NFS80 Series Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES • • • • • • • • • 1 80-110 W AC-DC Universal Input Switch Mode Power Supplies 7.0 x 4.25 x 1.8 inch package Overvoltage and short circuit protection 80 W with free air convection Adjustable outputs Isolated output Floating fourth output EN55022, EN55011 conducted emissions level B UL, VDE and CSA safety approvals Available RoHS compliant The NFS80 series is a 80 W universal input ac-dc power supply on a 7 x 4.25 inch card. The NFS80 series has two quad output models with a very high peak capability on the auxiliary outputs for drive and motor applications. The NFS80 provides 80 W of output power with free air convection cooling which can be boosted to 110 W with 20 CFM of forced air. Standard features include overvoltage and short-circuit protection. The series, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The NFS80 series is designed for use in low power data networking, computer, telecom and industrial applications such as servers, PABX's, storage devices, vending machines and printers. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 °C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Output voltage adjustability +5 V output on multi’s Vout on singles Line regulation LL to HL, FL Main output Auxiliary outputs Total regulation (See Note 5) Overshoot/undershoot At turn-on Transient response +5 V (1 A to 12 A) Temperature coefficient All outputs Overvoltage protection +5 V output Minimum output current See derating curve Main output Auxiliary output Output power limit Primary power limit Short circuit protection ±3.0% ±0.1% max. ±0.1% max. See table 0% ±0.02%/°C 140% Vout max. 1A 0A 160 W Pin max. 110 W Pout min. Yes with auto recovery Hold-up time Input frequency range 90-264 Vac 120-370 Vdc 47-440 Hz Input surge current 115 Vac, cold start 230 Vac, cold start Safety ground leakage current 110 Vac, 60 Hz 230 Vac, 50 Hz 110 110 230 230 Vac, Vac, Vac, Vac, @ @ @ @ Isolation voltage Input/output Input/chassis Switching frequency Conducted emissions Radiated emissions ESD air ESD contact EN55022,FCC part 15 EN55022 FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 criteria criteria criteria criteria 1 1 1 1 35 17 140 100 ms ms ms ms 3000 Vac 1500 Vac VDE0805, EN60950, IEC950 IEC1010, UL1950 CSA C22.2 No. 950 Weight 600 g (21.18 oz) MIL-HDBK-217E @ 25 °C 250,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance 0.2 mA 0.4 mA Level B Level B Perf. criteria 1 Perf. criteria 1 Perf. Perf. Perf. Perf. 20-70 kHz Approvals and standards (See Note 10) 19 A 38 A (11,C) 3 3 3 3 70% typical Operating, see curve 0 °C to +70 °C Non-operating –40 °C to +85 °C 50 °C to +70 °C Derate natural convection 2 W/°C 50 °C to +70 °C Derate 20 CFM forced air cooling 2.75 W/°C Relative humidity EMC CHARACTERISTICS level level level level 80 W 110 W 80 W 110 W Efficiency MTBF (See Note 7) Universal input EN61000-4-5, EN61000-4-4, EN61000-4-3, EN61000-4-6, GENERAL SPECIFICATIONS ±150 mV peak 1 ms recovery INPUT SPECIFICATIONS Input voltage range Surge Fast transients Radiated immunity Conducted immunity (11,C) 5% to 95% RH Altitude Operating Non-operating Vibration (See Note 9) 5-500 Hz 10,000 feet max. 30,000 feet max. 2.4 G rms approx. File Name: nfs80.pdf Rev (02): 08 Nov 2005 NFS80 Series Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES OUTPUT VOLTAGE +5 V (IA) OUTPUT CURRENTS MAX (1) 8A PEAK (2) FAN (3) 20 A 15 A RIPPLE (4) TOTAL REGULATION 50 mV ±2.0% 2A 3A 2.5 A 240 mV +10.0/-5.0% +12 V 2.5 A 6A 3A 120 mV ±3.0% ±12 V (6) 2.5 A 6A 3A 120 mV ±3.0% +5 V (IA) 8A 20 A 15 A 50 mV ±2.0% MODEL NUMBER (12,13,E) NFS80-7606J +24 V (IB) 2A 3A 2.5 A 240 mV +10.0/-5.0% +15 V 2.5 A 6A 3A 150 mV ±3.0% 2.5 A 6A 3A 150 mV ±3.0% (6) (5) NFS80-7602J +24 V (IB) ±15 V 2 80-110 W AC-DC Universal Input Switch Mode Power Supplies Notes 1 2 3 4 5 6 7 8 9 10 11 12 13 Natural convection cooling. Peak output current lasting less than 60 seconds with duty cycle ≤10%. During peak loading, outputs may exceed total regulation limits. Forced air cooling, 20 CFM @ 1 atmosphere. 50 MHz bandwidth, peak-to-peak, measured differentially. Total regulation is defined as the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits, load currents within stated limits, and output voltages adjusted to their factory settings. Also, for stated regulation on the +24 V output, IA / IB ≤ 5. Pins 10 and 11 are a floating output, which can be referenced as either positive or negative. Pin 10 is positive with respect to pin 11. Either pin 10 or 11 must be connected to return (pins 4-7) for proper operation. Derating curve is application specific for ambient temperatures > 50 °C, for optimum reliability, no part of the heatsink should exceed 110 ºC and no semiconductor case temperature should exceed 115 ºC. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. Three orthogonal axes, random vibration, 10 minute test for each axis. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. For EMI compliance unit may need to be mounted on a metal chassis. The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. DERATING CURVE Output Power (Watts) 110W 20 CFM FORCED AIR COOLING 80W NATURAL CONVECTION COOLING 55W 40W 5W MINIMUM LOAD NECESSARY 5W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-0213 Licence No. 40014677 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C File Name: nfs80.pdf Rev (02): 08 Nov 2005 NFS80 Series Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC-DC Universal Input Switch Mode Power Supplies 3 0.475 ±0.010 (12.07) 1.00 ±0.005 (25.4) 1.80 (45.72) Max. 0.050 ±0.020 (1.27) 3.35 ±0.015 (85.09) C 6-32 UNC (4 Places) 1.55 ±0.005 (39.37) Pin 1 Voltage Adjust J2 4.250 ±0.020 (107.95) T1 3.750 ±0.005 (95.25) Pin 1 L1 J1 C6 F1 0.250 ±0.010 (6.35) 6.50 ±0.005 (165.1) 0.156 (3.962) Dia. Hole (4 Places) 5A, 250 VAC 7.00 ±0.020 (177.8) 0.250 ±0.010 (6.35) ALL DIMENSIONS IN INCHES (mm) Mechanical Notes A Either metallic or non-metallic stand-offs can be used in all four mounting holes without affecting safety approval. The diameter of metal stand-offs, if used, must not exceed 0.212 inches (5.4 mm). B It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis, a finned heat sink, etc.) The resulting temperature decrease of heat sink-mounted components will improve power supply lifetime. C The heat sink is grounded, and allows system grounding when mechanically connected to the system chassis. Alternatively, the ground pad encircling the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heat sink mounting holes. E A standard L-bracket and cover is available for mounting which contains all screws, connectors and mounting hardware. Two different kits are available, order part number ‘NFS110 COVER KIT’ or ‘NFS110C’. AC (J1) connector Molex 09-50-3051 (with second and fourth pins removed) or Molex 09-910500 mating connector with 2478 or equivalent crimp terminals. DC (J2) connector Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals. J1 Pin 1 Pin 2 Pin 3 J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 (6) Pin 11 (6) Pin 12 Pin 13 PIN CONNECTIONS NFS80-7602J NFS80-7606J AC Ground AC Ground AC Neutral AC Neutal AC Line AC Line NFS80-7602J NFS80-7606J +5 V +5 V +5 V +5 V +5 V +5 V Return Return Return Return Return Return Return Return +12 V +15 V +12 V +15 V -12 V Return -15 V Return -12 V -15 V Removed for Key Removed for Key +24 V +24 V Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: nfs80.pdf Rev (02): 08 Nov 2005