Total Power International, Inc. ON

Total Power International, Inc.
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 16 WATTS SINGLE & DUAL OUTPUT
TPAM16S & TPAM16D SERIES
FEATURES:
„ON-BOARD AC/DC MODULAR
POWER SUPPLIES
„UNIVERSAL AC INPUT RANGE
„COMPACT IN SIZE
„MEET UNIVERSAL SAFETY STANDARDS
„EMI MEET CISPR PUB.22/ FCC CLASS B
„CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac.
Input Frequency: 47-63 Hz. (50/60 Hz. Nom.).
Input Current: 0.33A @115Vac/0.16A @230Vac typical.
Inrush Current: 32.5A typical peak @ 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac. for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 20mS @115Vac, 120mS @230Vac typical.
Earth Leakage: Less than 3.5mA @230Vac typical.
Remote On/Off: TTL/CMOS-Compatible Output Control.
Positive Logic version for Standard set up:
ON(Enable)=Open(or 2.5-5.0Vdc above Com)
OFF(Disable)=Short(or 0-0.8Vdc above Com)
Negative Logic version option available by adding a
“N”suffix to the end of Model #.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 12-17 Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltage.
TPAM16S ±0.1% typical.
TPAM16D ±0.5% typical.
Load Regulation: Various with output voltage.
TPAM16S ±1.0% typical.
TPAM16D ±2.0-4.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 70-82% typical. (Various with output voltage).
Switching Frequency: 83K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Power Density: 3.10Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25°C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: 0.02% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load >+50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
Due to requests in market and advances in technology, specifications subject to change without notice.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
TPAM16S-033370
TPAM16S-050300
TPAM16S-090170
TPAM16S-120135
TPAM16S-150110
TPAM16S-240070
TPAM16S-480035
DUAL OUTPUT
VO1 Ϫ @
TYP.
3.70A
3.00A
1.70A
1.35A
1.10A
0.70A
0.35A
VOLT. PEAK
3.3V 4.44A
5.0V 3.60A
9.0V 2.04A
12.0V 1.62A
15.0V 1.32A
24.0V 0.84A
48.0V 0.42A
MODEL NO.
TPAM16D-033180
TPAM16D-050150
TPAM16D-120068
TPAM16D-150055
+VO1 Ϫ @
TYP. VOLT. MAX.
1.80A +3.3V
2.07A
1.50A +5.0V
1.72A
0.68A +12.0V
0.78A
0.55A +15.0V
0.63A
TYP
1.80A
1.50A
0.68A
0.55A
-VO2 Э
VOLT.
-3.3V
-5.0V
-12.0V
-15.0V
MAX.
2.07A
1.72A
0.78A
0.63A
Symbols: "Ϫ" OVP built-in.
"@" Adjustable.
"Э" Double Feedback.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 145.0g(5.11Oz)
PIN ASSIGNMENT
PIN NO.
PIN #1.
PIN #2.
PIN #3.
PIN #4.
PIN #5.
PIN #6.
PIN #7.
SINGLE
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
NO PIN
DC COM
Remote ON/OFF
DUAL
AC-GROUND
AC-NEUTRAL
AC-LINE
+VO1
DC-COM
-VO2
Remote ON/OFF
DERATING CHART
CASE SIZE: AM03
!
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
Total Power International, Inc.
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 16 WATTS TRIPLE OUTPUT TPAM16-T SERIES
FEATURES:
„ON-BOARD AC/DC MODULAR
POWER SUPPLIES
„UNIVERSAL INPUT RANGE
„COMPACT IN SIZE
„MEET UNIVERSAL SAFETY STANDARDS
„EMI MEET CISPR PUB.22 / FCC CLASS B
„CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac.
Input Frequency: 47-63 Hz. (50/60 Hz. Nom.).
Input Current: 0.33A @115Vac./0.16A @230Vac typical.
Inrush Current: 32.5A peak @230Vac typical.
Input Fuse: Use external fuse. 1.0A/250Vac for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 20mS @115Vac, 100mS @230Vac typical.
Earth Leakage: Less than 3.5mA @230Vac.
Remote On/Off: TTL/CMOS-Compatible Output Control.
Positive Logic version for Standard set up:
ON(Enable)=Open(or 2.5-5.0Vdc above Com)
OFF(Disable)=Short(or 0-0.8Vdc above Com)
Negative Logic version option available by adding a
“N”suffix to the end of Model #.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 15-16.5 Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltage ±0.5% typical.
Load Regulation: Various with output voltage.
VO1 ±5.0 typical, VO2 ±4.0% typical, VO3 ±2.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 70-76% typical. (Various with output voltage).
Switching Frequency: 83KHz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Power Density: 3.12 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25°C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.032% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load >+50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
Due to requests in market and advances in technology, specifications subject to change without notice.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
TRIPLE OUTPUT
MODEL NO.
TPAM16T-5/09
TPAM16T-5/12
TPAM16T-5/15
TPAM16T-5/24
TPAM16T-3/05
TPAM16T-3/12
TPAM16T-3/15
TPAM16T-3/5,12
TPAM16T-3/24
+VO1 @ Ϫ
TYP. VOLT. MAX
1.8A +5.0V 2.0A
1.8A +5.0V 2.0A
1.8A +5.0V 2.0A
1.8A +5.0V 2.0A
1.8A +3.3V 2.0A
1.8A +3.3V 2.0A
1.8A +3.3V 2.0A
1.8A +3.3V 2.0A
1.8A +3.3V 2.0A
-VO3 Э
+VO2 †
TYP.
VOLT. MAX.
0.40A
+9.0V 0.46A
0.30A +12.0V 0.34A
0.24A +15.0V 0.27A
0.16A +24.0V 0.18A
0.75A
+5.0V 0.86A
0.30A +12.0V 0.35A
0.25A +15.0V 0.28A
0.75A
+5.0V 0.86A
0.16A +24.0V 0.18A
TYP.
VOLT. MAX.
0.40A
-9.0V 0.46A
0.30A -12.0V 0.34A
0.24A -15.0V 0.27A
0.16A -24.0V 0.18A
0.75A
-5.0V 0.86A
0.30A -12.0V 0.35A
0.25A -15.0V 0.28A
0.30A -12.0V 0.34A
0.16A -24.0V 0.18A
Symbols: "Ϫ" OVP built-in.
"@" Adjustable.
"Э" Double Feedback.
"†" Stacked on main O/P.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 145.0g(5.11Oz)
PIN ASSIGNMENT
PIN NO.
PIN #1.
PIN #2.
PIN #3.
PIN #4.
PIN #5.
PIN #6.
PIN #7.
PIN #8.
TRIPLE OUTPUT
AC-GROUND
AC-NEUTRAL
AC-LINE
-VO3
+VO1
DC-COM
+VO2
Remote ON/ OFF
DERATING CHART
CASE SIZE: AM03
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com