CXA10 Series Single and dual output DC/DC CONVERTERS • • • • • • • • • 10W DC/DC Converters 1 4:1 input voltage range Approved to EN60950, UL1950, CSA C22.2 No. 950 Operating ambient temperature of -40°C to +70°C in still air High demonstrated reliability with conservative component deratings Complies with ETS 300 019-1-3/2-3 Complies with ETS 300 132-2 input voltage and current requirements Fully compliant with ETS 300 386-1 Pin compatible with NFC10 and BXA10 series Basic insulation system (input to output) The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.3V, 5V, 12V, ±5V, ±12 and ±15V. The series has a wide 4:1 input voltage range of 18 to 75VDC. The CXA10 has been designed as a competitive open-frame alternative for the communications market. The product is supplied in the industry standard footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection, short circuit protection and remote on/off. All components are placed in a fully automated environment. Planar magnetics are used in the design to improve the reliability and reduce the profile of the DC/DC converter. The series has full international safety approval to EN60950 and UL1950 reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage accuracy ±1.0% Line regulation (LL to HL) Singles/dual positives Dual negatives Load regulation (not incl. cross reg.) Full load to minimum load Min. load All outputs Ripple and noise 20MHz bandwidth 3.3V and 5.0V All others All models ±0.1% ±0.2% ±0.15% 10% 30mV pk-pk 60mV pk-pk 12mV rms Temperature coefficient ±0.01%/°C Overvoltage protection Clamp type (See table and Notes 3, 4) Short circuit protection Short <20mΩ Hiccup Transient response Min. load to FL ±1.0% Load cross regulation Min. load to FL (See Note 1) ±5.0% Continuous auto. recovery INPUT SPECIFICATIONS Input voltage range 48Vin nominal 18 to 75VDC Input fuse (See Note 10) 1.5A HRC Max. input rise and fall time 48V ETS300 132-2 UVLO turn ON voltage UVLO turn OFF voltage (See Note 5) (See Note 5) Remote ON/OFF Logic compatibility ON OFF 5V/ms 94% 86% (See Note 7) CMOS/TTL/Open Collector Open circuit <1VDC ETS 300 386-1 table 5 Conducted emissions Radiated emissions ESD air ESD contact Surge (500V) Fast transients Radiated immunity Conducted immunity EN55022 (See Note 6) EN55022, external filter, VDE0878, 48V models See Application Note 100 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3, 4 EN61000-4-4, level 3, 4 EN61000-4-3, level 3 EN61000-4-6, level 3 Level A Level B GENERAL SPECIFICATIONS Efficiency Isolation voltage Switching frequency Approvals and standards (See Notes 7,8,9,10,11) Material flammability Weight MTBF (Representative model 48S05 @ 48Vin) See table Input/output test voltage 1500VDC Fixed 400kHz EN60950, UL1950 CSA C22.2 No. 950 UL94V-0 12g (0.42 oz) MIL-HDBK-217F 456,621 hours Parts stress method Ground Benign @ 25°C ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient -40°C to +70°C, temperature See curves Non-operating -55°C to +105°C ETS 300 019-2-3 Classes T3.1 to T3.5 Air temperature Low: IEC 68-2-1 -40°C High: IEC 68-2-2 +70°C Change: IEC 68-2-14 -40°C to +70°C Relative humidity IEC 68-2-56 10% to 100% RH IEC 68-2-30 Condensation Vibration, Class 3M5 IEC68-2-6 2 to 9Hz, 3mm disp. 9 to 200Hz 1g MIL-STD-202F Method 204 cond. A Shock, Class 3M5 IEC-68-2-29 Method 213B cond. A MIL-STD-202F File Name: CXA10.PDF Rev: 11 Jan 2002 CXA10 Series Single and dual output DC/DC CONVERTERS 10W DC/DC Converters 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm INPUT VOLTAGE OUTPUT VOLTAGE OVERVOLTAGE PROTECTION (3,4) OUTPUT CURRENT (MAX.) (9) TYPICAL EFFICIENCY MODEL NUMBER (7) 18-75VDC 3.3V 3.9V 2.4A 78% CXA10-48S3V3 18-75VDC 5.0V 6.8V 2.0A 81% CXA10-48S05 18-75VDC 12V 16V 0.83A 83% CXA10-48S12 18-75VDC ±5V ±6.8V 1.0A 81% CXA10-48D05 18-75VDC ±12V ±16V 0.41A 83% CXA10-48D12 18-75VDC ±15V ±19V 0.33A 81% CXA10-48D15 Notes Negative output voltage deviation when positive load is changed. Guaranteed minimum output voltage range. TVS spec: See Application Note 100 on our web site. On dual output models, OVP protection is on negative outputs only. With respect to minimum input voltage. With one external ITW Paktron 4.7µF film capacitor across the input. For units with optional remote ON/OFF, please add the suffix ‘-S’ to the model number, e.g. CXA10-48S05-S. Additional alphanumeric suffixes maybe added to indicate minor modifications not affecting the safety approvals. 8 Unit provides basic insulation up to the 75VDC maximum input voltage. 9 Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for the 3V3 model. 10 User must provide 1.5A in line fuse in order to comply with safety approvals. 11 Maximum temperature on components Q100, CR101, CR102 not to exceed 120°C. See Application Note 100 for details. 0.400 (10.16) 0.100 (2.54) 1 2 3 4 5 6 7 0.400 (10.16) 0.020 (0.50) Ø0.040 ±0.002 Dia. (Ø1.02 ±0.05) 3 ±0.020 (0.5) 2.000 (50.80) 4 5 0.800 (20.32) 1 2 6 0.600 (15.24) 0.400 (10.16) 0.200 (5.08) 0.300 (7.62) 0.142 (3.60) ± 0.012 (0.3) OPENFRAME HEIGHT ± 0.012 (0.3) 0.536 (13.60) 1.000 (25.40) ± 0.020 (0.5) CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. 0.394 (10.00) Max. ALL DIMENSIONS IN INCHES (mm) Tolerance on all dimensions of ± 0.005 (0.127) Unless otherwise specified PIN CONNECTIONS DERATING CURVE (Output Power %) SINGLE OUTPUT DUAL OUTPUT 100% 1 + Input + Input 75% 2 – Input - Input Remote ON/OFF Remote ON/OFF + Output + Output 6* 3 Output Power (%) PIN NUMBER 50% 25% 27.5% 0% 4 No Pin Common -40°C -30°C -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C AMBIENT TEMPERATURE (°C) 5 - Output - Output Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100 * Optional remote ON/OFF pin. Please add the suffix ‘-S’ to the model number, e.g. CXA10-48S05-S (See Note 7). Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet www.artesyn.com File Name: CXA10.PDF Rev: 11 Jan 2002