ELPIDA EBJ42HE8BAFA

DATA SHEET
4GB Registered DDR3 SDRAM DIMM
EBJ42HE8BAFA (512M words × 72 bits, 4 Ranks)
Specifications
Features
• Density: 4GB
• Organization
 512M words × 72 bits, 4 ranks
• Mounting 36 pieces of 1G bits DDR3 SDRAM sealed
in FBGA
• Package: 240-pin socket type dual in line memory
module (DIMM)
 PCB height: 30.5mm (max.)
 Lead pitch: 1.0mm
 Lead-free (RoHS compliant)
• Power supply: VDD = 1.5V ± 0.075V
• Data rate: 1066Mbps/800Mbps (max.)
• Eight internal banks for concurrent operation
(components)
• Interface: SSTL_15
• Burst lengths (BL): 8 and 4 with Burst Chop (BC)
• /CAS Latency (CL): 6, 7, 8
• /CAS write latency (CWL): 5, 6
• Precharge: auto precharge option for each burst
access
• Refresh: auto-refresh, self-refresh
• Refresh cycles
 Average refresh period
7.8µs at 0°C ≤ TC ≤ +85°C
3.9µs at +85°C < TC ≤ +95°C
• Operating case temperature range
 TC = 0°C to +95°C
• Double-data-rate architecture; two data transfers per
clock cycle
• The high-speed data transfer is realized by the 8 bits
prefetch pipelined architecture
• Bi-directional differential data strobe (DQS and /DQS)
is transmitted/received with data for capturing data at
the receiver
• DQS is edge-aligned with data for READs; centeraligned with data for WRITEs
• Differential clock inputs (CK and /CK)
• DLL aligns DQ and DQS transitions with CK
transitions
• Commands entered on each positive CK edge; data
and data mask referenced to both edges of DQS
• Data mask (DM) for write data
• Posted /CAS by programmable additive latency for
better command and data bus efficiency
• On-Die-Termination (ODT) for better signal quality
 Synchronous ODT
 Dynamic ODT
 Asynchronous ODT
• Multi Purpose Register (MPR) for temperature read
out
• ZQ calibration for DQ drive and ODT
• Programmable Partial Array Self-Refresh (PASR)
• /RESET pin for Power-up sequence and reset
function
• SRT range:
 Normal/extended
 Auto/manual self-refresh
• Programmable Output driver impedance control
• 1 piece of registering clock driver and 1 piece of
serial EEPROM (256 bytes EEPROM) for Presence
Detect (PD).
• Class B temperature sensor functionality with
EEPROM
Note: Warranty void if removed DIMM heat
spreader.
Document No. E1412E20 (Ver. 2.0)
Date Published December 2008 (K) Japan
Printed in Japan
URL: http://www.elpida.com
Elpida Memory, Inc. 2008
EBJ42HE8BAFA
Ordering Information
Part number
Data rate
Mbps(max.)
Component
1
JEDEC speed bin*
(CL-tRCD-tRP)
EBJ42HE8BAFA-AE-E
1066
DDR3-1066F (7-7-7)
EBJ42HE8BAFA-8C-E
800
DDR3-800E (6-6-6)
Note: 1. Module /CAS latency = component CL + 1.
Data Sheet E1412E20 (Ver. 2.0)
2
Package
240-pin DIMM
(lead-free)
Contact
pad
Gold
Mounted devices
EDJ1108BASE-DG-E
EDJ1108BASE-DJ-E
EDJ1108BASE-AE-E
EDJ1108BASE-DG-E
EDJ1108BASE-DJ-E
EDJ1108BASE-AE-E
EDJ1108BASE-AG-E
EDJ1108BASE-8A-E
EDJ1108BASE-8C-E
EBJ42HE8BAFA
Pin Configurations
Front side
1 pin
121 pin
48 pin 49 pin
120 pin
168 pin 169 pin
240 pin
Back side
Pin No.
Pin name
Pin No.
Pin name
Pin No.
Pin name
Pin No.
Pin name
1
VREFDQ
61
A2
121
VSS
181
A1
2
VSS
62
VDD
122
DQ4
182
VDD
3
DQ0
63
CK1
123
DQ5
183
VDD
4
DQ1
64
/CK1
124
VSS
184
CK0
5
VSS
65
VDD
125
DM0/TDQS9
185
/CK0
6
/DQS0
66
VDD
126
NU/ /TDQS9
186
VDD
7
DQS0
67
VREFCA
127
VSS
187
/EVENT
8
VSS
68
Par_In
128
DQ6
188
A0
9
DQ2
69
VDD
129
DQ7
189
VDD
10
DQ3
70
A10(AP)
130
VSS
190
BA1
11
VSS
71
BA0
131
DQ12
191
VDD
12
DQ8
72
VDD
132
DQ13
192
/RAS
13
DQ9
73
/WE
133
VSS
193
/CS0
14
VSS
74
/CAS
134
DM1/TDQS10
194
VDD
15
/DQS1
75
VDD
135
NU/ /TDQS10
195
ODT0
16
DQS1
76
/CS1
136
VSS
196
A13
17
VSS
77
ODT1
137
DQ14
197
VDD
18
DQ10
78
VDD
138
DQ15
198
/CS3
19
DQ11
79
/CS2
139
VSS
199
VSS
20
VSS
80
VSS
140
DQ20
200
DQ36
21
DQ16
81
DQ32
141
DQ21
201
DQ37
22
DQ17
82
DQ33
142
VSS
202
VSS
23
VSS
83
VSS
143
DM2/TDQS11
203
DM4/TDQS13
24
/DQS2
84
/DQS4
144
NU/ /TDQS11
204
NU/ /TDQS13
25
DQS2
85
DQS4
145
VSS
205
VSS
26
VSS
86
VSS
146
DQ22
206
DQ38
27
DQ18
87
DQ34
147
DQ23
207
DQ39
28
DQ19
88
DQ35
148
VSS
208
VSS
29
VSS
89
VSS
149
DQ28
209
DQ44
30
DQ24
90
DQ40
150
DQ29
210
DQ45
31
DQ25
91
DQ41
151
VSS
211
VSS
32
VSS
92
VSS
152
DM3/TDQS12
212
DM5/TDQS14
33
/DQS3
93
/DQS5
153
NU/ /TDQS12
213
NU/ /TDQS14
34
DQS3
94
DQS5
154
VSS
214
VSS
35
VSS
95
VSS
155
DQ30
215
DQ46
36
DQ26
96
DQ42
156
DQ31
216
DQ47
Data Sheet E1412E20 (Ver. 2.0)
3
EBJ42HE8BAFA
Pin No.
Pin name
Pin No.
Pin name
Pin No.
Pin name
Pin No.
Pin name
37
DQ27
97
DQ43
157
VSS
217
VSS
38
VSS
98
VSS
158
CB4
218
DQ52
39
CB0
99
DQ48
159
CB5
219
DQ53
40
CB1
100
DQ49
160
VSS
220
VSS
41
VSS
101
VSS
161
DM8/TDQS17
221
DM6/TDQS15
42
/DQS8
102
/DQS6
162
NU/ /TDQS17
222
NU/ /TDQS15
43
DQS8
103
DQS6
163
VSS
223
VSS
44
VSS
104
VSS
164
CB6
224
DQ54
45
CB2
105
DQ50
165
CB7
225
DQ55
46
CB3
106
DQ51
166
VSS
226
VSS
47
VSS
107
VSS
167
NC
227
DQ60
48
VTT
108
DQ56
168
/RESET
228
DQ61
49
VTT
109
DQ57
169
CKE1
229
VSS
50
CKE0
110
VSS
170
VDD
230
DM7/TDQS16
51
VDD
111
/DQS7
171
A15
231
NU/ /TDQS16
52
BA2
112
DQS7
172
A14
232
VSS
53
/Err_Out
113
VSS
173
VDD
233
DQ62
54
VDD
114
DQ58
174
A12
234
DQ63
55
A11
115
DQ59
175
A9
235
VSS
56
A7
116
VSS
176
VDD
236
VDDSPD
57
VDD
117
SA0
177
A8
237
SA1
58
A5
118
SCL
178
A6
238
SDA
59
A4
119
SA2
179
VDD
239
VSS
60
VDD
120
VTT
180
A3
240
VTT
Data Sheet E1412E20 (Ver. 2.0)
4
EBJ42HE8BAFA
Pin Description
Pin name
Function
A0 to A15
Address input
Row address
Column address
A10 (AP)
Auto precharge
A0 to A13
A0 to A9
A12 (/BC)
Burst chop
BA0, BA1, BA2
Bank select address
DQ0 to DQ63
Data input/output
CB0 to CB7
Check bit (Data input/output)
/RAS
Row address strobe command
/CAS
Column address strobe command
/WE
Write enable
/CS0 to /CS3
Chip select
CKE0, CKE1
Clock enable
CK0, CK1
Clock input
/CK0, /CK1
Differential clock input
DQS0 to DQS8, /DQS0 to /DQS8
Input and output data strobe
TDQS9 to TDQS17, /TDQS9 to /TDQS17
Termination data strobe
DM0 to DM8
Input mask
SCL
Clock input for serial PD
SDA
Data input/output for serial PD
SA0, SA1, SA2
Serial address input
VDD
Power for internal circuit
VDDSPD
Power for serial EEPROM
VREFCA
Reference voltage for CA
VREFDQ
Reference voltage for DQ
VSS
Ground
VTT
Termination Voltage
/RESET
Set DRAM to known state
ODT0, ODT1
ODT control
Par_In
Parity bit for the Address and Control bus
/Err_Out
Parity error found on the Address and Control bus
/Event
Temperature event pin
NC
No connection
NU
Not usable
Data Sheet E1412E20 (Ver. 2.0)
5
EBJ42HE8BAFA
Serial PD Matrix
Byte No. Function described
0
Number of serial PD bytes written/SPD
device size/CRC coverage
Bit7 Bit6
Bit5
Hex
Bit4 Bit3 Bit2 Bit1 Bit0 value
Comments
1
0
1
176/256/0-116
0
0
0
1
0
92H
1
SPD revision
0
0
0
1
0
0
0
0
10H
Revision 1.0
2
Key byte/DRAM device type
0
0
0
0
1
0
1
1
0BH
DDR3 SDRAM
3
Key byte/module type
0
0
0
0
0
0
0
1
01H
Registered
4
SDRAM density and banks
0
0
0
0
0
0
1
0
02H
1G bits, 8 banks
5
SDRAM addressing
0
0
0
1
0
0
0
1
11H
14 rows, 10 columns
6
Module nominal voltage, VDD
0
0
0
0
0
0
0
0
00H
1.5V
7
Module organization
0
0
0
1
1
0
0
1
19H
4 ranks/×8 bits
8
Module memory bus width
0
0
0
0
1
0
1
1
0BH
72 bits/ECC
9
Fine timebase (FTB) dividend/divisor
0
1
0
1
0
0
1
0
52H
5/2
10
Medium timebase (MTB) dividend
0
0
0
0
0
0
0
1
01H
1
11
Medium timebase (MTB) divisor
0
0
0
0
1
0
0
0
08H
8
12
SDRAM minimum cycle time
(tCK (min.))
-AE
0
0
0
0
1
1
1
1
0FH
1.875ns
0
0
0
1
0
1
0
0
14H
2.5ns
-8C
13
Reserved
0
0
0
0
0
0
0
0
00H
—
14
SDRAM /CAS latencies supported, LSB
-AE
0
0
0
1
1
1
0
0
1CH
CL = 6, 7, 8
0
0
0
0
0
1
0
0
04H
CL = 6
15
SDRAM /CAS latencies supported, MSB
0
0
0
0
0
0
0
0
00H
—
16
SDRAM minimum /CAS latencies time
(tAA (min.))
-AE
0
1
1
0
1
0
0
1
69H
13.125ns
0
1
1
1
1
0
0
0
78H
15ns
-8C
-8C
17
SDRAM write recovery time (tWR)
0
1
1
1
1
0
0
0
78H
15ns
18
SDRAM minimum /RAS to /CAS delay
(tRCD)
-AE
0
1
1
0
1
0
0
1
69H
13.125ns
0
1
1
1
1
0
0
0
78H
15ns
19
SDRAM minimum row active to row active
delay (tRRD)
0
-AE
0
1
1
1
1
0
0
3CH
7.5ns
0
1
0
1
0
0
0
0
50H
10ns
20
SDRAM minimum row precharge time
(tRP)
-AE
0
1
1
0
1
0
0
1
69H
13.125ns
0
1
1
1
1
0
0
0
78H
15ns
0
0
0
1
0
0
0
1
11H
0
1
0
1
1
0
0
2CH
37.5ns
0
0
1
0
1
0
1
95H
50.625ns
1
0
1
0
0
1
0
0
A4H
52.5ns
0
1
1
1
0
0
0
0
70H
110ns
-8C
-8C
-8C
21
22
23
SDRAM upper nibbles for tRAS and tRC
SDRAM minimum active to precharge time
0
(tRAS), LSB
SDRAM minimum active to active /autorefresh time (tRC), LSB
1
-AE
-8C
24
SDRAM minimum refresh recovery time
delay (tRFC), LSB
Data Sheet E1412E20 (Ver. 2.0)
6
EBJ42HE8BAFA
Byte No. Function described
Bit7 Bit6
Bit5
Hex
Bit4 Bit3 Bit2 Bit1 Bit0 value
Comments
SDRAM minimum refresh recovery time
delay (tRFC), MSB
SDRAM minimum internal write to read
command delay (tWTR)
SDRAM minimum internal read to
precharge command delay (tRTP)
0
0
0
0
0
0
1
1
03H
110ns
0
0
1
1
1
1
0
0
3CH
7.5ns
0
0
1
1
1
1
0
0
3CH
7.5ns
28
Upper nibble for tFAW
0
0
0
0
0
0
0
1
01H
37.5ns
29
Minimum four activate window delay time
(tFAW)
-AE
0
0
1
0
1
1
0
0
2CH
37.5ns
0
1
0
0
0
0
0
0
40H
40ns
30
SDRAM output drivers supported
1
0
0
0
0
0
1
1
83H
DLL-off, RZQ/6, 7
31
SDRAM refresh options
1
0
0
0
0
0
0
1
81H
PASR/2X refresh rate
at +85°C to +95°C
32
Module thermal sensor
1
0
0
0
0
0
0
0
80H
Incorporated
33
SDRAM device type
0
0
0
0
0
0
0
0
00H
Standard
25
26
27
-8C
34 to 59 Reserved
0
0
0
0
0
0
0
0
00H
—
60
Module nominal height
0
0
0
1
0
0
0
0
10H
30 < height ≤ 31mm
61
Module maximum thickness
0
0
1
1
0
0
1
1
33H
62
Reference raw card used
0
0
0
0
0
1
1
1
07H
Raw card H
63
DIMM module attributes
0
0
0
0
1
0
0
1
09H
2row/1register
64
Heat spreader solution
1
0
0
0
0
0
0
0
80H
Incorporated
65
Register vender ID (LSB)
(Inphi)
0
0
0
0
0
1
0
0
04H
Naming bank = 5
1
0
0
0
0
0
0
0
80H
Naming bank = 1
66
Register vender ID (MSB)
(Inphi)
1
0
1
1
0
0
1
1
B3H
Actual ID
1
0
0
1
0
1
1
1
97H
67
Register revision
(Inphi)
0
0
0
0
0
0
1
1
03H
0
0
0
1
1
1
0
1
1DH
Rev.3.1
68
Register type
0
0
0
0
0
0
0
0
00H
SSTE32882
69
Register control word function (RC0, 1)
0
0
0
0
0
0
0
0
00H
Default
70
Register control word function (RC2, 3)
0
1
0
1
0
0
0
0
50H
Default
71
Register control word function (RC4, 5)
0
1
0
1
0
1
0
1
55H
Default
72
Register control word function (RC6, 7)
0
0
0
0
0
0
0
0
00H
Default
73
Register control word function (RC8, 9)
0
0
0
0
0
0
0
0
00H
Default
74
Register control word function (RC10, 11) 0
0
0
0
0
0
0
0
00H
Default
75
Register control word function (RC12, 13) 0
0
0
0
0
0
0
0
00H
Default
76
Register control word function (RC14, 15) 0
0
0
0
0
0
0
0
00H
Default
77 to
116
Module specific section
0
0
0
0
0
0
0
00H
—
(TI)
(TI)
(TI)
0
Data Sheet E1412E20 (Ver. 2.0)
7
Rev.4
EBJ42HE8BAFA
Byte No. Function described
117
118
Module ID: manufacturer’s JEDEC ID
code, LSB
Module ID: manufacturer’s JEDEC ID
code, MSB
Bit7 Bit6
Bit5
Hex
Bit4 Bit3 Bit2 Bit1 Bit0 value
Comments
0
0
0
0
0
0
1
0
02H
Elpida Memory
1
1
1
1
1
1
1
0
FEH
Elpida Memory
119
Module ID: manufacturing location
×
×
×
×
×
×
×
×
××
120
Module ID: manufacturing date
×
×
×
×
×
×
×
×
××
Year code (BCD)
121
Module ID: manufacturing date
×
×
×
×
×
×
×
×
××
Week code (BCD)
122 to
125
Module ID: module serial number
×
×
×
×
×
×
×
×
××
126
Cyclical redundancy code (CRC)
-AE (Inphi)
1
0
0
1
0
0
1
0
92H
0
0
0
0
1
1
0
1
0DH
-8C (Inphi)
0
0
0
0
1
0
1
0
0AH
(TI)
1
0
0
1
0
1
0
1
95H
0
0
0
1
0
0
1
1
13H
(TI)
127
Cyclical redundancy code (CRC)
-AE (Inphi)
(TI)
-8C (Inphi)
(TI)
0
1
1
0
1
1
1
0
6EH
0
1
0
0
1
0
1
0
4AH
0
0
1
1
0
1
1
1
37H
128
Module part number
0
1
0
0
0
1
0
1
45H
E
129
Module part number
0
1
0
0
0
0
1
0
42H
B
130
Module part number
0
1
0
0
1
0
1
0
4AH
J
131
Module part number
0
0
1
1
0
1
0
0
34H
4
132
Module part number
0
0
1
1
0
0
1
0
32H
2
133
Module part number
0
1
0
0
1
0
0
0
48H
H
134
Module part number
0
1
0
0
0
1
0
1
45H
E
135
Module part number
0
0
1
1
1
0
0
0
38H
8
136
Module part number
0
1
0
0
0
0
1
0
42H
B
137
Module part number
0
1
0
0
0
0
0
1
41H
A
138
Module part number
0
1
0
0
0
1
1
0
46H
F
139
Module part number
0
1
0
0
0
0
0
1
41H
A
140
Module part number
0
0
1
0
1
1
0
1
2DH
—
141
Module part number
-AE
0
1
0
0
0
0
0
1
41H
A
0
0
1
1
1
0
0
0
38H
8
142
Module part number
-AE
0
1
0
0
0
1
0
1
45H
E
0
1
0
0
0
0
1
1
43H
C
143
Module part number
0
0
1
0
1
1
0
1
2DH
—
144
Module part number
0
1
0
0
0
1
0
1
45H
E
-8C
-8C
Data Sheet E1412E20 (Ver. 2.0)
8
EBJ42HE8BAFA
Byte No. Function described
Bit7 Bit6
Bit5
Hex
Bit4 Bit3 Bit2 Bit1 Bit0 value
Comments
145
0
1
0
(Space)
Module part number
0
0
0
0
0
20H
146
Module revision code
0
0
1
1
0
0
0
0
30H
Initial
147
Module revision code
0
0
1
0
0
0
0
0
20H
(Space)
0
0
0
0
0
0
1
0
02H
Elpida Memory
1
1
1
1
1
1
1
0
FEH
Elpida Memory
0
0
0
0
0
0
0
0
00H
148
149
150 to
175
176 to
255
SDRAM manufacturer’s JEDEC ID code,
LSB
SDRAM manufacturer’s JEDEC ID code,
MSB
Manufacturer's specific data
Open for customer use
Data Sheet E1412E20 (Ver. 2.0)
9
EBJ42HE8BAFA
3
PCK1_A
/PCK1_A
RCKE1_A
VDD
/RCS3
/RCS2
PCK1_A
/PCK1_A
RCKE0_A
RODT1_A
PCK0_A
/PCK0_A
RCKE1_A
VDD
Data Sheet E1412E20 (Ver. 2.0)
10
/CS
Command
CK
/CK
CKE
ODT
Address BA
ODT
Address BA
/CS
Command
CK
/CK
CKE
DQS
/DQS
D28
/CS
Command
CK
/CK
CKE
ODT
Rs5
ODT
Address BA
/TDQS
DQ0
to DQ7
ZQ
TDQS
D27
ZQ
VTT
Address BA
TDQS
VTT
Address BA
/DQS
D29
/CS
Command
CK
/CK
CKE
ODT
DQS
ODT
Address BA
/CS
Command
CK
/CK
CKE
Rs5
Rs5
Rs5
/TDQS
DQ0
to DQ7
ZQ
/TDQS
DQ0
to DQ7
VTT
Rs4
Block Diagram (1)
TDQS
ODT
Address BA
/CS
Command
CK
/CK
CKE
VTT
D30
Rs3
VTT
/DQS
Rs3
VTT
/TDQS
DQ0
to DQ7
ZQ
DQS
D18
ZQ
D35
TDQS
ODT
Address BA
/CS
Command
CK
/CK
CKE
Rs5
TDQS
Rs4
ODT
Address BA
/CS
Command
CK
/CK
CKE
Rs5
ODT
Address BA
/DQS
/TDQS
DQ0
to DQ7
ZQ
/DQS
D19
ZQ
DQS
D9
ODT
Address BA
/CS
Command
CK
/CK
CKE
/CS
Command
CK
/CK
CKE
ODT
Address BA
TDQS
Rs5
Rs3
Rs3
Rs3
Rs3
Rs3
/DQS
TDQS
DQ0
to DQ7
VTT
VTT
D10
ZQ
DQS
D0
/TDQS
DQ0
to DQ7
/TDQS
DQ0
to DQ7
ZQ
DQS
Rs5
/TDQS
8 RS1 DQ0
DQ0 to DQ7
to DQ7
ZQ
TDQS
Rs3
Rs5
TDQS
/DQS
Rs3
RS1
/DQS
Rs5
/TDQS9
RS1
DQS
DQS
TDQS
D20
Rs3
DM0/TDQS9
RS1
ZQ
/TDQS
DQ0
to DQ7
ZQ
/CS
Command
CK
/CK
CKE
/DQS0
RS1
D1
TDQS
D11
TDQS
/TDQS
DQ0
to DQ7
/CS
Command
CK
/CK
CKE
DQS0
/DQS
/DQS
/DQS
D21
Rs3
/TDQS
RS1
DQ0
DQ8 to DQ15 8
to DQ7
DQS
DQS
Rs5
Rs5
TDQS
/TDQS
DQ0
to DQ7
ZQ
/TDQS
DQ0
to DQ7
ZQ
Rs3
/DQS
TDQS
ODT
Address BA
RS1
Rs5
/TDQS10
RS1
DQS
/DQS
ODT
Address BA
DM1/TDQS10
RS1
/CS
Command
CK
/CK
CKE
/DQS1
RS1
DQS
D2
Rs5
DQS1
ZQ
Rs5
/TDQS
8 RS1 DQ0
DQ16 to DQ23
to DQ7
ZQ
/TDQS11
/RCS1
Rs5
TDQS
D12
DQS
D26
TDQS
Rs5
RS1
/DQS
/DQS
ODT
Address BA
RS1
DQS
ODT
Address BA
DM2/TDQS11
RS1
/CS
Command
CK
/CK
CKE
/DQS2
RS1
/TDQS
DQ0
to DQ7
D3
Rs5
DQS2
TDQS
DQS
ODT
Address BA
/TDQS
8 RS1 DQ0
DQ24 to DQ31
to DQ7
ZQ
/DQS
ODT
Address BA
TDQS
DQS
D17
/CS
Command
CK
/CK
CKE
RS1
/DQS
/TDQS
DQ0
to DQ7
ZQ
Rs3
/TDQS12
RS1
DQS
/TDQS
DQ0
to DQ7
ZQ
/CS
Command
CK
/CK
CKE
DM3/TDQS12
RS1
/DQS
TDQS
/CS
Command
CK
/CK
CKE
/DQS3
RS1
D8
DQ0
to DQ7
ZQ
DQS
TDQS
/CS
Command
CK
/CK
CKE
DQS3
/DQS
Rs3
RS1
/TDQS
DQS
Rs5
8
Rs5
CB0 to CB7
TDQS
ODT
Address BA
RS1
/TDQS17
/DQS
ODT
Address BA
RS1
DM8/TDQS17
DQS
/CS
Command
CK
/CK
CKE
RS1
/DQS8
17
/CS
Command
CK
/CK
CKE
RS1
DQS8
R[Address, BA]_A
RCKE0_A
RODT0_A
/RCS0
Rcommand_A
PCK0_A
/PCK0_A
Block Diagram
3
/RCS3
PCK1_B
/PCK1_B
RCKE1_B
VDD
PCK1_B
/PCK1_B
RCKE0_B
RODT1_B
/RCS2
PCK0_B
/PCK0_B
RCKE0_B
VDD
Data Sheet E1412E20 (Ver. 2.0)
11
/DQS
TDQS
D34
Rs3
VTT
DQ0
to DQ7
ZQ
VTT
VTT
ODT
Address BA
Address BA
DQS
D33
/CS
Command
CK
/CK
CKE
ODT
Rs5
ODT
Address BA
/TDQS
DQ0
to DQ7
ZQ
ODT
Address BA
/CS
Command
CK
/CK
CKE
TDQS
Rs5
VTT
Rs4
Block Diagram (2)
D32
/TDQS
Rs3
VTT
/CS
Command
CK
/CK
CKE
Rs5
/DQS
D25
DQ0
to DQ7
ZQ
Rs3
VTT
Rs4
/TDQS
DQ0
to DQ7
ZQ
DQS
/TDQS
D16
D31
TDQS
D24
TDQS
/CS
Command
CK
/CK
CKE
ODT
Address BA
ODT
Address BA
ODT
Address BA
/DQS
Rs5
Rs5
/DQS
/TDQS
DQ0
to DQ7
ZQ
DQS
ODT
Address BA
/CS
Command
CK
/CK
CKE
/TDQS
DQ0
to DQ7
ZQ
DQS
TDQS
Rs3
VTT
VTT
DQ0
to DQ7
ZQ
/CS
Command
CK
/CK
CKE
Rs5
ODT
Address BA
D15
TDQS
D7
/CS
Command
CK
/CK
CKE
/CS
Command
CK
/CK
CKE
ODT
Address BA
TDQS
/TDQS
DQ0
to DQ7
ZQ
Rs3
/DQS
Rs3
ODT
Address BA
/DQS
Rs5
RS1
/TDQS
DQ0
to DQ7
ZQ
DQS
/TDQS
Rs3
8
Rs5
DQ56 to DQ63
TDQS
Rs3
RS1
/TDQS16
/DQS
Rs3
RS1
DM7/TDQS16
DQS
/CS
Command
CK
/CK
CKE
RS1
/DQS7
/RCS1
D6
Rs3
RS1
DQS7
TDQS
DQS
/DQS
D23
/CS
Command
CK
/CK
CKE
/TDQS
8 RS1 DQ0
to DQ7
ZQ
/DQS
/TDQS
DQ0
to DQ7
ZQ
Rs3
RS1
Rs5
DQ48 to DQ55
TDQS
DQS
Rs5
/TDQS15
/DQS
D14
DQS
D22
TDQS
Rs3
RS1
DM6/TDQS15
DQS
/TDQS
DQ0
to DQ7
ZQ
/DQS
Rs5
/DQS6
TDQS
DQS
Rs5
RS1
ZQ
D13
ODT
Address BA
RS1
DQS6
/DQS
D5
DQ0
to DQ7
/TDQS
DQ0
to DQ7
ZQ
ODT
Address BA
RS1
/TDQS
/TDQS
DQ0
to DQ7
ZQ
Rs3
8
Rs5
DQ40 to DQ47
TDQS
/DQS
TDQS
DQS
Rs5
RS1
/TDQS14
/DQS
ODT
Address BA
RS1
DM5/TDQS14
DQS
ODT
Address BA
/DQS5
/CS
Command
CK
/CK
CKE
RS1
DQS
TDQS
/CS
Command
CK
/CK
CKE
D4
/CS
Command
CK
/CK
CKE
RS1
DQS5
/DQS
/CS
Command
CK
/CK
CKE
/TDQS
8 RS1
DQ0
to DQ7
ZQ
Rs5
DQ32 to DQ39
RS1
TDQS
DQS
Rs5
/TDQS13
/DQS
/CS
Command
CK
/CK
CKE
RS1
DM4/TDQS13
DQS
Rs3
/DQS4
ODT
Address BA
RS1
17
/CS
Command
CK
/CK
CKE
RS1
DQS4
R[Address, BA]_B
RCKE0_B
RODT0_B
/RCS0
Rcommand_B
PCK1_B
/PCK1_B
EBJ42HE8BAFA
EBJ42HE8BAFA
/CS0
/CS1
/CS2
/CS3
BA
Address
Rs2
/RCS0 -> /CS: SDRAMs D0 to D8
Rs2
1:2
/RCS1 -> /CS: SDRAMs D9 to D17
Rs2
/RCS2 -> /CS: SDRAMs D18 to D26
Rs2
/RCS3 -> /CS: SDRAMs D27 to D35
RBA_A -> BA0 to BA2: SDRAMs D0 to D3, D8 to D12, D17 to D21, D26 to D30, D35
RBA_B -> BA0 to BA2: SDRAMs D4 to D7, D13 to D16, D22 to D25, D31 to D34
Rs2
Rs2
RAddress_A -> A0 to A13: SDRAMs D0 to D3, D8 to D12, D17 to D21, D26 to D30, D35
RAddress_B -> A0 to A13: SDRAMs D4 to D7, D13 to D16, D22 to D25, D31 to D34
Rcommand_A -> /RAS, /CAS, /WE: SDRAMs D0 to D3, D8 to D12, D17 to D21, D26 to D30, D35
Rcommand_B -> /RAS, /CAS, /WE: SDRAMs D4 to D7, D13 to D16, D22 to D25, D31 to D34
Rs2
Command
CKE0
CKE1
ODT0
ODT1
Rs2
RCKE0_A -> CKE: SDRAMs D0 to D3, D8, D18 to D21, D26
RCKE0_B -> CKE: SDRAMs D4 to D7, D22 to D25
R
E
G
I
S
T
E
R
Rs2
Rs2
Rs2
RODT0_A -> ODT: SDRAMs D0 to D3, D8
RODT0_B-> ODT: SDRAMs D4 to D7
/
RODT1_A -> ODT: SDRAMs D18 to D21, D26
RODT1_B -> ODT: SDRAMs D22 to D25
P
L
L
PCK0_A -> CK: SDRAMs D0 to D3, D8 to D12, D17
PCK0_B -> CK: SDRAMs D4 to D7, D13 to D16
PCK1_A -> CK: SDRAMs D18 to D21, D26 to D30, D35
PCK1_B -> CK: SDRAMs D22 to D25, D31 to D34
Rs4
CK0
RCKE1_A -> CKE: SDRAMs D9 to D12, D17, D27 to D30, D35
RCKE1_B -> CKE: SDRAMs D13 to D16, D31 to D34
/PCK0_A -> CK: SDRAMs D0 to D3, D8 to D12, D17
/PCK0_B -> CK: SDRAMs D4 to D7, D13 to D16
/CK0
Par_In
Rs2
/RESET
Note:
1. DQ wiring may be changed within a byte.
/PCK1_A -> CK: SDRAMs D18 to D21, D26 to D30, D35
/PCK1_B -> CK: SDRAMs D22 to D25, D31 to D34
/Err_Out
/RESET
* D0 to D35: 1G bits DDR3 SDRAM
Address, BA: A0 to A15, BA0 to BA2
Command: /RAS, /CAS, /WE
U1: 256 bytes EEPROM
Rs1: 15Ω
Rs2: 22Ω
Rs3: 47Ω
Rs4: 120Ω
Rs5: 240Ω
Register: SSTE32882
/RESET: SDRAMs D0 to D35
RS 4
CK1
/CK1
VTT
VDDSPD
VREFCA
VREFDQ
VDD
VSS
Terminated at near
card edge
SPD
SDRAMs (D0 to D35)
SDRAMs (D0 to D35)
SDRAMs (D0 to D35)
SCL
SCL
SA0
A0
SDRAMs (D0 to D35), SPD
SA1
SA2
A1
A2 /EVENT
Serial PD
SDA
SDA
U1
D10
D11
D12
D17
D13
D14
D15
D16
VTT
D27
D27
D28
D29
D30
D35
D31
D32
D33
D34
VTT
VTT
D18
D19
D20
D21
D26
D22
D23
D24
D25
VTT
D0
D1
D2
D3
D8
D4
D5
D6
D7
VTT
Register
Address, command and control line
Block Diagram (3)
Data Sheet E1412E20 (Ver. 2.0)
12
VTT
VTT
D9
VTT
/EVENT
EBJ42HE8BAFA
Electrical Specifications
• All voltages are referenced to VSS (GND).
Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
Notes
Power supply voltage
VDD
−0.4 to +1.975
V
1, 3, 4
Input voltage
VIN
−0.4 to +1.975
V
1, 4
Output voltage
VOUT
−0.4 to +1.975
V
1, 4
Reference voltage
VREFCA
−0.4 to 0.6 × VDD
V
3, 4
Reference voltage for DQ
VREFDQ
−0.4 to 0.6 × VDDQ
V
3, 4
1, 2, 4
Storage temperature
Tstg
−55 to +100
°C
Power dissipation
PD
9
W
Short circuit output current
IOUT
50
mA
1, 4
Notes: 1. Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to
the device. This is a stress rating only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of this specification is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect reliability.
2. Storage temperature is the case surface temperature on the center/top side of the DRAM.
3. VDD and VDDQ must be within 300mV of each other at all times; and VREF must be not greater than
0.6 × VDDQ, When VDD and VDDQ are less than 500mV; VREF may be equal to or less than 300mV.
4. DDR3 SDRAM component specification.
Caution
Exposing the device to stress above those listed in Absolute Maximum Ratings could cause
permanent damage. The device is not meant to be operated under conditions outside the limits
described in the operational section of this specification Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
Operating Temperature Condition
Parameter
Symbol
Rating
Unit
Notes
Operating case temperature
TC
0 to +95
°C
1, 2, 3
Notes: 1. Operating temperature is the case surface temperature on the center/top side of the DRAM.
2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be
supported. During operation, the DRAM case temperature must be maintained between 0°C to +85°C
under all operating conditions.
3. Some applications require operation of the DRAM in the Extended Temperature Range between +85°C
and +95°C case temperature. Full specifications are guaranteed in this range, but the following additional
conditions apply:
a)
Refresh commands must be doubled in frequency, therefore reducing the refresh interval tREFI to
3.9µs. (This double refresh requirement may not apply for some devices.)
b)
If Self-refresh operation is required in the Extended Temperature Range, then it is mandatory to
either use the Manual Self-Refresh mode with Extended Temperature Range capability (MR2 bit
[A6, A7] = [0, 1]) or enable the optional Auto Self-Refresh mode (MR2 bit [A6, A7] = [1, 0]).
Data Sheet E1412E20 (Ver. 2.0)
13
EBJ42HE8BAFA
Recommended DC Operating Conditions (TC = 0°C to +85°C)
Parameter
Symbol
min.
typ.
max.
Unit
Notes
Supply voltage
VDD, VDDQ
1.425
1.5
1.575
V
1, 2, 3
VSS
0
0
0
V
1
3.6
VDDSPD
3.0
3.3
Input reference voltage
VREFCA (DC)
0.49 × VDDQ
0.50 × VDDQ 0.51 × VDDQ
V
1, 4, 5
Input reference voltage for DQ
VREFDQ (DC)
0.49 × VDDQ
0.50 × VDDQ 0.51 × VDDQ
V
1, 4, 5
Termination voltage
VTT
VDDQ/2 – TBD
TBD
V
Notes: 1.
2.
3.
4.
VDDQ/2 + TBD
V
DDR3 SDRAM component specification.
Under all conditions VDDQ must be less than or equal to VDD.
VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together.
The AC peak noise on VREF may not allow VREF to deviate from VREF(DC) by more than ±1% VDD (for
reference: approx ±15 mV).
5. For reference: approx. VDD/2 ±15 mV.
Data Sheet E1412E20 (Ver. 2.0)
14
EBJ42HE8BAFA
DC Characteristics 1 (TC = 0°C to +85°C, VDD = 1.5V ± 0.075V, VSS = 0V)
Parameter
Operating current
(ACT-PRE)
Operating current
(ACT-READ-PRE)
Symbol
IDD0
IDD1
IDD2PF
Precharge power-down standby current
IDD2PS
Precharge quiet standby current
IDD2Q
Precharge standby current
IDD2N
Active power-down current
(Always fast exit)
IDD3P
Active standby current
IDD3N
Operating current
(Burst read operating)
Operating current
(Burst write operating)
IDD4R
IDD4W
Burst refresh current
IDD5B
Self-refresh current
normal temperature range
IDD6
All bank interleave read current
IDD7R
Data rate (Mbps)
max.
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
1066
800
2260
2040
2470
2260
1520
1400
1320
1230
2020
1820
2020
1820
1470
1360
2050
1820
2970
2320
3140
2510
3910
3740
1066
800
Data Sheet E1412E20 (Ver. 2.0)
15
Unit
Notes
mA
mA
mA
Fast PD Exit
mA
Slow PD Exit
mA
mA
mA
mA
mA
mA
mA
1300
mA
3820
3490
mA
EBJ42HE8BAFA
AC Timing for IDD Test Conditions
For purposes of IDD testing, the following parameters are to be utilized.
Parameter
DDR3-1066
DDR3-800
7-7-7
6-6-6
Unit
CL (IDD)
7
6
tCK
tCK min.(IDD)
1.875
2.5
ns
tRCD min. (IDD)
13.13
15
ns
tRC min. (IDD)
50.63
52.5
ns
tRAS min.(IDD)
37.5
37.5
ns
tRP min. (IDD)
13.13
15
ns
tFAW (IDD)
37.5
40
ns
tRRD (IDD)
7.5
10
ns
tRFC (IDD)
110
110
ns
DC Characteristics 2 (TC = 0°C to +85°C, VDD, VDDQ = 1.5V ± 0.075V)
(DDR3 SDRAM Component Specification)
Parameter
Symbol
Value
Input leakage current
ILI
2
µA
VDD ≥ VIN ≥ VSS
Output leakage current
ILO
5
µA
DDQ ≥ VOUT ≥ VSS
Data Sheet E1412E20 (Ver. 2.0)
16
Unit
Notes
EBJ42HE8BAFA
Pin Functions
CK, /CK (input pin)
CK and /CK are differential clock inputs. All address and control input signals are sampled on the crossing of the
positive edge of CK and negative edge of /CK. Output (read) data is referenced to the crossings of CK and /CK
(both directions of crossing).
/CS (input pin)
All commands are masked when /CS is registered high. /CS provides for external rank selection on systems with
multiple ranks. /CS is considered part of the command code.
/RAS, /CAS, and /WE (input pins)
/RAS, /CAS and /WE (along with /CS) define the command being entered.
A0 to A15 (input pins)
Provided the row address for active commands and the column address for read/write commands to select one
location out of the memory array in the respective bank. (A10(AP) and A12(/BC) have additional functions, see
below) The address inputs also provide the op-code during mode register set commands.
[Address Pins Table]
Address (A0 to A13)
Row address (RA)
Column address (CA)
AX0 to AX13
AY0 to AY9
Notes
A10(AP) (input pin)
A10 is sampled during read/write commands to determine whether auto-precharge should be performed to the
accessed bank after the read/write operation. (high: auto-precharge; low: no auto-precharge)
A10 is sampled during a precharge command to determine whether the precharge applies to one bank (A10 = low)
or all banks (A10 = high). If only one bank is to be precharged, the bank is selected by bank addresses (BA).
A12 (/BC) (input pin)
A12 is sampled during read and write commands to determine if burst chop (on-the-fly) will be performed.
(A12 = high: no burst chop, A12 = low: burst chopped.)
BA0 to BA2 (input pins)
BA0, BA1 and BA2 define to which bank an active, read, write or precharge command is being applied. BA0 and
BA1 also determine if a mode register is to be accessed during a MRS cycle.
[Bank Select Signal Table]
BA0
BA1
BA2
Bank 0
L
L
L
Bank 1
H
L
L
Bank 2
L
H
L
Bank 3
H
H
L
Bank 4
L
L
H
Bank 5
H
L
H
Bank 6
L
H
H
Bank 7
H
H
H
Remark: H: VIH. L: VIL.
Data Sheet E1412E20 (Ver. 2.0)
17
EBJ42HE8BAFA
CKE (input pin)
CKE high activates, and CKE low deactivates, internal clock signals and device input buffers and output drivers.
Taking CKE low provides precharge power-down and self-refresh operation (all banks idle), or active power-down
(row active in any bank). CKE is asynchronous for self-refresh exit. After VREF has become stable during the
power-on and initialization sequence, it must be maintained for proper operation of the CKE receiver. For proper
self-refresh entry and exit, VREF must be maintained to this input. CKE must be maintained high throughout read
and write accesses. Input buffers, excluding CK, /CK, ODT and CKE are disabled during power-down. Input buffers,
excluding CKE, are disabled during self-refresh.
DQ and CB (input and output pins)
Bi-directional data bus.
DQS and /DQS (input and output pin)
Output with read data, input with write data. Edge-aligned with read data, centered in write data.
The data strobe DQS is paired with differential signals /DQS to provide differential pair signaling to the system during
READs and WRITEs.
ODT (input pins)
ODT (registered high) enables termination resistance internal to the DDR3 SDRAM. When enabled, ODT is only
applied to each DQ, DQS, /DQS, DM. The ODT pin will be ignored if the mode register (MR1) is programmed to
disable ODT.
DM (input pins)
DM is an input mask signal for write data. Input data is masked when DM is sampled high coincident with that input
data during a write access. DM is sampled on both edges of DQS. For ×8 configuration, the function of DM or
TDQS, /TDQS is enabled by mode register A11 setting in MR1.
TDQS, /TDQS (output pins)
TDQS and /TDQS is applicable for ×8 configuration only. When enabled via mode register A11 = 1 in MR1, DRAM
will enable the same termination resistance function on TDQS, /TDQS that is applied to DQS, /DQS. When disabled
via mode register A11 = 0 in MR1, DM/TDQS will provide the data mask function and /TDQS is not used. ×4/×16
configuration must be disabled the TDQS function via mode register A11 = 0 in MR1.
VDD (power supply pins)
1.5V is applied. (VDD is for the internal circuit.)
VDDSPD (power supply pin)
3.3V is applied (For serial EEPROM).
VSS (power supply pin)
Ground is connected.
VTT (power supply pin)
Termination supply.
VREFDQ (power supply)
Reference voltage for DQ.
VREFCA (power supply)
Reference voltage for CA.
SCL (input pin)
Clock input for serial PD.
Data Sheet E1412E20 (Ver. 2.0)
18
EBJ42HE8BAFA
SDA (input and output pins)
Data input/output for serial PD.
SA (input pin)
Serial address input.
/RESET (input pin)
/RESET is negative active signal (active low) and is referred to GND.
Par_In (input pin)
Parity bit for the Address and Control bus.
/Err_Out (output pin)
Parity error found on the Address and Control bus.
/Event (output pin)
Temperature alert output.
Detailed Operation Part, Electrical Characteristics and Timing Waveforms
Refer to the EDJ1104BASE, EDJ1108BASE, EDJ1116BASE datasheet (E1128E). DIMM /CAS latency =
component CL + 1 for registered type.
Data Sheet E1412E20 (Ver. 2.0)
19
EBJ42HE8BAFA
Physical Outline
Unit: mm
Front side
8.50 max
(DATUM -A-)
4.00 min
(Front)
1
120
B
A
47.00
1.27 ± 0.10
71.00
133.35
(Back)
30.50 max
240
17.30
121
9.50
Back side
C
± ± ± ± ± ECA-TS2-0245-02
Data Sheet E1412E20 (Ver. 2.0)
20
EBJ42HE8BAFA
CAUTION FOR HANDLING MEMORY MODULES
When handling or inserting memory modules, be sure not to touch any components on the modules, such as
the memory ICs, chip capacitors and chip resistors. It is necessary to avoid undue mechanical stress on
these components to prevent damaging them.
In particular, do not push module cover or drop the modules in order to protect from mechanical defects,
which would be electrical defects.
When re-packing memory modules, be sure the modules are not touching each other.
Modules in contact with other modules may cause excessive mechanical stress, which may damage the
modules.
MDE0202
NOTES FOR CMOS DEVICES
1
PRECAUTION AGAINST ESD FOR MOS DEVICES
Exposing the MOS devices to a strong electric field can cause destruction of the gate
oxide and ultimately degrade the MOS devices operation. Steps must be taken to stop
generation of static electricity as much as possible, and quickly dissipate it, when once
it has occurred. Environmental control must be adequate. When it is dry, humidifier
should be used. It is recommended to avoid using insulators that easily build static
electricity. MOS devices must be stored and transported in an anti-static container,
static shielding bag or conductive material. All test and measurement tools including
work bench and floor should be grounded. The operator should be grounded using
wrist strap. MOS devices must not be touched with bare hands. Similar precautions
need to be taken for PW boards with semiconductor MOS devices on it.
2
HANDLING OF UNUSED INPUT PINS FOR CMOS DEVICES
No connection for CMOS devices input pins can be a cause of malfunction. If no
connection is provided to the input pins, it is possible that an internal input level may be
generated due to noise, etc., hence causing malfunction. CMOS devices behave
differently than Bipolar or NMOS devices. Input levels of CMOS devices must be fixed
high or low by using a pull-up or pull-down circuitry. Each unused pin should be connected
to VDD or GND with a resistor, if it is considered to have a possibility of being an output
pin. The unused pins must be handled in accordance with the related specifications.
3
STATUS BEFORE INITIALIZATION OF MOS DEVICES
Power-on does not necessarily define initial status of MOS devices. Production process
of MOS does not define the initial operation status of the device. Immediately after the
power source is turned ON, the MOS devices with reset function have not yet been
initialized. Hence, power-on does not guarantee output pin levels, I/O settings or
contents of registers. MOS devices are not initialized until the reset signal is received.
Reset operation must be executed immediately after power-on for MOS devices having
reset function.
CME0107
Data Sheet E1412E20 (Ver. 2.0)
21
EBJ42HE8BAFA
The information in this document is subject to change without notice. Before using this document, confirm that this is the latest version.
No part of this document may be copied or reproduced in any form or by any means without the prior
written consent of Elpida Memory, Inc.
Elpida Memory, Inc. does not assume any liability for infringement of any intellectual property rights
(including but not limited to patents, copyrights, and circuit layout licenses) of Elpida Memory, Inc. or
third parties by or arising from the use of the products or information listed in this document. No license,
express, implied or otherwise, is granted under any patents, copyrights or other intellectual property
rights of Elpida Memory, Inc. or others.
Descriptions of circuits, software and other related information in this document are provided for
illustrative purposes in semiconductor product operation and application examples. The incorporation of
these circuits, software and information in the design of the customer's equipment shall be done under
the full responsibility of the customer. Elpida Memory, Inc. assumes no responsibility for any losses
incurred by customers or third parties arising from the use of these circuits, software and information.
[Product applications]
Be aware that this product is for use in typical electronic equipment for general-purpose applications.
Elpida Memory, Inc. makes every attempt to ensure that its products are of high quality and reliability.
However, users are instructed to contact Elpida Memory's sales office before using the product in
aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment,
medical equipment for life support, or other such application in which especially high quality and
reliability is demanded or where its failure or malfunction may directly threaten human life or cause risk
of bodily injury.
[Product usage]
Design your application so that the product is used within the ranges and conditions guaranteed by
Elpida Memory, Inc., including the maximum ratings, operating supply voltage range, heat radiation
characteristics, installation conditions and other related characteristics. Elpida Memory, Inc. bears no
responsibility for failure or damage when the product is used beyond the guaranteed ranges and
conditions. Even within the guaranteed ranges and conditions, consider normally foreseeable failure
rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so
that the equipment incorporating Elpida Memory, Inc. products does not cause bodily injury, fire or other
consequential damage due to the operation of the Elpida Memory, Inc. product.
[Usage environment]
Usage in environments with special characteristics as listed below was not considered in the design.
Accordingly, our company assumes no responsibility for loss of a customer or a third party when used in
environments with the special characteristics listed below.
Example:
1) Usage in liquids, including water, oils, chemicals and organic solvents.
2) Usage in exposure to direct sunlight or the outdoors, or in dusty places.
3) Usage involving exposure to significant amounts of corrosive gas, including sea air, CL 2 , H 2 S, NH 3 ,
SO 2 , and NO x .
4) Usage in environments with static electricity, or strong electromagnetic waves or radiation.
5) Usage in places where dew forms.
6) Usage in environments with mechanical vibration, impact, or stress.
7) Usage near heating elements, igniters, or flammable items.
If you export the products or technology described in this document that are controlled by the Foreign
Exchange and Foreign Trade Law of Japan, you must follow the necessary procedures in accordance
with the relevant laws and regulations of Japan. Also, if you export products/technology controlled by
U.S. export control regulations, or another country's export control laws or regulations, you must follow
the necessary procedures in accordance with such laws or regulations.
If these products/technology are sold, leased, or transferred to a third party, or a third party is granted
license to use these products, that third party must be made aware that they are responsible for
compliance with the relevant laws and regulations.
M01E0706
Data Sheet E1412E20 (Ver. 2.0)
22