TI 74AC11238

54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
•
•
•
•
•
•
•
Designed Specifically for High-Speed
Memory Decoders and Data Transmission
Systems
Noninverting Version of ′AC11138
Incorporates 3 Enable Inputs to Simplify
Cascading and/or Data Reception
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPIC (Enhanced-Performance Implanted
CMOS) 1-mm Process
500-mA Typical Latch-Up Immunity
at 125°C
Package Options Include Plastic
Small-Outline Packages, Ceramic Chip
Carriers, and Standard Plastic and Ceramic
300-mil DIPs
54AC11238 . . . J PACKAGE
74AC11238 . . . D OR N PACKAGE
(TOP VIEW)
Y1
Y2
Y3
GND
Y4
Y5
Y6
Y7
t
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
Y0
A
B
C
VCC
G1
G2A
G2B
54AC11238 . . . FK PACKAGE
(TOP VIEW)
A
Y0
NC
Y1
Y2
description
1
B
C
NC
VCC
G1
•
4
3 2 1 20 19
18
5
17
6
16
G2A
G2B
NC
Y7
Y6
Y3
GND
NC
Y4
Y5
The ′AC11238 circuit is designed to be
15
7
used in high-performance memory-decoding or
14
8
data-routing applications requiring very short
9 10 11 12 13
propagation delay times. In high-performance
memory systems, this decoder can be used to
minimize the effects of system decoding. When
employed with high-speed memories utilizing a
NC – No internal connection
fast enable circuit, the delay times of this decoder
and the enable time of the memory are usually less than the typical access time of the memory. This means that
the effective system delay introduced by the decoder is negligible.
The conditions at the binary select inputs and the three enable inputs select one of eight input lines. Two
active-low and one active-high enable inputs reduce the need for external gates or inverters when expanding.
A 24-line decoder can be implemented without external inverters and a 32-line decoder requires only one
inverter. An enable input can be used as a data input for demultiplexing applications.
The 54AC11238 is characterized for operation over the full military temperature range of – 55°C to 125°C. The
74AC11238 is characterized for operation from – 40°C to 85°C.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1993, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily
include testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–1
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
FUNCTION TABLE
SELECT
INPUTS
ENABLE
INPUTS
OUTPUTS
G1
G2A
G2B
C
B
A
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
X
H
X
X
X
X
L
L
L
L
L
L
L
L
X
X
H
X
X
X
L
L
L
L
L
L
L
L
L
X
X
X
X
X
L
L
L
L
L
L
L
L
H
L
L
L
L
L
H
L
L
L
L
L
L
L
H
L
L
L
L
H
L
H
L
L
L
L
L
L
H
L
L
L
H
L
L
L
H
L
L
L
L
L
H
L
L
L
H
H
L
L
L
H
L
L
L
L
H
L
L
H
L
L
L
L
L
L
H
L
L
L
H
L
L
H
L
H
L
L
L
L
L
H
L
L
H
L
L
H
H
L
L
L
L
L
L
L
H
L
H
L
L
H
H
H
L
L
L
L
L
L
L
H
logic symbols (alternatives)†
A
B
C
15
14
13
BIN/OCT
0
1
2
1
4
2
3
G1
G2A
G3A
11
10
9
&
4
5
EN
6
7
16
1
2
3
5
6
7
8
Y0
Y1
Y2
A
B
C
15
0
0
G
7
14
13
2
3
&
Y4
Y5
Y6
Y7
POST OFFICE BOX 655303
1
2
Y3
G1
G2A
G2B
4
11
10
9
† These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2–2
DMUX
0
• DALLAS, TEXAS 75265
5
EN
6
7
16
1
2
3
5
6
7
8
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
logic diagram (positive logic)
16
A
1
B
C
14
2
3
13
5
6
G1
G3A
Y1
Y2
Y3
Y4
Y5
11
7
G2A
Y0
15
Y6
10
8
Y7
9
Pin numbers shown are for the D, J, and N packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 200 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–3
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
recommended operating conditions
54AC11238
VCC
Supply voltage
VIH
VCC = 3 V
VCC = 4.5 V
High-level input voltage
VCC = 5.5 V
VCC = 3 V
VIL
Low-level input voltage
VI
VO
MAX
3
5
5.5
Input transition rise or fall rate
TA
Operating free-air temperature
3
5
5.5
3.15
UNIT
V
V
3.85
0.9
0.9
1.35
1.35
1.65
1.65
VCC
VCC
0
Dt /Dv
MAX
3.15
VCC = 3 V
VCC = 4.5 V
Low-level output current
NOM
2.1
0
High-level output current
MIN
2.1
VCC = 4.5 V
VCC = 5.5 V
Output voltage
IOL
NOM
3.85
Input voltage
IOH
74AC11238
MIN
0
VCC
VCC
0
–4
–4
– 24
– 24
VCC = 5.5 V
VCC = 3 V
– 24
– 24
12
12
VCC = 4.5 V
VCC = 5.5 V
24
24
24
24
V
V
V
mA
mA
0
10
0
10
ns/ V
– 55
125
– 40
85
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
IOH = – 50 mA
VOH
IOH = – 4 mA
IOH = – 24 mA
IOH = – 50 mA}
IOH = – 75 mA}
IOL = 50 mA
VOL
IOL = 12 mA
IOL = 24 mA
IOL = 50 mA}
IOL = 75 mA}
VCC
MIN
TA = 25°C
TYP†
MAX
54AC11238
MIN
MAX
74AC11238
MIN
3V
2.9
2.9
2.9
4.5 V
4.4
4.4
4.4
5.5 V
5.4
5.4
5.4
3V
2.58
2.4
2.48
4.5 V
3.94
3.7
3.8
5.5 V
4.94
4.7
4.8
5.5 V
MAX
V
3.85
5.5 V
3.85
3V
0.1
0.1
0.1
4.5 V
0.1
0.1
0.1
5.5 V
0.1
0.1
0.1
3V
0.36
0.5
0.44
4.5 V
0.36
0.5
0.44
5.5 V
0.36
0.5
0.44
5.5 V
5.5 V
1.65
±1
IO = 0
5.5 V
4
80
VI = VCC or GND
5V
3.5
† All typical values are at VCC = 5 V, TA = 25°C.
‡ Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
40
VI = VCC or GND
VI = VCC or GND,
5.5 V
± 0.1
Ci
2–4
POST OFFICE BOX 655303
V
1.65
±1
II
ICC
UNIT
• DALLAS, TEXAS 75265
mA
mA
pF
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A B
A,
B, C
Any Y
tPLH
tPHL
G1
Any Y
tPLH
tPHL
G2A G2B
G2A,
Any Y
MIN
TA = 25°C
TYP
MAX
54AC11238
74AC11238
MIN
MAX
MIN
MAX
1.5
8.5
10.6
1.5
12.7
1.5
11.7
1.5
9.6
11.9
1.5
14.3
1.5
13.3
1.5
8.2
10.3
1.5
12.3
1.5
11.4
1.5
9.6
11.7
1.5
14
1.5
13
1.5
9.1
11.2
1.5
13.4
1.5
12.5
1.5
10.7
12.9
1.5
15.6
1.5
14.5
UNIT
ns
ns
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A B
A,
B, C
Any Y
tPLH
tPHL
G1
Any Y
tPLH
tPHL
G2A G2B
G2A,
Any Y
MIN
TA = 25°C
TYP
MAX
54AC11238
MIN
74AC11238
MAX
MIN
MAX
1.5
5.4
7.3
1.5
9
1.5
8.5
1.5
6.3
8.6
1.5
10.9
1.5
10.2
1.5
5.2
6.9
1.5
8.7
1.5
8.1
1.5
6.5
8.5
1.5
10.6
1.5
9.9
1.5
5.6
7.5
1.5
9.6
1.5
8.9
1.5
7.2
9.3
2.5
11.8
1.5
11
UNIT
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
TEST CONDITIONS
Power dissipation capacitance
CL = 50 pF,
f = 1 MHz
TYP
UNIT
44
pF
PARAMETER MEASUREMENT INFORMATION
VCC
Input
(see Note B)
From Output
Under Test
CL = 50 pF
(see Note A)
50%
50%
0V
tPHL
500 Ω
tPLH
50% VCC
Output
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–5
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
TYPICAL APPLICATION DATA
74AC11238
BIN/OCT
15
14
13
VCC
0
1
1
2
2
4
11
3
&
4
10
EN
9
5
6
7
16
1
2
3
5
6
7
8
0
1
2
3
4
5
6
7
74AC11238
BIN/OCT
15
A0
14
A1
13
A2
1
2
2
4
11
A3
0
1
3
&
4
10
A4
EN
9
5
6
7
16
1
2
3
5
6
7
8
8
9
10
11
12
13
14
15
74AC11238
BIN/OCT
15
14
13
11
0
1
1
2
2
4
3
&
4
10
9
EN
5
6
7
Pin numbers shown are for the D, J, and N packages.
Figure 2. 24-Bit Decoding Scheme
2–6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
16
1
2
3
5
6
7
8
16
17
18
19
20
21
22
23
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
TYPICAL APPLICATION DATA
74AC11238
BIN/OCT
15
A0
14
A1
13
A2
1
1
2
2
4
11
VCC
0
3
&
4
10
A3
EN
9
A4
5
6
7
16
1
2
3
5
6
7
8
0
1
2
3
4
5
6
7
74AC11238
BIN/OCT
15
14
13
0
1
1
2
2
4
11
3
&
4
10
EN
9
5
6
7
16
1
2
3
5
6
7
8
8
9
10
11
12
13
14
15
74AC11238
BIN/OCT
15
14
13
0
1
1
2
2
4
11
3
&
4
10
EN
9
5
6
7
16
1
2
3
5
6
7
8
16
17
18
19
20
21
22
23
74AC11238
BIN/OCT
15
14
13
11
0
1
1
2
2
4
3
&
4
10
9
EN
5
6
7
16
1
2
3
5
6
7
8
24
25
26
27
28
29
30
31
Pin numbers shown are for the D, J, and N packages.
Figure 3. 32-Bit Decoding Scheme
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–7
54AC11238, 74AC11238
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS039A – APRIL 1988 – REVISED APRIL 1993
2–8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated