ARTESYN CXA10

CXA10 Series
Single and dual output
DC/DC CONVERTERS
•
•
•
•
•
•
•
•
•
10W DC/DC Converters
1
4:1 input voltage range
Approved to EN60950, UL1950, CSA C22.2 No. 950
Operating ambient temperature of -40°C to +70°C in still air
High demonstrated reliability with conservative component deratings
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 input voltage and current requirements
Fully compliant with ETS 300 386-1
Pin compatible with NFC10 and BXA10 series
Basic insulation system (input to output)
The CXA10 series comprising of five different models delivers single and dual output
voltages covering 3.3V, 5V, 12V, ±5V, ±12 and ±15V. The series has a wide 4:1 input voltage
range of 18 to 75VDC. The CXA10 has been designed as a competitive open-frame
alternative for the communications market. The product is supplied in the industry standard
footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection,
short circuit protection and remote on/off. All components are placed in a fully automated
environment. Planar magnetics are used in the design to improve the reliability and reduce
the profile of the DC/DC converter. The series has full international safety approval to
EN60950 and UL1950 reducing system compliance costs, and it has a basic insulation
system from input to output making it suitable for a wide variety of applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage accuracy
±1.0%
Line regulation
(LL to HL)
Singles/dual positives
Dual negatives
Load regulation
(not incl. cross reg.)
Full load to
minimum load
Min. load
All outputs
Ripple and noise
20MHz bandwidth
3.3V and 5.0V
All others
All models
±0.1%
±0.2%
±0.15%
10%
30mV pk-pk
60mV pk-pk
12mV rms
Temperature coefficient
±0.01%/°C
Overvoltage protection
Clamp type
(See table and Notes 3, 4)
Short circuit protection
Short <20mΩ
Hiccup
Transient response
Min. load to FL
±1.0%
Load cross regulation
Min. load to FL (See Note 1)
±5.0%
Continuous
auto. recovery
INPUT SPECIFICATIONS
Input voltage range
48Vin nominal
18 to 75VDC
Input fuse
(See Note 10)
1.5A HRC
Max. input rise
and fall time
48V ETS300 132-2
UVLO turn ON voltage
UVLO turn OFF voltage
(See Note 5)
(See Note 5)
Remote ON/OFF
Logic compatibility
ON
OFF
5V/ms
94%
86%
(See Note 7)
CMOS/TTL/Open Collector
Open circuit
<1VDC
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge (500V)
Fast transients
Radiated immunity
Conducted immunity
EN55022 (See Note 6)
EN55022, external filter,
VDE0878, 48V models
See Application Note 100
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3, 4
EN61000-4-4, level 3, 4
EN61000-4-3, level 3
EN61000-4-6, level 3
Level A
Level B
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and standards
(See Notes 7,8,9,10,11)
Material flammability
Weight
MTBF
(Representative model
48S05 @ 48Vin)
See table
Input/output test voltage
1500VDC
Fixed
400kHz
EN60950, UL1950
CSA C22.2 No. 950
UL94V-0
12g (0.42 oz)
MIL-HDBK-217F
456,621 hours
Parts stress method
Ground Benign @ 25°C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
-40°C to +70°C,
temperature
See curves
Non-operating
-55°C to +105°C
ETS 300 019-2-3
Classes T3.1 to T3.5
Air temperature
Low: IEC 68-2-1
-40°C
High: IEC 68-2-2
+70°C
Change: IEC 68-2-14
-40°C to +70°C
Relative humidity
IEC 68-2-56
10% to 100% RH
IEC 68-2-30
Condensation
Vibration, Class 3M5
IEC68-2-6
2 to 9Hz, 3mm disp.
9 to 200Hz 1g
MIL-STD-202F
Method 204 cond. A
Shock, Class 3M5
IEC-68-2-29
Method 213B cond. A
MIL-STD-202F
File Name: CXA10.PDF Rev: 11 Jan 2002
CXA10 Series
Single and dual output
DC/DC CONVERTERS
10W DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OVERVOLTAGE
PROTECTION (3,4)
OUTPUT
CURRENT (MAX.) (9)
TYPICAL
EFFICIENCY
MODEL
NUMBER (7)
18-75VDC
3.3V
3.9V
2.4A
78%
CXA10-48S3V3
18-75VDC
5.0V
6.8V
2.0A
81%
CXA10-48S05
18-75VDC
12V
16V
0.83A
83%
CXA10-48S12
18-75VDC
±5V
±6.8V
1.0A
81%
CXA10-48D05
18-75VDC
±12V
±16V
0.41A
83%
CXA10-48D12
18-75VDC
±15V
±19V
0.33A
81%
CXA10-48D15
Notes
Negative output voltage deviation when positive load is changed.
Guaranteed minimum output voltage range.
TVS spec: See Application Note 100 on our web site.
On dual output models, OVP protection is on negative outputs only.
With respect to minimum input voltage.
With one external ITW Paktron 4.7µF film capacitor across the input.
For units with optional remote ON/OFF, please add the suffix ‘-S’ to the
model number, e.g. CXA10-48S05-S. Additional alphanumeric suffixes
maybe added to indicate minor modifications not affecting the safety
approvals.
8 Unit provides basic insulation up to the 75VDC maximum input voltage.
9 Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for
the 3V3 model.
10 User must provide 1.5A in line fuse in order to comply with safety
approvals.
11 Maximum temperature on components Q100, CR101, CR102 not to
exceed 120°C. See Application Note 100 for details.
0.400
(10.16)
0.100
(2.54)
1
2
3
4
5
6
7
0.400
(10.16)
0.020
(0.50)
Ø0.040 ±0.002
Dia. (Ø1.02 ±0.05)
3
±0.020 (0.5)
2.000
(50.80)
4
5
0.800
(20.32)
1
2
6
0.600
(15.24)
0.400
(10.16)
0.200
(5.08)
0.300
(7.62)
0.142 (3.60)
± 0.012 (0.3)
OPENFRAME
HEIGHT
± 0.012 (0.3)
0.536 (13.60)
1.000 (25.40)
± 0.020 (0.5)
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
0.394
(10.00)
Max.
ALL DIMENSIONS IN INCHES (mm)
Tolerance on all dimensions of ± 0.005 (0.127)
Unless otherwise specified
PIN CONNECTIONS
DERATING CURVE
(Output Power %)
SINGLE OUTPUT
DUAL OUTPUT
100%
1
+ Input
+ Input
75%
2
– Input
- Input
Remote ON/OFF
Remote ON/OFF
+ Output
+ Output
6*
3
Output Power (%)
PIN NUMBER
50%
25%
27.5%
0%
4
No Pin
Common
-40°C -30°C -20°C -10°C 0°C
10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C
90°C 100°C
AMBIENT TEMPERATURE (°C)
5
- Output
- Output
Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100
* Optional remote ON/OFF pin. Please add the suffix ‘-S’ to the model
number, e.g. CXA10-48S05-S (See Note 7).
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet
www.artesyn.com
File Name: CXA10.PDF Rev: 11 Jan 2002