EPIGAP ELD-470-324

LED - Lamp
ELD-470-324
16.11.2007
rev. 02
Radiation
Type
Technology
Case
Blue
Standard
InGaN/Al2O3
3 mm plastic lens
Description
High-power, high-speed blue LED with lens,
standard 3 mm package allows compact design,
housing without standoff leads
30,0
±1,0
Ø3
4,3
Anode
0,7
1,5
0,5
0,65
Ø 2,9
2,5
Ø 2,8
Note: Special packages with standoff available on request
Applications
1,0
Optical communications, safety equipment,
automation
Maximum Ratings
Tamb = 25°C, unless otherwise specified
Test сonditions
Parameter
Symbol
Value
Unit
IF
30
mA
IFM
300
mA
PD
120
mW
Operating temperature range
Tamb
-20 to +80
°C
Storage temperature range
Tstg
-30 to +100
°C
TSd
260
°C
Typ
Max
Unit
3.5
4
V
Forward current (DC)
(tP ≤ 50 µs, tP /T = 1/2)
Peak forward current
Power dissipation
t ≤ 5 s, 3 mm from case
Soldering temperature
Optical and Electrical Characteristics
Tamb = 25°C, unless otherwise specified
Test
Parameter
conditions
IF = 20 mA
Forward voltage
Symbol
Min
VF
Reverse voltage
IR = 100 µA
VR
Luminous intensity
IF = 20 mA
Iv
300
mcd
Peak wavelength
IF = 20 mA
λp
468
nm
Spectral bandwidth at 50%
IF = 20 mA
∆λ0.5
35
nm
Viewing angle
IF = 20 mA
ϕ
80
deg.
Switching time
IF = 20 mA
tr, tf
40
ns
5
V
*measured after 30s current flow
Note: All measurements carried out on EPIGAP equipment
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
1 of 2
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545
LED - Lamp
ELD-470-324
16.11.2007
40
150
30
IF (mA)
e
Φ (%)
Radiant power Intensity (%)
200
100
50
0
Forward current vs. forward voltage (typical)
20
10
0
10
20
30
0
40
0
1
2
SPEKTRAL OUTPUT
Ambient Temperature vs. maximal forward current
80
Max. forward current (mA)
RELATIVE POWER OUTPUT(%)
4
40
100
60
40
20
0
300
350
400
450
500
550
30
20
10
0
-30
600
LIMINOUS INTENSITY vs TEMPERATUR at I = 10 mA
F
30
60
90
4,0
FORWARD VOLTAGE vs TEMPERATURE IF=10mA
3,5
FORWARD VOLTAGE(V)
120
100
80
60
40
3,0
2,5
2,0
1,5
20
0
-30°
0
Ambient Temperature (°C)
WAVELENGTH (nm)
LIMINOUS INTENSYTY (%)
3
UF (V)
IF (mA)
140
rev. 02
0°
30°
60°
AMBIENT TEMPERATURE (°C)
90°
1,0
-30
0
30
60
90
AMBIENT TEMPERATUR(°C)
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
2 of 2
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545