The 4CPL1000C tube is designed for switch tube, pulse modulator, or voltage regulator service. It will pass anode current up to 8 amperes for pulses up to 100 microseconds duration, and derated values of anode current at longer pulse durations. This tube is designed for immersion in cooling a liquid dielectric and can dissipate 1,000 watts. In air with proper cooling, plate dissipatin is 300 watts. The 4CPL1000C has an integral mounting flange. This tube is rated to operate at an anode potential up to 15 kVdc when immersed in the recommended coolant. When immersed, the rating is not altitude dependant. Class of Operation Characteristics Plate Dissipation (Max.) Screen Dissipation (Max.) Grid Dissipation (Max.) Frequency for Max. rating (CW) Amplification Factor Filament/Cathode Voltage Current Capacitance Input Output Feedthrough Capacitance Input Output Feedthrough Cooling Base Air Socket Air Chimney Boiler Length Diameter Weight Maximum Ratings Type of Service Plate Voltage (Volts) Plate Current (Amps) Pulse modulator or switch tube 15,000 8.0 Oxide Coated 6.3 Volts 4.9 Amps pf pf pf pf pf pf Liquid or Forced Air Special with Solder Terms ------2.68 in; 68.07 mm 2.75 in; 69.85 mm --- T ypical Operation Plate Screen Voltage Voltage (Volts) (Volts) 7,000 1,000 Watts 15 Watts 2 Watts --- MHz Plate Current (Amps) Drive Output Power Power (Watts) (kiloWatts) 700 The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For information on this and other CPI products, visit our website at: www.cpii.com, or contact: CPI MPP Division, Eimac Operations, 607 Hansen Way, Palo Alto, CA 94303 telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : [email protected] CPI | 4CPL1000C CPI | 4CW50,000J 4CPL1000C