LED - Lamp ELD-655-533-1 16.11.2007 rev. 05 Radiation Type Technology Case Red DDH AlGaAs/AlGaAs 5 mm plastic lens Description High-power, high-speed deep red LED in standard 5 mm package, housing without standoff leads 9 - 0,5 6 - 0,3 1,1 - 0,1 2,54 5,3 - 0,3 0,8 - 0,4 Anode 2 - 1,0 Applications 0,6 - 0,2 32,5 Optical communications, safety equipment, automation Maximum Ratings Tamb = 25°C, unless otherwise specified Parameter Test сonditions Symbol Value Unit IF 30 mA IFM 100 mA Operating temperature range Tamb -20 to +85 °C Storage temperature range Tstg -55 to +100 °C Junction temperature TJ 100 °C Tsd 260 °C Typ Max Unit 2.0 2.3 V Forward current (DC) (tP ≤ 50 µs, tP /T = 1/2) Peak forward current t ≤ 5 s, 3 mm from case Soldering temperature Optical and Electrical Characteristics Tamb = 25°C, unless otherwise specified Test Parameter conditions IF = 20 mA Forward voltage Symbol Min VF Reverse voltage IR = 10 µA VR 5 Radiant power IF = 20 mA Φe 3 4 mW Luminous intensity IF = 20 mA Iv 700 1000 mcd Radiant intensity IF = 20 mA Ie 15 20 mW/sr Peak wavelength IF = 20 mA λp 650 655 Dominant wavelength IF = 20 mA λd 640 nm Spectral bandwidth at 50% IF = 20 mA ∆λ0.5 22 nm Viewing angle IF = 20 mA ϕ 20 deg. Switching time IF = 20 mA tr, tf 70 ns V 660 nm *measured after 30s current flow Note: All measurements carried out on EPIGAP equipment We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 1 of 2 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 LED - Lamp ELD-655-533-1 16.11.2007 rev. 05 Remarks concerning optical radiation safety* Up to maximum forward current, at continuous operation, this LED may be classified as LED product Class 1 , according to standard IEC 60825-1:A2. Class 1 products are safe to eyes and skin under reasonably predictable conditions. This implicates a direct observation of the light beam by means of optical instruments. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed current or altering the light beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 2 of 2 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545