DELTA PMC-12V050W1AA

Panel Mount Power Supply
12V 50W 1 Phase
PMC-12V050W1AA
PMC-12V050W1AA
50Watts
Total Power: 50Watts
Input Voltage: 85-264Vac
# of Output: Single
Model number
Reference no.
OUTPUT (DC)
PMC-12V050W1AA
EOE11010186
Output power
Output voltage range
Output current
50W
11-14V
4.17A (50W max.)
PARD (20MHz)
< 100mVpp (@ nominal values)
Start-up time
Hold-up time
Rise time
Line regulation
Load regulation
< 2500ms @ 100% load (25°C) and typical line input
> 15ms @ 115Vac, > 80ms @ 230Vac with 50W load (25°C)
< 30ms @ 100% load (25°C)
< 0.5% typical (@ 85 - 264Vac input, 100% load)
< 1% typical (@ 85 - 264Vac input, 0 to 100% load)
INPUT (AC)
Input voltage range
Input frequency
Max. input current
Inrush current limitation I²t
(+25°C) typ.
Efficiency
Leakage current
85 - 264Vac
47 - 63Hz
1.5A max. (1.1 max. @ 115Vac, 0.7A max. @ 230Vac)
< 30A @ 115Vac & 60A @ 230Vac
Case cover
Aluminium (AL1100)
Dimensions (L x W x H)
128mm x 97mm x 38mm
Unit weight / box
0.260kg
MTBF
> 700,000 hrs
Noise
Cooling
Input / output terminal
Sound pressure level (SPL) < 40dBA
Convection
Terminal block 5 pin rated 300V/20A
Input / output wire
Shock proof
Vibration
AWG22-14
IEC60068-2-27
IEC60068-2-6
MECHANICAL DESIGN
> 83% @ 115Vac & > 84% @ 230Vac
< 1mA @ 240Vac
Special Features
•
•
•
•
•
•
•
•
•
Full aluminum casing for
lightweight and corrosion
resistant handling
Universal AC input
Overload protection
Thermal protection
MTBF: > 700,000 hrs.
Efficiency > 84%
Expected life time: 10 years
2 years warranty
RoHS compliant
Panel Mount Power Supply
12V 50W 1 Phase
PMC-12V050W1AA
MECHANICAL DRAWING
Delta Electronics (Thailand)
Public Company Limited
909 Moo 4, E.P.Z.,
Bangpoo Industrial Estate,
Tambon Prakasa, Amphur
Muang Samutprakarn,
Samutprakarn 10280, Thailand
Tel: +662 709 2800
Fax: +662 709 2827
E-mail: [email protected]
www.deltaenergysystems.com
PMC
L
N
SAFETY / ENVIRONMENTAL
EMC / Emissions
FCC Title 47, Class B/EN55022;CISPR22, Class B
Immunity
EN 61000-4-2, 1995; EN61000-4-3, 1998; EN61000-4-4, 1995;
IEC61000-4-5, 1995; EN61000-4-6, 1996; EN61000-4-8 or
IEC61000-4-12 or IEEE C62.41; EN61000-3-2, 1994
UR/cUR recognized to UL60950-1 and CSA C22.2 No.60950-1;
CB test certificate and report to IEC60950-1;
CE (EMC and low voltage directive), TUV
Safety standard
Voltage dips
Galvanic isolation
Operating temperature
Storage temperature
Operating humidity
Note (*)
Conform to EN61000-4-11
Input to output: 3KVac;
Input to ground: 1.5KVac;
Output to ground: 0.5KVac
-10°C to +70°C *
-25°C to +85°C
< 95% RH non-condensing
* Operation to 70°C possible with a linear derating to half power
from 50°C to 70°C