Intelligent Bases Description B501, B224RB, B224BI, and B210LP, Mounting Kits, and Accessories The Intelligent Velociti® and CLIP™ mounting bases and kits provide a variety of ways to install Gamewell-FCI detectors in any application. These mounting bases are non-addressable and are available in both the Velociti and Clip protocols. The intelligent detectors can be mounted in any of the following, depending on the junction box selection (see Table 1 - Junction Box Selection Guide). • flanged bases • flangeless bases • plastic rings Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for the control of auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in a combination temporal 3 and continuous tone model. The Intelligent Bases provide a variety of mounting options to meet your installation challenges. The bases come in flanged or flangeless versions so that you can mount the bases to a variety of junction boxes. See Table 1 for the Junction Box Selection Guide. You can use the SMB600 surface mounting box to mount the following bases: • B224RB relay base • B210LP relay base • B224BI isolator base System Temperature and Humidity Ranges: These bases comply with the NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC®. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that the bases and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Figure 2 B210LP Mounting Base Figure 3 B224BI Mounting Base Figure 4 B224RB Mounting Base Features All sounder bases offer the following features. • Complies with UL Standards 268 and 464. • Includes the following three types of bases that comply with local code requirements: - Relay - Isolator - Sounder • Offers temporal and non-temporal pattern versions. Relay Base Feature • Relay bases provide one Form-C contact relay. Isolator Base Feature • Specifications Figure 1 B501 Mounting Base Isolator bases include data communications lines to operate under fault condition. Installation Features The bases offer the following flexible installation characteristics. • Has multiple accessory options. • Includes an installation mounting kit and accessories for several types of model options. • Supports 12-24 AWG gauge wire ranges to provide the bases with flexible installation. • Contains bases that enable quick and secure detector plug-in. • Provides SEMS screws for easy wiring connections. SIGNALING ® Velociti is a registered trademark & Clip™ is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ULC® is a registered trademark of Underwriters Laboratories of Canada Inc. FM APPROVED S911 3035027 7135-1653:0213 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60540 Rev. F page 1 of 2 ©2014 Honeywell International Inc. All rights reserved. Temperature Range: For B501, B224RB, B224BI, and B210LP 32°F to 120°F (0°C to 49° C) Humidity Range: 10% to 93% RH, non-condensing Wire Gauge: For B224BI, B224RB: 14 to 24 AWG Electrical Ratings For B224RB, B224BI: Operating Voltage: 15 to 32 VDC (powered by SLC) Standby Ratings: <500 µA maximum @ 24 VDC Set Time (B224RB only): Short delay: 55-90 mseconds Long delay: 6 to 9 seconds Reset Time (B224RB only): 20 mseconds maximum Relay Characteristics (B224RB only): Two-coil Latching Relay One Form-C Contact Ratings (UL/CSA): 0.9 A @ 125 VAC (inductive) 0.9 A @ 110 VDC (inductive) 3.0 A @ 30 VDC (resistive) Ordering Information Intelligent Bases Part Number B501 Dimensions: B501BP Dimensions: B224BI Dimensions: B224RB Dimensions: B210LP Dimensions: B210LPBP Dimensions: XR2B XP-4 T55-127-000 BCK-200B WCK-200B Description Flangeless mounting base 4.1” (10.41 cm) diameter Flangeless mounting base bulk pack 4.1” (10.41 cm) diameter Isolator base 6.875” (17.462 cm) diameter Relay base 6.875” (17.462 cm) diameter Flanged mounting base 6.1” (15.5 cm) diameter Flanged mounting base bulk pack 6.1” (15.5 cm) diameter Detector removal tool (T55-127-000 included). Extension pole for XR2B (5 to 15 ft/1.524 to 4.572 m) Detector removal head. Black detector kit. White detector kit. Mounting Kits and Accessories Part Number SMB600 F110 F110BP F210 M02-04-01 M02-09-00 Description Surface mounting kit, flanged. Accessory retrofit flange ring for B210LP Accessory retrofit flange ring for the B210LPBP bulk pack of 15. Accessory with a new smaller flange ring for the B210LP. Detector test magnet. Test magnet with telescoping handle. Table 1 shows the Junction Box Selection Guide. Table 1: Junction Box Selection Guide 3.5" 4.0" 4.0" 4.0" Square with Single-Gang Octagonal Octagonal Square 3.0" mud ring 50 mm 60 mm 70 mm B501 No Yes No No Yes Yes Yes Yes B210LP Yes Yes Yes Yes Yes No No No B224BI No Yes Yes Yes Yes No Yes Yes B224RB No Yes Yes Yes Yes No Yes Yes NOTE: The box depth is contingent on the base and the wire size. For information on applicable local codes for appropriate recommendation, refer to the National Electrical Code. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60540 Rev. F page 2 of 2 www.gamewell-fci.com 75 mm No No Yes Yes