NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES • • • • • • • 40-50W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40W of output power with free air convection cooling which can be boosted to 50W with 20CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation (Line and load) Main output Auxiliary outputs Rise time At turn-on Transient response Main output 25% step at 0.1A/µs Temperature coefficient ±2.0% ±5.0% 1.0s, max. 5.0% max. dev., 1ms rec. to 1.0% ±0.02%/°C Overvoltage protection Main outputs Short circuit protection Cyclic operation Minimum output current Single Multiple 135%, ±15% Continuous 0A (See Note 5) INPUT SPECIFICATIONS Input voltage range (See Note 9) 120VAC 230VAC 12ms @ 40W 20ms @ 40W Efficiency 75% typical Isolation voltage Input/output Input/chassis Switching frequency Fixed Approvals and standards (See Note 8) 65kHz, ±5kHz EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 Weight MTBF 3000VAC 1500VAC 200g (7.06oz) MIL-HDBK-217F 150,000 hours min. ENVIRONMENTAL SPECIFICATIONS Universal input Input frequency range 90 to 264VAC 120 to 370VDC Thermal performance (See Notes 6, 7, 9) Operating ambient, 0°C to +70°C (see derating curve) Non-operating -40°C to +70°C 50°C to 70°C ambient, Derate to convection cooled 50% load 0°C to 50°C, ambient, 40W convection cooled 0°C to 50°C ambient, 50W 20CFM forced air Peak (0°C to +50°C, 60s) (See Note 2) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 4) 5Hz to 500Hz Shock per MIL-STD-810E 47Hz to 440Hz Input surge current 120VAC, cold start 230VAC, cold start Safety ground leakage current 120VAC, 60Hz 230VAC, 50Hz Input current 120VAC 230VAC Input fuse UL/IEC127 EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity Hold-up time 15A max. 30A max. 0.2mA 0.4mA 1.4A rms 0.7A rms 250VAC H 3.15A (10) EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV File Name: NLP40.PDF Rev: 01 Jan 2000 NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT VOLTAGE RIPPLE MAX (1) PEAK (2) FAN TOTAL (3) (1) MODEL NUMBER REGULATION +5V (IA) 4.0A 5.0A 4.5A 50mV ±2.0% +12V (IB) 2.0A 3.0A 3.0A 120mV ±5.0% –12V (IC) 0.2A 1.0A 0.5A 120mV ±5.0% +5V (IA) 4.0A 5.0A 4.5A 50mV ±2.0% +15V (IB) 1.6A 2.0A 2.0A 150mV ±5.0% NLP40-7608 (5) NLP40-7610 (5) NLP40-7627 (5) NLP40-7629 (5) –15V (IC) 0.2A 1.0A 0.5A 150mV ±5.0% +12V (IA) 1.8A 2.2A 2.1A 120mV ±2.0% -12V (IB) 1.8A 2.2A 2.1A 120mV ±5.0% +5V (IA) 4.0A 5.0A 4.5A 50mV ±2.0% +12V (IB) 2.0A 3.0A 3.0A 120mV ±5.0% 5V 8.0A 10A 9.0A 50mV ±2.0% NLP40-7605 12V 3.3A 4.5A 4.0A 120mV ±2.0% NLP40-7612 15V 2.6A 3.6A 3.3A 150mV ±2.0% NLP40-7615 24V 1.6A 2.5A 2.0A 240mV ±2.0% NLP40-7624 48V 0.8A 1.1A 1.0A 300mV ±2.0% NLP40-7617 Notes DERATING CURVE Output Power (Watts) Maximum output power is 40W for natural convection cooling. With 20CFM fan cooling, the maximum output power is 50W. 50W 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 20 CFM FORCED AIR COOLING 3 Figure is peak-to-peak. Output noise measurements are made across a 40W 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. 5 For multiple output units (except -7627) to maintain stated regulation then: NATURAL 25W 0.25 ≤ IA / IB ≤ 5, for IB > 0.3A CONVECTION 0.50 ≤ IA / IB ≤ 5, for IB < 0.3A COOLING 20W For maximum output current I(C) on triple output models, i.e. for IC = IMax., IA min. ≥ 0.5A and IA ≥ IB. For NLP40-7627 only, to maintain stated regulation then: 0.5 ≤ IA / IB ≤ 2. 6 For optimum reliability, no part of the heatsink should exceed 120°C, and no semiconductor case temperature should exceed 130°C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is <90VAC the operating range is 0°C to +40°C. 10 For system EMI compliance, a ground choke may be required before connecting the ground wire to the INPUT OUTPUT PIN CONNECTIONS chassis. It is recommended that this ground choke be PIN CONNECTIONS J2 SINGLE DUAL TRIPLE placed as close as possible to the systems AC inlet to eliminate noise pick-up in the system. J1 1 Pin 1 +Vout V (B) V (B) Pin 1 AC Line Pin 2 +Vout V (A) V (A) Pin 2 No Pin Pin 3 +Vout V (A) V (A) Pin 3 AC Neutral Pin 4 Return Return Return P1 Pin 5 Return Return Return Pin 1 Safety Ground Pin 6 Return Return V (C) www.artesyn.com File Name: NLP40.PDF Rev: 01 Jan 2000 NLP40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm 4.25 (107.95) 0.125 (3.175) 4.00 (101.60) J1 F1 N 1 L 2.50 (63.50) J2 P1 2.25 (57.15) T1 C5 ALL DIMENSIONS IN INCHES (mm) MAXIMUM COMPONENT HEIGHT 1.15 (29.21) TOLERANCE: .xxx ± 0.005" .xx ± 0.02" Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 type. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals. Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40 and NAN40. DC (J2) connector type Molex 26-60-4060 type. Mounting Hole Diameter 0.138 (3.50) Typical International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. pending UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: NLP40.PDF Rev: 01 Jan 2000