54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 • • • • • • 54AC11241 . . . JT PACKAGE 74AC11241 . . . DB, DW OR NT PACKAGE 3-State Outputs Drive Bus Lines or Buffer Memory Address Registers Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise EPIC (Enhanced-Performance Implanted CMOS) 1-mm Process 500-mA Typical Latch-Up Immunity at 125°C Package Options Include Plastic SmallOutline Packages, Plastic Shrink Small-Outline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs (TOP VIEW) 1Y1 1Y2 1Y3 1Y4 GND GND GND GND 2Y1 2Y2 2Y3 2Y4 t description 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 1G 1A1 1A2 1A3 1A4 VCC VCC 2A1 2A2 2A3 2A4 2G 54AC11241 . . . FK PACKAGE (TOP VIEW) 1A2 1A1 1G NC 1Y1 1Y2 1Y3 The 54AC11241 is characterized for operation over the full military temperature range of – 55°C to 125°C. The 74AC11241 is characterized for operation from – 40°C to 85°C. NC – No internal connection 1A3 1A4 VCC NC VCC 2A1 2A2 This octal buffer or line driver is designed specifically to improve both the performance and density of three-state memory address drivers, clock drivers, and bus-oriented receivers and transmitters. Taken together with the AC11240 and AC11244, these devices provide the choice of selected combinations of inverting and noninverting outputs, symmetrical G (activelow output control) inputs, and complementary G and G inputs. This device features a high fan-out. 4 5 3 2 1 28 27 26 25 6 24 7 23 8 22 9 21 10 20 1Y4 GND GND NC GND GND 2Y1 11 19 12 13 14 15 16 17 18 2A3 2A4 2G NC 2Y4 2Y3 2Y2 FUNCTION TABLE OUTPUT CONTROL 1G DATA INPUT 1A OUTPUT 1Y H X L L L H OUTPUT CONTROL 2G DATA INPUT 2A OUTPUT 2Y Z L X Z L H L L H H H H EPIC is a trademark of Texas Instruments Incorporated. Copyright 1993, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–1 54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 logic symbol† 1G 1A1 1A2 1A3 1A4 2G 2A1 2A2 2A3 2A4 24 logic diagram (positive logic) EN 1G 23 1 22 2 21 3 20 4 13 1Y1 1A1 24 23 1 22 2 21 3 20 4 1Y1 1Y2 1Y3 1A2 1Y2 1Y4 1A3 1Y3 EN 17 9 16 10 15 11 14 12 1A4 1Y4 2Y1 2Y2 2G 13 2Y3 2Y4 † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. 2A1 17 2A2 16 2A3 2A4 9 2Y1 10 2Y2 15 11 14 12 2Y3 2Y4 Pin numbers shown are for the DW, JT, and NT packages. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 200 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2–2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 recommended operating conditions 54AC11241 VCC Supply voltage VIH High-level input voltage VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V MIN NOM MAX 3 5 5.5 0 TA Operating free-air temperature 5.5 3.85 Output voltage Input transition rise or fall rate 5 3.15 0 Dt /Dv 3 3.85 Input voltage Low-level output current MAX 3.15 VI VO IOL NOM 2.1 Low-level input voltage High-level output current MIN 2.1 VIL IOH 74AC11241 VCC = 4.5 V VCC = 5.5 V V V 0.9 9.9 1.35 1.35 1.65 V 1.65 VCC VCC VCC = 3 V VCC = 4.5 V UNIT 0 VCC VCC 0 –4 –4 – 24 – 24 VCC = 5.5 V VCC = 3 V – 24 – 24 12 12 VCC = 4.5 V VCC = 5.5 V 24 24 24 24 Data 0 10 0 10 G 0 5 0 5 – 55 125 – 40 85 V V mA mA ns/ V °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = – 50 mA VOH IOH = – 4 mA IOH = – 24 mA IOH = – 50 mA{ IOH = – 75 mA{ IOL = 50 mA VOL IOL = 12 mA IOL = 24 mA IOL = 50 mA{ IOL = 75 mA{ VCC MIN TA = 25°C TYP MAX 54AC11241 MIN MAX 74AC11241 MIN 3V 2.9 2.9 2.9 4.5 V 4.4 4.7 4.4 5.5 V 5.4 5.4 5.4 3V 2.58 2.4 2.48 4.5 V 3.94 3.7 3.8 5.5 V 4.94 4.7 4.8 5.5 V MAX V 3.85 5.5 V 3.85 3V 0.1 0.1 0.1 4.5 V 0.1 0.1 0.1 5.5 V 0.1 0.1 0.1 3V 0.36 0.5 0.44 4.5 V 0.36 0.5 0.44 5.5 V 0.36 0.5 0.44 5.5 V 1.65 IOZ II VO = VCC or GND VI = VCC or GND 5.5 V ± 0.5 5.5 V ICC Ci VI = VCC or GND, IO = 0 VI = VCC or GND 5.5 V ± 10 ±5 ± 0.1 ±1 ±1 8 160 80 4 Co VO = VCC or GND 5V 10 † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. POST OFFICE BOX 655303 V 1.65 5.5 V 5V UNIT • DALLAS, TEXAS 75265 mA mA mA pF pF 2–3 54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 switching characteristics over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Y tPZH tPZL G or G Y tPHZ tPLZ G or G Y MIN TA = 25°C TYP MAX 1.5 7 1.5 54AC11241 74AC11241 MIN MAX MIN MAX 10 1.5 12.2 1.5 11.4 6.2 8.4 1.5 10.2 1.5 9.2 1.5 7.8 11.4 1.5 13.8 1.5 12.9 1.5 7.7 10.6 1.5 12.6 1.5 11.7 1.5 5.8 7.6 1.5 8.2 1.5 7.9 1.5 7.1 9.3 1.5 10.3 1.5 9.9 UNIT ns ns ns switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Y tPZH tPZL G or G Y tPHZ tPLZ G or G Y TA = 25°C MIN TYP MAX 54AC11241 74AC11241 MIN MAX MIN MAX 1.5 4.9 7.1 1.5 8.5 1.5 8 1.5 4.5 6.3 1.5 7.2 1.5 6.8 1.5 5.4 8 1.5 9.7 1.5 9 1.5 5.3 7.6 1.5 9 1.5 8.4 1.5 4.9 6.6 1.5 7.2 1.5 6.9 1.5 5.6 7.5 1.5 8.3 1.5 8 UNIT ns ns ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd d 2–4 Power dissipation capacitance per buffer TEST CONDITIONS Outputs enabled Outputs disabled POST OFFICE BOX 655303 CL = 50 pF, pF • DALLAS, TEXAS 75265 f = 1 MHz TYP 26 10 UNIT pF 54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 PARAMETER MEASUREMENT INFORMATION 2 × VCC S1 500 Ω From Output Under Test Open GND LOAD CIRCUIT Output Control (low-level enabling) VCC 50% 50% 0V tPLH tPHL VOH Output S1 Open 2 × VCC GND 50% 50% 500 Ω CL = 50 pF (see Note A) Input (see Note B) TEST tPLH/tPHL tPLZ/tPZL tPHZ/tPZH 50% VCC 50% VCC VOL VCC 0V tPZL Output Waveform 2 S1 at GND (see Note C) [ VCC tPLZ Output Waveform 1 S1 at 2 × VCC (see Note C) 50% VCC VOL tPHZ tPZH VOLTAGE WAVEFORMS 20% VCC 50% VCC 80% VCC VOH [0V VOLTAGE WAVEFORMS NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. D. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–5 54AC11241, 74AC11241 OCTAL BUFFERS/LINE DRIVERS WITH 3-STATE OUTPUTS SCAS032A – JULY 1987 – REVISED APRIL 1993 2–6 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated