EMERSON-NETWORKPOWER NFS80

Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS80 Series
1 of 4
NFS80 Series
Quad output
Total Power:
80 - 110W
Input Voltage: 90 - 264VAC
120 - 370VDC
# of Outputs: Quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and
short circuit protection
• 80 W with free air convection
• Adjustable outputs
• Isolated output
• Floating fourth output
• EN55022, EN55011
conducted emissions level B
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-0213
Licence No. 40014677
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
The NFS80 series is a 80 W universal input ac-dc power supply on a
7 x 4.25 inch card. The NFS80 series has two quad output models
with a very high peak capability on the auxiliary outputs for drive
and motor applications. The NFS80 provides 80 W of output
power with free air convection cooling which can be boosted to
110 W with 20 CFM of forced air. Standard features include
overvoltage and short-circuit protection. The series, with full
international safety approval and the CE mark, meets conducted
emissions EN55022 level B. The NFS80 series is designed for use
in low power data networking, computer, telecom and industrial
applications such as servers, PABX's, storage devices, vending
machines and printers.
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS80 Series
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS (11,C)
Output voltage
adjustability
+5 V output on multi’s
Vout on singles
Line regulation
LL to HL, FL
Main output
Auxiliary outputs
Total regulation
(See Note 5)
Overshoot/undershoot
At turn-on
Transient response
+5 V (1 A to 12 A)
Temperature coefficient
All outputs
±0.1% max.
±0.1% max.
See table
0%
±0.02%/°C
+5 V output
Minimum output current
See derating curve
Main output
Auxiliary output
Output power limit
Primary power limit
140% Vout max.
1A
0A
160 W Pin max.
110 W Pout min.
Yes with auto recovery
INPUT SPECIFICATIONS
Input voltage range
Surge
Fast transients
Radiated immunity
Conducted immunity
Hold-up time
Input frequency range
90-264 Vac
120-370 Vdc
47-440 Hz
Input surge current
115 Vac, cold start
230 Vac, cold start
Safety ground
leakage current
110 Vac, 60 Hz
230 Vac, 50 Hz
110 Vac, @ 80 W
110 Vac, @ 110 W
230 Vac, @ 80 W
230 Vac, @ 110 W
Efficiency
Isolation voltage
3000 Vac
1500 Vac
VDE0805, EN60950, IEC950
IEC1010, UL1950
CSA C22.2 No. 950
Weight
600 g (21.18 oz)
MIL-HDBK-217E @ 25 °C
EN55022,FCC part 15
EN55022 FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
Thermal performance
0.2 mA
0.4 mA
Level B
Level B
Perf. criteria 1
Perf. criteria 1
250,000 hours
ENVIRONMENTAL SPECIFICATIONS
Operating, see curve
Non-operating
50 °C to +70 °C
natural convection
50 °C to +70 °C
20 CFM forced air cooling
Relative humidity
Conducted emissions
Radiated emissions
ESD air
ESD contact
35 ms
17 ms
140 ms
100 ms
20-70 kHz
Approvals and
standards
(See Note 10)
19 A
38 A
EMC CHARACTERISTICS (11,C)
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
70% typical
Input/output
Input/chassis
Switching frequency
MTBF (See Note 7)
Universal input
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
GENERAL SPECIFICATIONS
±150 mV peak
1 ms recovery
Overvoltage protection
Short circuit protection
±3.0%
0 °C to +70 °C
–40 °C to +85 °C
Derate
2 W/°C
Derate
2.75 W/°C
5% to 95% RH
Altitude
Operating
Non-operating
Vibration (See Note 9)
5-500 Hz
10,000 feet max.
30,000 feet max.
2.4 G rms approx.
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS80 Series
3 of 4
Specifications Contd.
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX
+5 V (IA)
RIPPLE (4)
TOTAL
REGULATION (5)
MODEL NUMBER (12,13,E)
15 A
50 mV
±2.0%
NFS80-7602J
3A
2.5 A
240 mV
+10.0/-5.0%
6A
3A
120 mV
±3.0%
PEAK (2)
FAN (3)
8A
20 A
+24 V (IB)
2A
+12 V
2.5 A
±12 V
(1)
2.5 A
6A
3A
120 mV
±3.0%
+5 V (IA)
8A
20 A
15 A
50 mV
±2.0%
+24 V (IB)
2A
3A
2.5 A
240 mV
+10.0/-5.0%
+15 V
2.5 A
6A
3A
150 mV
±3.0%
±15 V (6)
2.5 A
6A
3A
150 mV
±3.0%
(6)
NFS80-7606J
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
Natural convection cooling.
Peak output current lasting less than 60 seconds with duty cycle ≤10%. During
peak loading, outputs may exceed total regulation limits.
Forced air cooling, 20 CFM @ 1 atmosphere.
50 MHz bandwidth, peak-to-peak, measured differentially.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, for stated
regulation on the +24 V output, IA / IB ≤ 5.
Pins 10 and 11 are a floating output, which can be referenced as either positive
or negative. Pin 10 is positive with respect to pin 11. Either pin 10 or 11 must
be connected to return (pins 4-7) for proper operation.
Derating curve is application specific for ambient temperatures > 50 °C, for
optimum reliability, no part of the heatsink should exceed 110 ºC and no
semiconductor case temperature should exceed 115 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, random vibration, 10 minute test for each axis.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
For EMI compliance unit may need to be mounted on a metal chassis.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
110W
20 CFM FORCED AIR COOLING
80W
NATURAL
CONVECTION
COOLING
55W
40W
5W MINIMUM LOAD NECESSARY
5W
0°C 10°C
20°C
30°C
40°C
50°C
60°C
70°C
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS80 Series
4 of 4
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.