FERROXCUBE 3S4

FERROXCUBE
DATA SHEET
3S4
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3S4
3S4 SPECIFICATIONS
Wideband EMI-suppression material specified on
impedance and optimized for frequencies from 10 to
300 MHz.
SYMBOL
µi
B
Z(1)
ρ
TC
density
CONDITIONS
25 °C; ≤10 kHz;
0.25 mT
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
25 °C; 3 MHz
25 °C; 30 MHz
25 °C; 100 MHz
25 °C; 300 MHz
DC; 25 °C
VALUE
≈ 1 700
10 3
µ's
µ''s
mT
≈ 170
10 2
≥ 25
≥ 60
≥ 80
≥ 90
≈ 103
≥ 110
≈ 4 800
Ω
10
10 1
Fig.1
1. Measured on a bead ∅5× ∅2 × 10 mm.
10
f (MHz)
10 2
Complex permeability as
a function of frequency.
MBW199
MBW191
5000
1
Ωm
°C
kg/m3
Note
handbook, halfpage
3S4
µ's , µ''s
UNIT
≈ 320
MBW195
10 4
handbook, halfpage
500
25oC
100oC
handbook, halfpage
3S4
B
(mT)
µi
4000
400
3000
300
2000
200
1000
100
3S4
0
0
50
50
Fig.2
2008 Sep 01
150
T (oC)
50
250
Initial permeability as a
function of temperature.
0
50
100
500
1000
H (A/m)
Fig.3 Typical B-H loops.
212
Ferroxcube
Material specification
3S4
MBW221
150
handbook, halfpage
3S4
Z
(Ω)
100
50
0
1
10
102
f (MHz)
103
Fig.4 Impedance as a function of frequency
measured on a bead ∅5 × ∅2 × 10 mm.
2008 Sep 01
213
Ferroxcube
Material specification
3S4
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
214