FERROXCUBE 3E6

FERROXCUBE
DATA SHEET
3E6
Material specification
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Material specification
3E6
3E6 SPECIFICATIONS
A high permeability material optimized for use in
wideband transformers as well as EMI-suppression
filters.
µi
B
tanδ/µi
ηB
ρ
TC
density
CONDITIONS
VALUE(1)
25 °C; ≤10 kHz;
0.25 mT
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
25 °C; 10 kHz; 0.25 mT
25 °C; 30 kHz; 0.25 mT
25 °C; 10 kHz;
1.5 to 3 mT
DC; 25 °C
12000 ± 20%
≈ 390
µ's
10 4
mT
µ''s
10 3
≤ 10 × 10−6
≤ 30 × 10−6
≤ 1 × 10−3
T−1
≈ 0.1
≥ 130
≈ 4900
Ωm
°C
kg/m3
2
10
10 2
Note
1
f (MHz)
10
Complex permeability as
a function of frequency.
MBW266
MBW265
500
25 oC
100 oC
handbook, halfpage
3E6
µi
10 1
Fig.1
1. Measured on sintered, non-ground ring cores of
dimensions Ø14 × Ø9 × 5 which are not subjected to
external stresses.
40000
3E6
µ's , µ''s
UNIT
≈ 220
handbook, halfpage
MBW264
10 5
handbook, halfpage
B
(mT)
3E6
400
30000
300
20000
200
10000
100
0
50
0
50
Fig.2
2008 Sep 01
150
T ( o C)
250
25
0
25
50
150
250
H (A/m)
Initial permeability as a
function of temperature.
Fig.3 Typical B-H loops.
161
Ferroxcube
Material specification
3E6
MBW267
10 5
handbook, halfpage
3E6
µ rev
10 4
10 3
10
2
1
Fig.4
2008 Sep 01
10
10 2
3
H (A/m) 10
Reversible permeability as a
function of magnetic field strength.
162
Ferroxcube
Material specification
3E6
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
163