ARTESYN NLP40

NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
40-50W AC/DC Universal Input Switch Mode Power Supplies
1
4.25 x 2.5 x 1.15 inch package (1U applications)
Smallest industry package
Overvoltage and short circuit protection
40W with free air convection
EN55022, EN55011 conducted emission level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
UL, VDE and CSA safety approvals
The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This
product is the smallest standard 40W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40W of output power with free air convection
cooling which can be boosted to 50W with 20CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval
and the CE mark, meets conducted noise EN55022 level B and has immunity compliance
to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals,
LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic
feature set of the NLP40 series with industry standard output configurations provides a
solution for most low power applications including many industrial applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
25% step at 0.1A/µs
Temperature coefficient
±2.0%
±5.0%
1.0s, max.
5.0% max. dev.,
1ms rec. to 1.0%
±0.02%/°C
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Single
Multiple
135%, ±15%
Continuous
0A
(See Note 5)
INPUT SPECIFICATIONS
Input voltage range
(See Note 9)
120VAC
230VAC
12ms @ 40W
20ms @ 40W
Efficiency
75% typical
Isolation voltage
Input/output
Input/chassis
Switching frequency
Fixed
Approvals and
standards (See Note 8)
65kHz, ±5kHz
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Weight
MTBF
3000VAC
1500VAC
200g (7.06oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Universal input
Input frequency range
90 to 264VAC
120 to 370VDC
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
0°C to +70°C
(see derating curve)
Non-operating
-40°C to +70°C
50°C to 70°C ambient,
Derate to
convection cooled
50% load
0°C to 50°C, ambient,
40W
convection cooled
0°C to 50°C ambient,
50W
20CFM forced air
Peak (0°C to +50°C, 60s) (See Note 2)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 4)
5Hz to 500Hz
Shock
per MIL-STD-810E
47Hz to 440Hz
Input surge current
120VAC, cold start
230VAC, cold start
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Input current
120VAC
230VAC
Input fuse
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Hold-up time
15A max.
30A max.
0.2mA
0.4mA
1.4A rms
0.7A rms
250VAC H 3.15A
(10)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
level B
level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
516.4 Part IV
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
RIPPLE
MAX
(1)
PEAK
(2)
FAN
TOTAL
(3)
(1)
MODEL NUMBER
REGULATION
+5V (IA)
4.0A
5.0A
4.5A
50mV
±2.0%
+12V (IB)
2.0A
3.0A
3.0A
120mV
±5.0%
–12V (IC)
0.2A
1.0A
0.5A
120mV
±5.0%
+5V (IA)
4.0A
5.0A
4.5A
50mV
±2.0%
+15V (IB)
1.6A
2.0A
2.0A
150mV
±5.0%
NLP40-7608
(5)
NLP40-7610
(5)
NLP40-7627
(5)
NLP40-7629
(5)
–15V (IC)
0.2A
1.0A
0.5A
150mV
±5.0%
+12V (IA)
1.8A
2.2A
2.1A
120mV
±2.0%
-12V (IB)
1.8A
2.2A
2.1A
120mV
±5.0%
+5V (IA)
4.0A
5.0A
4.5A
50mV
±2.0%
+12V (IB)
2.0A
3.0A
3.0A
120mV
±5.0%
5V
8.0A
10A
9.0A
50mV
±2.0%
NLP40-7605
12V
3.3A
4.5A
4.0A
120mV
±2.0%
NLP40-7612
15V
2.6A
3.6A
3.3A
150mV
±2.0%
NLP40-7615
24V
1.6A
2.5A
2.0A
240mV
±2.0%
NLP40-7624
48V
0.8A
1.1A
1.0A
300mV
±2.0%
NLP40-7617
Notes
DERATING CURVE
Output Power (Watts)
Maximum output power is 40W for natural convection cooling. With 20CFM
fan cooling, the maximum output power is 50W.
50W
2 Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
20 CFM FORCED AIR COOLING
3 Figure is peak-to-peak. Output noise measurements are made across a
40W
50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF
capacitor.
4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
5 For multiple output units (except -7627) to maintain stated regulation then:
NATURAL
25W
0.25 ≤ IA / IB ≤ 5, for IB > 0.3A
CONVECTION
0.50 ≤ IA / IB ≤ 5, for IB < 0.3A
COOLING
20W
For maximum output current I(C) on triple output models, i.e. for
IC = IMax., IA min. ≥ 0.5A and IA ≥ IB.
For NLP40-7627 only, to maintain stated regulation then:
0.5 ≤ IA / IB ≤ 2.
6 For optimum reliability, no part of the heatsink should exceed 120°C, and
no semiconductor case temperature should exceed 130°C.
7 CAUTION: Allow a minimum of 1 second after disconnecting line power
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
when making thermal measurements.
8 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9 When the input voltage is <90VAC the operating range is 0°C to +40°C.
10 For system EMI compliance, a ground choke may be
required before connecting the ground wire to the
INPUT
OUTPUT PIN CONNECTIONS
chassis. It is recommended that this ground choke be
PIN CONNECTIONS
J2
SINGLE
DUAL
TRIPLE
placed as close as possible to the systems AC inlet to
eliminate noise pick-up in the system.
J1
1
Pin 1
+Vout
V (B)
V (B)
Pin 1
AC Line
Pin 2
+Vout
V (A)
V (A)
Pin 2
No Pin
Pin 3
+Vout
V (A)
V (A)
Pin 3
AC Neutral
Pin 4
Return
Return
Return
P1
Pin 5
Return
Return
Return
Pin 1
Safety Ground
Pin 6
Return
Return
V (C)
www.artesyn.com
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25
(107.95)
0.125
(3.175)
4.00
(101.60)
J1
F1
N
1
L
2.50
(63.50)
J2
P1
2.25
(57.15)
T1
C5
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
TOLERANCE: .xxx ± 0.005"
.xx
± 0.02"
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105
or equivalent crimp terminals.
DC (J2) mating connector type
Molex 09-50-3061 with Triurcon 6838 or equivalent
crimp terminals.
Note: The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
DC (J2) connector type
Molex 26-60-4060 type.
Mounting
Hole Diameter
0.138 (3.50) Typical
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. pending
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP40.PDF Rev: 01 Jan 2000