ARTESYN NFS80

NFS80 Series
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
•
•
1
80-110 W AC-DC Universal Input Switch Mode Power Supplies
7.0 x 4.25 x 1.8 inch package
Overvoltage and short circuit protection
80 W with free air convection
Adjustable outputs
Isolated output
Floating fourth output
EN55022, EN55011 conducted emissions level B
UL, VDE and CSA safety approvals
Available RoHS compliant
The NFS80 series is a 80 W universal input ac-dc power supply on a 7 x 4.25
inch card. The NFS80 series has two quad output models with a very high peak
capability on the auxiliary outputs for drive and motor applications. The NFS80
provides 80 W of output power with free air convection cooling which can be
boosted to 110 W with 20 CFM of forced air. Standard features include
overvoltage and short-circuit protection. The series, with full international safety
approval and the CE mark, meets conducted emissions EN55022 level B. The
NFS80 series is designed for use in low power data networking, computer,
telecom and industrial applications such as servers, PABX's, storage devices,
vending machines and printers.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Output voltage
adjustability
+5 V output on multi’s
Vout on singles
Line regulation
LL to HL, FL
Main output
Auxiliary outputs
Total regulation
(See Note 5)
Overshoot/undershoot
At turn-on
Transient response
+5 V (1 A to 12 A)
Temperature coefficient
All outputs
Overvoltage protection
+5 V output
Minimum output current
See derating curve
Main output
Auxiliary output
Output power limit
Primary power limit
Short circuit protection
±3.0%
±0.1% max.
±0.1% max.
See table
0%
±0.02%/°C
140% Vout max.
1A
0A
160 W Pin max.
110 W Pout min.
Yes with auto recovery
Hold-up time
Input frequency range
90-264 Vac
120-370 Vdc
47-440 Hz
Input surge current
115 Vac, cold start
230 Vac, cold start
Safety ground
leakage current
110 Vac, 60 Hz
230 Vac, 50 Hz
110
110
230
230
Vac,
Vac,
Vac,
Vac,
@
@
@
@
Isolation voltage
Input/output
Input/chassis
Switching frequency
Conducted emissions
Radiated emissions
ESD air
ESD contact
EN55022,FCC part 15
EN55022 FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
criteria
criteria
criteria
criteria
1
1
1
1
35
17
140
100
ms
ms
ms
ms
3000 Vac
1500 Vac
VDE0805, EN60950, IEC950
IEC1010, UL1950
CSA C22.2 No. 950
Weight
600 g (21.18 oz)
MIL-HDBK-217E @ 25 °C 250,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
0.2 mA
0.4 mA
Level B
Level B
Perf. criteria 1
Perf. criteria 1
Perf.
Perf.
Perf.
Perf.
20-70 kHz
Approvals and
standards
(See Note 10)
19 A
38 A
(11,C)
3
3
3
3
70% typical
Operating, see curve
0 °C to +70 °C
Non-operating
–40 °C to +85 °C
50 °C to +70 °C
Derate
natural convection
2 W/°C
50 °C to +70 °C
Derate
20 CFM forced air cooling
2.75 W/°C
Relative humidity
EMC CHARACTERISTICS
level
level
level
level
80 W
110 W
80 W
110 W
Efficiency
MTBF (See Note 7)
Universal input
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
GENERAL SPECIFICATIONS
±150 mV peak
1 ms recovery
INPUT SPECIFICATIONS
Input voltage range
Surge
Fast transients
Radiated immunity
Conducted immunity
(11,C)
5% to 95% RH
Altitude
Operating
Non-operating
Vibration (See Note 9)
5-500 Hz
10,000 feet max.
30,000 feet max.
2.4 G rms approx.
File Name: nfs80.pdf Rev (02): 08 Nov 2005
NFS80 Series
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT
VOLTAGE
+5 V (IA)
OUTPUT CURRENTS
MAX
(1)
8A
PEAK
(2)
FAN
(3)
20 A
15 A
RIPPLE
(4)
TOTAL
REGULATION
50 mV
±2.0%
2A
3A
2.5 A
240 mV
+10.0/-5.0%
+12 V
2.5 A
6A
3A
120 mV
±3.0%
±12 V (6)
2.5 A
6A
3A
120 mV
±3.0%
+5 V (IA)
8A
20 A
15 A
50 mV
±2.0%
MODEL NUMBER (12,13,E)
NFS80-7606J
+24 V (IB)
2A
3A
2.5 A
240 mV
+10.0/-5.0%
+15 V
2.5 A
6A
3A
150 mV
±3.0%
2.5 A
6A
3A
150 mV
±3.0%
(6)
(5)
NFS80-7602J
+24 V (IB)
±15 V
2
80-110 W AC-DC Universal Input Switch Mode Power Supplies
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
Natural convection cooling.
Peak output current lasting less than 60 seconds with duty cycle ≤10%.
During peak loading, outputs may exceed total regulation limits.
Forced air cooling, 20 CFM @ 1 atmosphere.
50 MHz bandwidth, peak-to-peak, measured differentially.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, for
stated regulation on the +24 V output, IA / IB ≤ 5.
Pins 10 and 11 are a floating output, which can be referenced as either
positive or negative. Pin 10 is positive with respect to pin 11. Either pin 10
or 11 must be connected to return (pins 4-7) for proper operation.
Derating curve is application specific for ambient temperatures > 50 °C, for
optimum reliability, no part of the heatsink should exceed 110 ºC and no
semiconductor case temperature should exceed 115 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, random vibration, 10 minute test for each axis.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
For EMI compliance unit may need to be mounted on a metal chassis.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
110W
20 CFM FORCED AIR COOLING
80W
NATURAL
CONVECTION
COOLING
55W
40W
5W MINIMUM LOAD NECESSARY
5W
0°C 10°C
20°C
30°C
40°C
50°C
60°C
70°C
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-0213
Licence No. 40014677
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
File Name: nfs80.pdf Rev (02): 08 Nov 2005
NFS80 Series
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
80-110 W AC-DC Universal Input Switch Mode Power Supplies
3
0.475
±0.010
(12.07)
1.00
±0.005
(25.4)
1.80 (45.72)
Max.
0.050
±0.020
(1.27)
3.35 ±0.015 (85.09)
C
6-32 UNC
(4 Places)
1.55 ±0.005
(39.37)
Pin 1
Voltage Adjust
J2
4.250
±0.020
(107.95)
T1
3.750
±0.005
(95.25)
Pin 1
L1
J1
C6
F1
0.250
±0.010
(6.35)
6.50 ±0.005 (165.1)
0.156 (3.962)
Dia. Hole
(4 Places)
5A, 250 VAC
7.00 ±0.020 (177.8)
0.250
±0.010
(6.35)
ALL DIMENSIONS IN INCHES (mm)
Mechanical Notes
A Either metallic or non-metallic stand-offs can be used in all four mounting
holes without affecting safety approval. The diameter of metal stand-offs, if
used, must not exceed 0.212 inches (5.4 mm).
B It is always advisable to attach the power supply heat sink to another
thermal dissipator (such as a chassis, a finned heat sink, etc.) The resulting
temperature decrease of heat sink-mounted components will improve
power supply lifetime.
C The heat sink is grounded, and allows system grounding when
mechanically connected to the system chassis. Alternatively, the ground
pad encircling the mounting hole near J1, allows system grounding through
a metal stand-off to the system chassis.
D The supply must be mechanically supported using the PCB mounting holes
and may be additionally supported by the heat sink mounting holes.
E A standard L-bracket and cover is available for mounting which contains all
screws, connectors and mounting hardware. Two different kits are
available, order part number ‘NFS110 COVER KIT’ or ‘NFS110C’.
AC (J1) connector
Molex 09-50-3051 (with second and fourth pins removed) or Molex 09-910500 mating connector with 2478 or equivalent crimp terminals.
DC (J2) connector
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or
equivalent crimp terminals.
J1
Pin 1
Pin 2
Pin 3
J2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10 (6)
Pin 11 (6)
Pin 12
Pin 13
PIN CONNECTIONS
NFS80-7602J
NFS80-7606J
AC Ground
AC Ground
AC Neutral
AC Neutal
AC Line
AC Line
NFS80-7602J
NFS80-7606J
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
Return
Return
Return
Return
Return
Return
Return
Return
+12 V
+15 V
+12 V
+15 V
-12 V Return
-15 V Return
-12 V
-15 V
Removed for Key
Removed for Key
+24 V
+24 V
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: nfs80.pdf Rev (02): 08 Nov 2005