HITRON HAS10

H HiTRON
2008/03/31
CHASSIS-MOUNT UNIVERSAL INPUT AC-DC GREEN POWER
ENCAPSULATED MODULAR POWER SUPPLIES 10 WATTS
MULTIPLE OUTPUT HAS10G-S &HAS10-D/T SERIES
FEATURES:
„
CHASSIS-MOUNT AC/DC MODULAR
POWER SUPPLIES
„
UNIVERSAL AC INPUT RANGE
„
GREEN POWER DESIGN
„
MEET UNIVERSAL SAFETY STANDARDS
„
EMI MEETS CISPR PUB.22/FCC CLASS B
„
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Frequency: 47-63 Hz. (Nominal 50/60Hz.).
Input Current: 0.16A @115Vac./0.1A @230Vac typical.
Inrush Current: 4.2Arms@230Vac typical.
Input Fuse: Use external fuse.
Dielectric Withstand: Meet IEC60950-1.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB. 22/FCC Class B.
Hold-up time: Typ. 22.4 mS @115Vac, 130mS @230Vac.
Green Power: 0.25W@132Vac, 0.51W@230Vac for single.
Earth Leakage: Less than 0.16mA @230Vac.
Remote ON/OFF:
ON(Enable)=Open.
OFF(Disable)=Short.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 10 Watts typical.
Line Regulation: Various with output voltage. Typ.±0.1% .
Load Regulation: Various with output voltage.
Main VO1 ± 0.1-2.0% typical.
Aux.VO2 ± 0.7-1.2% typical.
Aux.VO3 ± 0.1% typical.
Total Regulation: 0.1-1.9% typical.
Noise & ripple: 1.0% typical peak to peak.
Typ. 100mV for 3.3V/5v.
OVP: Built-in on main output VO1.
Adjustability: Available at main output VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
Typical 125-150% of rating output load.
Con2sult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 70-80% typical various with output voltage.
Switching Frequency: 80K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Peak deviation on 70mV,
Recovery time <0.2mSec.@ 25%step load change.
Case: Impact resistant thermo-plastic enclosure.
Safety Standard: EN60950-1/ UL60950-1 Class I.
Power Density: 1.22 Watts. / Cubic inch.
Operating Temperature: 0°C to +50°C range. @ full load
without derating.
From+50°C derating linearly to half load @+70°C
(Refer to the Derating Chart).
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ±0.03% /°C.
Cooling: Convection cooling for +50°C @ full load.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
(3) Due to requests in market and advances in technology, specifications subject to change without notice.
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
DUAL OUTPUT
SINGLE OUTPUT
MODEL NO.
HAS10G-S033250
HAS10G-S050200
HAS10G-S090111
HAS10G-S120085
HAS10G-S150067
HAS10G-S240041
VO1
TYP.
2.50A
2.00A
1.11A
0.85A
0.67A
0.41A
★@
VOLT.
+3.3V
+5.0V
+9.0V
+12.0V
+15.0V
+24.0V
VO1 ★@
TYP.
VOLT.
1.00A
+5V
1.00A
+5V
0.42A
+12V
0.34A
+15V
1.51A
+3.3V
MODEL NO.
HAS10-D050E
HAS10-D050I
HAS10-D120I
HAS10-D150K
HAS10-D033E
TYP
1.00A
0.42A
0.42A
0.34A
1.00A
VO2●
VOLT.
-5V
+12V
-12V
-15V
-5V
TRIPLE OUTPUT
MODEL NO.
HAS10-T033II
HAS10-T050II
HAS10-T050KK
VO1 @ ★
VO2 ●
TYP.
TYP.
VOLT.
VOLT.
1.51A
0.10A
+3.3V
+12V
1.50A
0.10A
+5.0V
+12V
1.40A
0.10A
+5.0V
+15V
"@" Adjustable. "●" Installed with Post Regulator (P.R.).
VO3 ●
TYP.
VOLT.
0.10A
-12V
0.10A
-12V
0.10A
-15V
Symbols: "★" OVP built-in.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 177.5g (6.26 Oz.)
PIN ASSIGNMENT
PIN
NO.
P1-1
P1-3
P1-2
P2-2
P2-3
SINGLE
O/P
L
N
G
REMOTE
ON/OFF
DC COM
DC COM
DUAL
O/P(-VO2)
L
N
G
REMOTE
ON/OFF
VO2
DC COM
P2-4
VO1
DC COM
VO1
+VO3
P2-5
VO1
VO1
VO2
DC COM
P2-6
NC
NC
NC
VO2
P2-1
DERATING CHART
DUAL
O/P(+VO2)
L
N
G
REMOTE
ON/OFF
DC COM
DC COM
TRIPLE
O/P
L
N
G
REMOTE
ON/OFF
+VO1RET
+VO1