Specifications Link - Total Power International

Total Power International, Inc.
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 5 WATTS SINGLE & DUAL OUTPUT
TPAM05S & TPAM05D SERIES
FEATURES:
ON-BOARD AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Frequency: 47-63 Hz. (50/60Hz.Nom.).
Input Current: 0.15A @115Vac./0.07A @230Vac.
Inrush Current: 32.5A peak @ 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 20 mS @115Vac, 80mS @230Vac.
Earth Leakage: Less than 3.5mA @230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart
Output Wattage: 5Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltages.
TPAM05S ±0.1 % typical.
TPAM05D ±0.5% typical.
Load Regulation: Various with output voltage.
TPAM05S ±1.0% typical.
TPAM05D ±2.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 64%-78% typical. (Various with output voltage).
Switching Frequency: 75K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Weight: 107.0g (3.77 Oz).
Power Density: 1.61 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25°C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.03% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load > +50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
Due to requests in market and advances in technology, specifications subject to change without notice.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
DUAL OUTPUT
VO1 @ ★
TYP.
VOLT. PEAK
MODEL NO.
+VO1 @ ★
TYP.
VOLT.
MAX.
-VO2 ║
TYP. VOLT. MAX.
TPAM05S-033130
1.30A
3.3V
1.59A
TPAM05D-033064
0.64A
+3.3V
0.73A
0.64A
-3.3V
0.73A
TPAM05S-050100
1.00A
5.0V
1.20A
TPAM05D-050050
0.50A
+5.0V
0.57A
0.50A
-5.0V
0.57A
TPAM05S-090060
0.60A
9.0V
0.72A
TPAM05D-090030
0.30A
+9.0V
0.34A
0.30A
-9.0V
0.34A
TPAM05S-120045
0.45A
12.0V
0.54A
TPAM05D-120022
0.22A
+12.0V
0.25A
0.22A
-12.0V
0.25A
TPAM05S-150036
0.36A
15.0V
0.43A
TPAM05D-150018
0.18A
+15.0V
0.20A
0.18A
-15.0V
0.20A
TPAM05S-180030
0.30A
18.0V
0.36A
TPAM05S-240022
0.22A
24.0V
0.26A
Symbols: "★" OVP built-in.
"@" Adjustable.
"║" Double Feedback.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 107.0g (3.77 Oz.)
PIN ASSIGNMENT
PIN NO.
PIN #1.
PIN #2.
PIN #3.
PIN #4.
PIN #5.
PIN #6.
SINGLE
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
NO PIN
DC-COM
DUAL
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
DC-COM
-VO2
DERATING CHART
CASE SIZE: AM01
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com