EMERSON-NETWORKPOWER NFS40

Embedded Power for
Business-Critical Continuity
Rev.02.15.07
NFS40 Medical
1 of 4
NFS40 Series
SIngle and
triple output
Total Power:
40 - 50W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Single, triple
Special Features
• 5.0 x 3.0 x 1.2 inch package
(1U applications)
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• EN55022, EN55011
conducted noise level A
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Safety
The NFS40-79XXJ models are
approved to UL2601, CSA22.2 No.
125 and IEC601/VDE0750
standards. The NFS40-79XXJ
series is for use in ordinary,
patient-connect applications
under the UL2601 and CSA C22.2
No. 125 standards, and is
authorised for use in non-critical,
non-patient-connect applications
under the IEC601 standards.
The NFS40 medical series is a 40 W universal input ac-dc power
supply on a 5 x 3 inch card with a maximum component height of
1.2 inches for use in medical applications. The NFS40 medical
series has the same generic feature set as the standard NFS40
series but has been designed with lower safety ground leakage
and higher isolation as required for medical safety approval. The
NFS40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air.
Standard features include overvoltage and short-circuit
protection. The series, with full medical safety approval to
EN60601 and UL2601 and the CE mark, meets conducted
emissions EN55022 level A. The NFS40 medical series is designed
for use in low power medical, dental and laboratory applications
such as dialysis machines, monitoring equipment,
instrumentation and infusion pump controls.
Embedded Power for
Business-Critical Continuity
Rev.02.15.07
NFS40 Medical
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
+5 V output on triples
Vout on singles
±5.0%
±5.0%
Line regulation
LL to HL, FL main output
LL to HL, FL auxiliary output
±0.2%
±1.0%
Overshoot/undershoot
At turn-on
Transient response
+5 V
(1.5 A to 3 A step)
Temperature coefficient
All outputs
Overvoltage protection
+ 5V output
Minimum output current
(See Note 10)
Output power limit
Primary power limited
Short circuit protection
0%
±120 mV max dev.
500 μs recovery
Single
Multiple
±0.02%/°C
6.25 ±0.75 Vout
0A
90 W input
power limit
Continuous
Short term
INPUT SPECIFICATIONS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
GENERAL SPECIFICATIONS
Hold-up time
110 Vac
230 Vac
Efficiency
110 Vac, 230 Vac
Isolation voltage
Input/output
Input/chassis
Switching frequency
85-264 Vac
120-370 Vdc
Approvals and
standards
(See Note 12)
Input frequency range
47-440 Hz
Input surge current
Cold start 110 Vac, 60 Hz
Cold start 230 Vac, 50 Hz
Safety ground
leakage current
110 Vac, 60 Hz
230 Vac, 50 Hz
10 A
22 A
MTBF
18 ms
132 ms
70% typical
4000 Vac
1500 Vac
20-10 kHz
VDE0750, IEC601
EN60601-1, UL2601
CSA C22.2 No. 125
Weight
Input voltage range
Level A
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
270 g (9.6 oz)
MIL-HDBK-217E
170,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
18 μA max.
28 μA max.
Operating, see curve
0 °C to +70°C
Non-operating
-40 °C to +85°C
0 ¡C to 50 ¡C ambient temp.,
40 W
convection cooled
0 ¡C to 50 ¡C ambient,
50 W
20 CFM Forced air
50 ¡C to 70 ¡C ambient
Derate linearly
to 50% load
Peak (30 seconds)
60 W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 11)
5-500 Hz
5% to 95% RH
10,000 feet max.
40,000 feet max.
0.75 G peak
Embedded Power for
Business-Critical Continuity
Rev.02.15.07
NFS40 Medical
3 of 4
Specifications Contd.
OUTPUT CURRENT
OUTPUT
VOLTAGE
CONV. MAX (1)
20CFM MAX. (2)
PEAK (3)
RIPPLE (4)
PK-PK
TOTAL
REGULATION (5)
MODEL NUMBERS (13,14)
+5.1 V (VA)
3A
5A
7A
50 mV
±2.0%
NFS40-7908J
+12 V (VB)
2A
2A
3A
120 mV
±5.0%
0.35 A
0A
---
120 mV
±5.0%
-12 V
(6)
+5.1 V (VA)
3A
5A
7A
50 mV
±2.0%
+15 V (VB)
2A
2A
2.5 A
150 mV
+10%/-3.0%
NFS40-7910J
-15 V (6)
0.35 A
0.5 A
---
150 mV
±5.0%
12 V
(7)
3.3 A
4A
5A
120 mV
±2.0%
NFS40-7912J
15 V
(7)
2.6 A
3.3 A
4A
150 mV
±2.0%
NFS40-7915J
24 V (7)
1.6 A
2A
2.5 A
240 mV
±2.0%
NFS40-7924J
+5.1 V
4A
7A
5A
50 mV
±2.0%
NFS40-7928J
+12 V
0.35 A
1A
0.5 A
120 mV
±5.0%
-12 V
0.35 A
1A
0.5 A
120 mV
±5.0%
Notes
AC mating connector
1
2
3
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminal.
4
5
6
7
8
9
10
11
12
13
14
Natural convection cooling, 40 W maximum.
Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
50 MHz bandwidth, peak-to-peak, measured differentially.
Total regulation is defined as the static output regulation at 25 ¡C, including
initial tolerance, load currents within stated limits, and output voltages
adjusted to their factory settings. Also, 0.25 ² IA / IB ² 5.0 to maintain stated
regulation.
A minimum load of 0.5 A is required on the +5 V output to obtain full current
from the negative output.
Single output models have floating outputs which may be referenced as either
positive or negative.
Derating curve is application specific for ambient temperatures >50 ¼C, for
optimum reliability no part of the heatsink should exceed 120 ¼C and no
semiconductor case temperature should exceed 130 ¼C.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Although the minimum output current of the NFS40-79XXJ is 0 A, a 4 W
minimum load is required to achieve design MTBF.
Three orthogonal axes, sweep at 1 octave/min, 5 minute dwell at four major
resonances.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DC mating connector
Molex 09-91-0600 or equivalent with Molex 08-50-0164 or equivalent crimp terminal.
PIN CONNECTIONS
J1
-7908J, 7928J
-7901J
SINGLES
Pin 1
AC Line
AC Line
AC Line
Pin 2
AC Neutral
AC Neutral
AC Neutral
Pin 1
+12 V
+15 V
+Vout
Pin 2
+5.1 V
+5.1 V
+Vout
Pin 3
+5.1 V
+5.1 V
+Vout
Pin 4
Return
Return
Return
Pin 5
Return
Return
Return
Pin 6
-12 V
-15 V
Return
J2
P1
Pin 1
Safety Earth Ground
NO. 3
Embedded Power for
Business-Critical Continuity
Rev.02.15.07
NFS40 Medical
4 of 4
Mechanical Notes
A In order to meet safety requirements, a non-metallic stand-off is mandatory for one hole as specified in the mechanical
drawing above.
B The ground pad of the mounting hole near P1 allows system grounding through a metal stand-off.
C To improve conducted noise, the ground pad of the mounting hole near the output connector should be connected with
the ground pad of the mounting hole near P1. Use metal stand-offs attached to a common metal chassis. This connection
also significantly attenuates common mode noise.
D A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting
hardware. Order part number ‘NFS40 COVER KIT’.
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
0.156 (3.96) Dia.
(4 Places)
NON-METALLIC
STAND-OFF
(SEE NOTE A) Q1
J1
3.00
(76.2)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
5.00
(127.00)
C5
Asia (HK)
MAXIMUM
COMPONENT
HEIGHT 1.2
inches
1
~
N
~
L
F1
2.550
(64.8)
T1
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
J2
www.powerconversion.com
[email protected]
F 3.15A, H 250VAC
P1 (SEE NOTE C)
0.22
(5.59)
0.22 (5.59)
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
4.55
(115.8)
ALL DIMENSIONS IN INCHES (mm)
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.