EMERSON-NETWORKPOWER IPM300

ss
w
Embedded Power for
Business-Critical Continuity
Rev. 02.25.11_111
IPM300 Series
1 of 3
IPM300
Dual 48 V ATCA Input
Power Module
Total Power: 300 Watts
Input Voltage: -48 Vdc
Output: 3.3 V Management Bus
5.0 V Management Bus
Electrical Specifications
Input
Special Features
• Optimized footprint for high
density ATCA applications
• Accepts inputs from -48 V and B
Feeds
• Hot Swap and ORing functionality
• 3.3 Vdc and 5.0 Vdc Isolated
Management Power
• Adjustable Hold Up Voltage from
50 to 95 Vdc
• I2C serial bus interface for
monitoring and reporting
• Programmable alarm
thresholds via I2C bus
• Hardware alarms via optoisolators for loss of A or B Feeds
• Comprehensive protection
circuitry - current, voltage and
temperature, inrush current,
reverse polarity
• EU directive 2002/95/EC
compliant for RoHS
-36 V to -75 Vdc
Transient:
-100 Vdc (< 1 ms)
Inrush Current (without EARLY pin):
14 A typ
Recommended EARLY_A/B resistor:
100ohm, surge rated 2010 case size
Inrush Duration:
< 2 ms
Undervoltage Lockout:
-36 < Vin
Overvoltage Lockout:
-78 ≤ Vin < 85 Vdc
Efficiency:
98% @ 300 W
Output
5.0 V Management Bus
3.3 V Management Bus
Nominal Setpoint:
5.0 V
3.35 V
Total Regulation Band1:
4.8 - 5.2 V
3.17 - 3.43 V
Output Current:
0 - 0.15 A
0 - 3.6 A
Current Limit:
130% Io, max (typ)
130% Io, max (typ)
Short Circuit:
Shutdown/Autorecovery
Ripple and Noise2:
60 mVp-p
65 mVp-p
Overvoltage:
External Output Capacitance:
Vo > 13.4 Vdc
TBD
Vo > 5.0 Vdc (typ)
1000 uF max
Isolation Characteristics
Input to Output Isolation Voltage:
2250 Vdc
Input to Output Insulation:
Basic
Environmental Specifications
Safety
• UL/cUL
• TUV
Input Ra­nge:
60950-1 (E186249)
EN60950-1 (B100551485779)
Operating temperature range:
Storage temperature:
MTBF:
-40 °C to +85 °C ambient
-55 °C to +125 °C
> 1 MHrs @ 25 °C 100% Load
ess
w
Embedded Power for
Business-Critical Continuity
Rev. 02.25.11_111
IPM300 Series
2 of 3
Part Number System with Options
Ordering Information
Model Number
IPM300
Input
Output
Output Current
Typical
Note
-36 to -75 Vdc
3.3 V
5.0 V
3.6 A
0.150 A
98% @ -48 V / 300 W
With I2C Interface
Pin Assignments
Pin Number/Pin Name Function
Note
1. -48V A Feed
2. -48V B Feed
3. 48V Return A Feed
4. 48V Return B Feed
Power input from A’ bus
Power input from B’ bus
Power return from A’ bus
Power return from B’ bus
5. Enable A Feed
When connected to RTN A, turns ON isolated open collector A enabled’ device (See Note 3)
6. Enable B Feed
When connected to RTN B, turns ON isolated open collector B enabled’ device (See Note 3)
Connects to ATCAZone 1 connector pin 33 via external 12 A fuse
Connects to ATCAZone 1 connector pin 34 via external 12 A fuse
Connects to ATCAZone 1 connector pin 28 via external 12 A fuse
Connects to ATCAZone 1 connector pin 29 via external 12 A fuse
Connects to ATCAZone 1 connector pin 32 via external 1 A fuse. Used
to signal to management suystem correct board insertion and
presence of A’ bus
Connects to ATCAZone 1 connector pin 27 via external 1 A fuse. Used
to signal to management suystem correct board insertion and
presence of B’ bus
7. SHELF_GND
8. +5.0V Management
Power
9. +3.3V Management
Power
10. Address
11. Data
12. Clock
13. LOGIC_GND
14. ALARM
Shelf/Chassis/Safety Ground
+5.0V Management Power - Blue Service LED
3.3V Isolated Management Power Output
I2C Address
I2C Data
I2C Clock
I2C lines, address strapping
I2C lines, serial data
I2C lines, clock line input
Logic/Secondary/Isolated Ground
Opto-Isolated -48V A/B Feed Loss or Open Fuse Alarm
with respect to LOGIC_GND
15. -48V_OUT
OR’d and Inrush Protected -48VDC Output
16. Holdup Trim
Adjustable 50 to 95 V Hold Up Trim
17. VRTN_OUT
OR’d and Inrush Protected -VRTN Output
18. Holdup Capacitor
Holdup/Bulk Capacitor output voltage
The -48VDC Output connects directly to the Input of an External
DC-DC Converter
The VRTN_Out connects directly to the Input of an External DC-DC
Converter
Notes:
1. Regulation band over line, load and temperature.
2. Measured at 20 MHz with external 22 mF Tantalum in parallel with 1 mF ceramic, 25 V rated low ESR type capacitors across each output.
3. Both Enables (A/B) have to be connected to their respective RTNS to enable the Internal power management I2C.
4. All specifications are typical at nominal line, TA = 25 °C unless otherwise indicated.
5. All specifications are subject to change without notice.
6. Technical Reference Notes and Application Notes should be consulted for complete product details
7. Warranty 2 years.
ess
w
Embedded Power for
Business-Critical Continuity
­Americas
Mechanical Drawing
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
IPM300
58.4
P17 P16 P15
P1
P14
P2
P13
P3
P12
P4
P11
P5
P10
P6
P9
P7
P8
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
36.8
P18
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
TOP VIEW
3.7±0.05
1.0 MIN.
14.73 MAX.
Rev. 02.25.11_111
IPM300 Series
3 of 3
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Ø1±0.05 (18 PLCS)
Ø2±0.1 (18 PLCS)
FRONT VIEW
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
SIDE VIEW
50.80
Emerson Network Power.
The global leader in enabling
business-critical continuity.
31.12
25.40
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
27.94
31.75
35.56
20.32
15.24
10.16
24.13
5.08
3.81
1.27
3.81
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
BOTTOM VIEW
Note: Dimensions in mm.
Note: Dimensions in mm.
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2011 Emerson Electric Co.