ
40pF
Measured at
1.0MHz, VR=4.0V
I FM = 3.0A;
DIM
A
B
C
D
INCHES
MIN
----.048
1.000
www.cnelectr.com
MAX
.370
.250
.052
---
MM
MIN
----1.20
25.40
MAX
9.50
6.40
1.30
---
NOTE
GP30A thru GP30M
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
3.0
6
4
2.5
2
Amps
25OC
1
2.0
.6
1.5
Amps
.4
1.0
.2
.5
.1
Single Phase, Half Wave
0 60Hz Resistive or Inductive Load
50
75
100
125
0
.06
.04
O
.02
.01
.4
1.0
1.2
1.4
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
.8
.6
Figure 3
Junction Capacitance
100
60
40
20
pF
150
175
C
Average Forward Rectified Current - Amperes versus
Ambient Temperature - OC
TJ =25°C
10
6
4
2
1
.1
.2
.4
1
2
4
Volts
10
20
40
100 200
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.cnelectr.com
400
1000
GP30A thru GP30M
Figure 4
Peak Forward Surge Current
300
250
200
150
Amps
100
50
0
1
2
4
6
10 20
8
Cycles
40
60 80 100
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
www.cnelectr.com