hitron-e.com

H HiTRON
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 10 WATTS SINGLE & DUAL OUTPUT
HAM10S & HAM10D SERIES
FEATURES:






ON-BOARD AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typical 90-264Vac. (or 110-340Vdc).
Input Frequency: 47-63 Hz. (50/60Hz.Nom.) or DC.
Input Current: 0.3A at 115Vac./ 0.13A at 230Vac.
Inrush Current: 32.5A peak at 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22/ FCC Class B.
Hold-up time: 20mS at 115Vac, 80mS at 230Vac.
Earth Leakage Current: Less than 3.5mA at 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typical 10 Watts.
Output Indicator: LED.
Line Regulation: Various with output voltage.
HAM10S typical ±0.1%.
HAM10D typical ±0.2%.
Load Regulation: Various with output voltage.
HAM10S typical ±1.0%.
HAM10D typical ±2.0%.
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 67-79%. (Various with output voltage)
Switching Frequency: 75K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Weight: 120g (4.23 Oz).
Power Density: 2.51 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 100,000 hours. Mil Std 217, 25°C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load at +70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.02% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C at full load.
At least 100LFM moving air is recommended
for full load > +50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
(3) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
-113-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
DUAL OUTPUT
VO1 @ ★
TYP. VOLT. PEAK
MODEL NO.
+VO1 @ ★
-VO2 ‖
TYP.
VOLT.
MAX.
TYP.
VOLT. MAX.
HAM10S-033243 2.43A
3.3V 2.91A
HAM10D-033120
1.20A
+3.3V
1.38A
1.20A
-3.3V 1.38A
HAM10S-050200 2.00A
5.0V 2.44A
HAM10D-050100
1.00A
+5.0V
1.15A
1.00A
-5.0V 1.15A
HAM10S-090112 1.12A
9.0V 1.34A
HAM10D-120045
0.45A +12.0V
0.51A
0.45A -12.0V 0.51A
HAM10D-150035
0.35A +15.0V
0.40A
0.35A -15.0V 0.40A
HAM10S-120090 0.90A 12.0V 1.08A
HAM10S-150072 0.72A 15.0V 0.86A
HAM10S-240045 0.45A 24.0V 0.54A
Symbols: "★" OVP built-in. "@" Adjustable. "‖"Double Feedback.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
HAM10S-480025 0.25A 48.0V 0.30A
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 120.0g (4.23 Oz.)
PIN ASSIGNMENT
PIN NO.
PIN #1.
PIN #2.
PIN #3.
PIN #4.
PIN #5.
PIN #6.
SINGLE
AC-GROUND
AC-NEUTRAL
AC-LINE
+ VO1
NO PIN
DC-COM
DERATING CHART
CASE SIZE: AM02
-114-
DUAL
AC-GROUND
AC-NEUTRAL
AC-LINE
+ VO1
DC-COM
-VO2
H HiTRON
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 10 WATTS TRIPLE OUTPUT HAM10-T SERIES
FEATURES:






ON-BOARD AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac.
Input Frequency: 47-63 Hz. (50/60 Hz. Nom.)
Input Current: Typical 0.3A at 115Vac./0.13A at 230Vac.
Inrush Current: Typical 32.5A peak at 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC class B.
Hold-up time: Typical 20mS at 115Vac, 80mS at 230Vac.
Earth Leakage Current: Less than 3.5mA at 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typical 10 Watts.
Output Indicator: LED.
Line Regulation: Various with output voltage, typ. ±0.5%.
Load Regulation: Various with output voltage.
VO1 typ. ±5.0%, VO2 typ. ±3.0%, VO3 typ. ±4.0%.
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 70-75%. (Various with output voltage).
Switching Frequency: 83KHz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Power Density: 2.51 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25 °C.
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load at +70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ±0.03% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C at full load.
At least 100LFM moving air is recommended
for full load > +50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
(3) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
-115-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
TRIPLE OUTPUT
MODEL NO.
+VO1 @★
-VO3 ‖
+VO2 †
VOLT. MAX.
TYP.
VOLT.
MAX.
TYP.
VOLT. MAX.
TYP.
HAM10T-5/09
1.0A
+5.0V
1.15A
0.27A
+9.0V
0.31A
0.27A
-9.0V
0.31A
HAM10T-5/12
1.0A
+5.0V
1.15A
0.25A
+12.0V
0.28A
0.25A
-12.0V
0.28A
HAM10T-5/15
1.0A
+5.0V
1.15A
0.20A
+15.0V
0.23A
0.20A
-15.0V
0.23A
HAM10T-5/24
1.0A
+5.0V
1.15A
0.12A
+24.0V
0.14A
0.12A
-24.0V
0.14A
HAM10T-3/05
1.0A
+3.3V
1.15A
0.40A
+5.0V
0.46A
0.40A
-5.0V
0.46A
HAM10T-3/12
1.0A
+3.3V
1.15A
0.25A
+12.0V
0.29A
0.25A
-12.0V
0.29A
HAM10T-3/15
1.0A
+3.3V
1.15A
0.20A
+15.0V
0.23A
0.20A
-15.0V
0.23A
HAM10T-3/5,12
1.0A
+3.3V
1.15A
0.40A
+5.0V
0.46A
0.25A
-12.0V
0.28A
HAM10T-3/24
1.0A
+3.3V
1.15A
0.12A
+24.0V
0.14A
0.12A
-24.0V
0.14A
Symbols: "★" OVP built-in.
"@" Adjustable.
"‖" Double Feedback.
"†" Stacked on main O/P.
Note: (1) Max. (maximum load) is the continuous operating load of each rail,
but the max. load of each rail can not be drawn from all outputs at the same time.
(2) Peak output, less than 60 Sec. with duty cycle <10%.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 120.0g (4.23 Oz.)
PIN ASSIGNMENT
PIN NO.
PIN #1
PIN #2
PIN #3
PIN #4
PIN #5
PIN #6
PIN #7
TRIPLE
AC-GROUND
AC-NEUTRAL
AC-LINE
+ VO2
+ VO1
DC-COM
- VO3
DERATING CHART
CASE SIZE: AM02
-116-