GAMEWELL-FCI SS-APT

SS-APT
Features
• Automatically adjusts sensitivity levels
without the need for operator intervention or programming. Sensitivity
increases with heat.
Acclimate™ Multi-Sensor Smoke Detector
Low-Profile, Intelligent, Addressable
• Microprocessor-based, combination
photo and thermal technology.
• Addressable-analog communication.
Description
• Sleek, low-profile design.
Gamewell’s SS-APT Acclimate™ detector is an intelligent,
addressable, multi-sensing, lowprofile detector designed for use
with any 600 series SmartScanTM
SLC panel.
6937pho1.jpg
The Acclimate™ detector uses a
combination of photoelectric and
SS-APT in SS-B6 base
thermal sensing technologies
that are designed to increase immunity to false alarms. Unlike
traditional intelligent detectors,
the Acclimate™ detector has a microprocessor in the detector head that processes
alarm data. As a result, the Acclimate™ detector adjusts its sensitivity automatically,
without operator intervention or control panel programming.
Areas where the Acclimate™ detector is especially useful include office complexes,
schools, college campuses, manufacturing and industrial facilities, and anywhere
else the use of a particular area may change. The Acclimate™ detector automatically
adjusts its sensitivity to acclimate itself to the environment.
Installation
• Sleek, low-profile design.
• Rotary, decimal addressing (1 – 99).
• Addresses can be viewed and
changed without the need for electronic programmers.
• Dual bi-color LED design provides
360° viewing angle.
• Built-in tamper-resistant feature.
• Sealed against back pressure.
• Constructed of off-white Bayblend®,
designed to commercial standards,
and offers an attractive appearance.
• 94-5V plastic flammability rating.
• SEMS screws for wiring of the
separate base.
• Several base options, including relay,
isolator, and sounder.
• Remote test feature from the panel.
The SS-APT plug-in detector uses a separate base to simplify installation, service,
and maintenance. A special tool allows maintenance personnel to plug-in and remove detectors without using a ladder. Mount base on an electrical backbox at least
1.5" (3.81 cm) deep. Suitable mounting back boxes include:
• 4.0" (10.16 cm) square box.
• 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
• Built-in functional test switch activated by external magnet.
• Capable of heat-only alarm mode,
enabled by a special command from
the panel. Smoke alarms are ignored.
• Low-temperature signal at 45°F +/–
10°F (7.22°C +/– 5.54°C).
• Single-gang box (except for relay or isolator base).
• With B501BH or B501BHT base, use a 4.0" (10.16 cm) square box.
• With B224RB or B224BI base, use a 3.5" (8.89 cm) octagonal box, or a 4.0"
(10.16 cm) octagonal or square box.
NOTES: 1) Because of the inherent supervision provided by the SLC loop, endof-line resistors are not required. Wiring “T-taps” or branches are permitted for
Style 4 (Class “B”) wiring. 2) When using relay or sounder bases, consult SS-LI
data sheet for device limitations between isolator modules and isolator bases.
APPLICATION NOTE: The SS-APT detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing
these detectors in locations that are susceptible to rapid and high temperature
changes. An example of an incorrect application would be near or in line with the
output of a self-contained heater.
DETECTOR SPACING: Gamewell recommends spacing detectors in compliance with
NFPA 72. In low airflow applications with smooth ceilings, space detectors 30 feet
(9.144 m). For specific information regarding detector spacing, placement, and special applications, refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com.
Acclimate™ is a trademark of System Sensor.
Bayblend® is a registered trademark of Bayer Corporation.
SS-APT CS-2462 09/01/06
• Two-wire SLC connection.
Page 1 of 2
Listings
Listings and approvals below apply to
the SS-APT AcclimateTM Multi-Sensor
Low-Profile Intelligent Addressable
Smoke detectors. In some cases,
certain detectors may not be listed by
certain approval agencies, or listing
may be in process. Consult factory for
latest listing status.
• UL Listed: file S1195.
• CSFM approved: file 7272-1288:165.
• MEA approved: file 275-02-E Vol. IV.
Product Line Information
Specifications
SS-APT: Low-profile intelligent multi- XR2B: Detector removal tool. Allows insmoke detector. Must be mounted to one stallation and/or removal of the SS-APT
Series detector heads from base in high
of the bases listed below.
ceiling installations.
Bases:
SS-B6: Standard U.S. low-profile base, UL T55-127-000: Detector removal tool without pole.
Listing.
B501BP: Standard European flangeless XP-4: Extension pole for XR2B. Comes
in three 5-ft. sections.
base, pkg. of 10.
Sensitivity
Auto-adjusting levels
1 to 2, 2 to 3, and 3 to 4%/ft.
Fixed-sensitivity levels: 0.5, 1, 2, 3, and
4%/ft.
Size
2.1" (5.3 cm) high x 4.1" (10.4 cm)
diameter installed in B501 base, 6.1"
(15.5 cm) diameter installed in SS-B6
base.
Shipping weight
5.2 oz. (147 g).
Operating temperature
0°C to 38°C (32°F to 100°F).
UL-Listed velocity range
0 – 4000 ft./min. (1219.2 m/min.), suitable
for installation in ducts.
Relative humidity
10% – 93% noncondensing.
Thermal sensing rating
Fixed-temperature setpoint 135°F (57°C).
B501BH: Sounder base, includes B501
base above.
B501BHT: Same as B501BH, but includes
temporal sounder.
B224RB: Intelligent relay base.
B224BI: Intelligent isolator base. Isolates
SLC from loop shorts.
Accessories:
RA400Z: Remote LED annunciator. 3 – 32
VDC. Fits U.S. single-gang electrical box.
Supported by SS-B6 and B501 bases only.
SMK400: Surface mounting kit provides for
entry of surface wiring conduit. For use with
B501 base only.
RMK400: Recessed mounting kit. For use
with B501 base only.
SMB600: Surface mounting kit for use with
SS-B6.
BCK-200B: Black detector covers, box of 10.
M02-04-01: Test magnet.
M02-09-00: Test magnet with telescope
stick.
Detector Guards:
NOTE: The following guards are not UL
listed with the SS-APT. Consult with local AHJ.
STI 9601: Low-profile, flush-mount smoke
detector guard, wire.
STI 9602: Low-profile, surface-mount,
smoke detector guard, wire.
STI 9609: High-profile, flush-mount, smoke
detector guard, wire.
STI 9605: High-profile, surface-mount,
smoke detector guard, wire.
STI 9604: Flush-mount heat detector
guard, wire.
STI 9610: Surface-mount heat detector
guard, wire.
STI-8200-SS: Flush-mount stainless
steel smoke detector guard.
STI-8230-SS: Surface-mount stainless
steel smoke detector guard.
Wiring Diagrams
ELECTRICAL SPECIFICATIONS:
Voltage range
15 – 32 volts DC peak.
Standby current (max. avg.)
250 µA @ 24 VDC (without communication); 360 µA @ 24 VDC (one communication every 5 seconds with LED enabled).
Loop resistance
40 ohms maximum; varies according to
control panel used. Refer to panel
installation manuals.
LED current (max.)
6.5 mA @ 24 VDC (“ON”).
BASES AVAILABLE:
SS-B6: 6.1" (15.5 cm) diameter.
B501: 4.1" (10.4 cm) diameter.
B501BH or B501BHT: Sounder base
assembly. Includes B501 base.
4762wir1.tif
B224RB Relay Base: Screw terminals:
up to 14 AWG (2.0 mm²). Relay type:
Form-C. Rating: 2.0 A @ 30 VDC
resistive; 0.3 A @ 110 VDC inductive; 1.0
A @ 30 VDC inductive. Dimensions: 6.2"
(15.748 cm) x 1.2" (3.048 cm).
B224BI Isolator Base: Dimensions: 6.2"
(15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases.
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610
Phone: 203-484-7161
Fax: 203-484-7118
www.gamewell-fci.com
A Honeywell Company
© 2006 Gamewell-FCI
Address dial on back of detector.
Specifications and wiring information are provided for information only and are believed
to be accurate. Gamewell-FCI assumes no responsibility for their use.
Data and design are subject to change without notice. Installation and wiring instructions
shipped with the product shall always be used for actual installation. For more
information, contact Gamewell-FCI.
Page 2 of 2
SS-APT
CS-2462
09/01/06