CLAIREX CLI300

CLI300 Series
®
IRED - Photosensor
Photointerrupters
features
• rugged plastic package
• hermetically sealed components
• various output configurations
description
The CLI300 series each consist of
an IRED and photosensor mounted
in a black plastic housing. Each
device has 12 inch leads and two
holes for bracket mounting in any
position. Alternate output circuits
and lead lengths are available. For
assistance, call Clairex.
Clairex
Technologies, Inc.
March, 2005
absolute maximum ratings (TA = 25°C unless otherwise stated)
storage and operating temperature................................................ -55°C to +100°C
IRED
continuous forward current ............................................................................. 60mA
reverse voltage .................................................................................................... 5V
continuous power dissipation(1) .................................................................... 100mW
CLI325, CLI355 and CLI375 OUTPUT
collector-emitter voltage..................................................................................... 30V
(2)
continuous collector current ......................................................................... 50mA
continuous power dissipation(3) .................................................................... 200mW
(4)
CLI385 OUTPUT
supply voltage.................................................................................................... 18V
sink current ..................................................................................................... 25mA
continuous power dissipation(3) .................................................................... 200mW
notes:
1. Derate linearly 1.07mW/°C from 25°C free air temperature to TA = +100°C.
2. 200mA when pulsed at 1.0ms, 10% duty cycle.
3. Derate linearly 2.13mW/°C from 25°C free air temperature to TA = +100°C.
4. Buffer output. Output is LOW when input radiation is below threshold level.
electrical characteristics (TA = 25°C unless otherwise noted)
symbol parameter
Input IRED, all devices
VF
IR
Forward voltage
Reverse current
min
typ
max
units
test conditions
-
-
1.5
10
V
µA
IF = 10mA
VR = 5V
-
-
100
nA
VCE = 10V, Ee = 0
-
-
50
nA
VCE = 10V, Ee = 0
4
-
-
16
12
V
mA
VCC = 4.5V – 16V
Output CLI325, CLI355
ID
Collector-emitter dark current
Output CLI375
ID
Collector-emitter dark current
Output CLI385
VCC
ICC
Supply voltage
Supply current
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900

1301 East Plano Parkway
Fax: 972-265-4949
Revised 3/16/06
Plano, Texas 75074-8524
www.clairex.com
CLI300 Series
®
IRED - Photosensor
Photointerrupters
Clairex
Technologies, Inc.
electrical characteristics (TA = 25°C unless otherwise noted)
symbol parameter
Coupled CLI325
min
typ
max
units
test conditions
3.0
-
50
1.2
-
mA
V
µsec
IF = 10mA, VCE = 5V
IF = 10mA, IC = 4mA
IC = 2.0mA, VCC=10V, RL = 100Ω
12.0
3.2
-
300
1.2
0.4
-
V
mA
V
V
µsec
IF = 10mA, IC = 4mA
IF = 10mA, VCC = 5V
IF = 10mA, VCC = 5V
Ee = 0
IC = 2.0mA, VCC = 10V, RL =100Ω
Saturation voltage
0.5
Sensor light current
1.0
Output rise and fall time
5.0
Coupled CLI385 (VCC = 5V unless otherwise noted)
VOL
Low level output voltage
0.4
IOH
High level output leakage
5.0
IF+
IRED positive going threshold(7)
10
IF+/IF Hysteresis ratio
1.2
tr, tf
Output rise and fall time
75
tPLH
Propagation delay, low to high
6.0
tPHL
Propagation delay, high to low
6.0
note: 6. IF = 0 equates to light path being blocked by opaque object.
7. Minimum current applied to IRED to cause output to change state.
V
mA
µsec
IF = 20mA, IC = 1mA
IF = 10mA, VCE = 5V
IC = 2.0mA, VCC = 10V, RL =100Ω
IL
VCE(sat)
tr, tf
Sensor light current
Saturation voltage
Output rise and fall time
Coupled CLI355
VCE(sat)
IL
VO
VOFF
tr, tf
Saturation voltage
Sensor light current
Voltage output across 270Ω resistor
Voltage output across 270Ω resistor
Output rise and fall time
Coupled CLI375
VCE(sat)
IL
tr, tf
V
µA
mA
IOL = 15mA, IF = 0(6)
IF = 15mA, VOH = 18V
ns
µs
µs
IF = 0(6) or 15mA,
f = 10kHz, Duty Cycle = 50%,
RL = 240Ω, CL = 15pF
Schematic Configurations
RED
CLI325
BLUE
RED
CLI355
BLUE
RED
CLI375
BLUE
RED
CLI385
*
BLUE
GREEN
GREEN
330 ohms
BLACK
YELLOW
BLACK
270 ohms
YELLOW
BLACK
YELLOW
BLACK
YELLOW
* The CLI385 features an open collector, buffer, digital output. Other output functions such as inverter and
internal 10K pull-up are available. Obtain a copy of the CLL Series data sheet from our website at
www.clairex.com to see other available output configurations.
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Plano, Texas 75074-8524
www.clairex.com
