CXA10
Single output
Total Power:
10W
Input Voltage: 18 - 75VDC
# of Outputs: Single
Special Features
• 4:1 input voltage range
• Operating ambient
temperature of -40°C to
+70°C in still air
• High demonstrated reliability
with conservative
component deratings
• Complies with
ETS 300 019-1-3/2-3
• Complies with ETS 300 132-2
input voltage and current
requirements
• Fully compliant with
ETS 300 386-1
• Pin compatible with NFC10
and BXA10 series
• Basic insulation system
(input to output)
• 2 year warranty
Safety
UL/cUL CAN/CSA 22.2
No. 60950-00 : UL 60950-1
File No. E132002
VDE Certificate No.112607.
File No. 1040100-3336-0136
CB Report and Certificate to
IEC60950-1, #DE 1-30686
The CXA10 series comprising of five different models delivers
single and dual output voltages covering 3.3 V, 5 V, 12 V, ±5 V, ±12
V and ±15 V. The series has a wide 4:1 input voltage range of
18Vdc to 75 Vdc. The CXA10 has been designed as a competitive
open-frame alternative for the communications market. The
product is supplied in the industry standard footprint of 2.0 x 1.0 x
0.394 inches. Other product features include overvoltage
protection, short-circuit protection and remote ON/OFF.
All components are placed in a fully automated environment.
Planar magnetics are used in the design to improve the reliability
and reduce the profile of the dc-dc converter. The series has full
international safety approvals reducing system compliance costs,
and it has a basic insulation system from input to output making it
suitable for a wide variety of applications.
Embedded Power for
Business-Critical Continuity
Rev.12.04.07
cxa10
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage accuracy
±1.0%
Line regulation
(LL to HL)
Singles/dual positives
Dual negatives
Load regulation
(not incl. cross reg.)
Full load to
minimum load
Min. load
All outputs
Ripple and noise
20 MHz bandwidth
3.3 V and 5.0 V
All others
All models
±0.1%
±0.2%
±0.15%
10%
30 mV pk-pk
60 mV pk-pk
12 mV rms
Temperature coefficient
±0.01%/°C
Overvoltage protection
Clamp type
(See table and Notes 3, 4)
Short circuit protection
Short <20 mΩ
Hiccup
Transient response
Min. load to FL
±1.0%
Load cross regulation
Min. load to FL (See Note 1)
±5.0%
Continuous
auto. recovery
INPUT SPECIFICATIONS
Input voltage range
48 Vin nominal
18-75 Vdc
Input fuse
(See Note 10)
1.5 A HRC
Max. input rise
and fall time
48 V ETS300 132-2
UVLO turn ON voltage
UVLO turn OFF voltage
(See Note 5)
(See Note 5)
Remote ON/OFF
Logic compatibility
ON
OFF
5 V/ms
94%
86%
(See Note 7)
CMOS/TTL/Open Collector
Open circuit
<1 Vdc
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge (500 V)
Fast transients
Radiated immunity
Conducted immunity
EN55022 (See Note 6)
EN55022, external filter,
VDE0878, 48 V models
See Application Note 100
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3, 4
EN61000-4-4, level 3, 4
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level B
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and standards
(See Notes 7,8,9,10,11)
Material flammability
Weight
MTBF
(Representative model
48S05J @ 48 Vin)
See table
Input/output test voltage
1500 Vdc
Fixed
400 kHz
EN60950, UL1950
CSA C22.2 No. 950
UL94V-0
12 g (0.42 oz)
MIL-HDBK-217F
456,621 hours
Parts stress method
Ground Benign @ 25 °C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
-40 °C to +70 °C,
temperature
See curves
Non-operating
-55 °C to +105 °C
ETS 300 019-2-3
Classes T3.1 to T3.5
Air temperature
Low: IEC 68-2-1
-40 °C
High: IEC 68-2-2
+70 °C
Change: IEC 68-2-14
-40°C to +70 °C
Relative humidity
IEC 68-2-56
10% to 100% RH
IEC 68-2-30
Condensation
Vibration, Class 3M5
IEC68-2-6
2-9 Hz, 3 mm disp.
9-200 Hz 1 g
MIL-STD-202F
Method 204 cond. A
Shock, Class 3M5
IEC-68-2-29
Method 213B cond. A
MIL-STD-202F
Embedded Power for
Business-Critical Continuity
Rev.12.04.07
cxa10
3 of 4
Specifications Contd.
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OVERVOLTAGE
PROTECTION (3,4)
OUTPUT
CURRENT (MAX.) (9)
TYPICAL
EFFICIENCY
MODEL
NUMBER (7,12,13)
18-75 Vdc
3.3 V
3.9 V
2.4 A
78%
CXA10-48S3V3J
18-75 Vdc
5V
6.8 V
2A
81%
CXA10-48S05J
18-75 Vdc
12 V
16 V
0.83 A
83%
CXA10-48S12J
18-75 Vdc
±5 V
±6.8 V
1A
81%
CXA10-48D05J
18-75 Vdc
±12 V
±16 V
0.41 A
83%
CXA10-48D12J
18-75 Vdc
±15 V
±19 V
0.33 A
81%
CXA10-48D15J
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
Negative output voltage deviation when positive load is changed.
Guaranteed minimum output voltage range.
TVS spec: See Application Note 100 on our web site.
On dual output models, OVP protection is on negative outputs only.
With respect to minimum input voltage.
With one external ITW Paktron 4.7 μF film capacitor across the input.
For units with optional remote ON/OFF, please add the suffix ‘-S’ to the model
number, e.g. CXA10-48S05-SJ. Additional alphanumeric suffixes maybe
added to indicate minor modifications not affecting the safety approvals.
Unit provides basic insulation up to the 75 Vdc maximum input voltage.
Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for
the 3V3 model.
User must provide 1.5 A in line fuse in order to comply with safety approvals.
Maximum temperature on components Q100, CR101, CR102 not to exceed
120 °C. See Application Note 100 for details.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
0.400
(10.16)
0.100
(2.54)
0.400
(10.16)
0.020
(0.50)
Ø0.040 ±0.002
Dia. (Ø1.02 ±0.05)
3
4
5
0.800
(20.32)
±0.020 (0.5)
2.000
(50.80)
1
2
6
0.600
(15.24)
0.400
(10.16)
0.200
(5.08)
0.300
(7.62)
0.394
(10.00)
Max.
0.142 (3.60)
± 0.012 (0.3)
OPENFRAME
HEIGHT
± 0.012 (0.3)
0.536 (13.60)
1.000 (25.40)
± 0.020 (0.5)
ALL DIMENSIONS IN INCHES (mm)
Tolerance on all dimensions of ± 0.005 (0.127)
Unless otherwise specified
PIN CONNECTIONS
DERATING CURVE
(Output Power %)
100%
Output Power (%)
75%
PIN NUMBER
SINGLE OUTPUT
DUAL OUTPUT
1
+ Input
+ Input
2
– Input
- Input
6*
Remote ON/OFF
Remote ON/OFF
3
+ Output
+ Output
4
No Pin
Common
5
- Output
- Output
50%
25%
27.5%
0%
-40°C -30°C -20°C -10°C 0°C
10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C
90°C 100°C
AMBIENT TEMPERATURE (°C)
Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100
* Optional remote ON/OFF pin. Please add the suffix ‘-S’ to the model
number, e.g. CXA10-48S05-SJ (See Note 7).
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Embedded Power for
Business-Critical Continuity
Rev.12.04.07
cxa10
4 of 4
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.