H HiTRON ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 10 WATTS SINGLE & DUAL OUTPUT HAM10S & HAM10D SERIES FEATURES: ON-BOARD AC/DC MODULAR POWER SUPPLIES UNIVERSAL AC INPUT RANGE COMPACT IN SIZE MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.22 / FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typical 90-264Vac. (or 110-340Vdc). Input Frequency: 47-63 Hz. (50/60Hz.Nom.) or DC. Input Current: 0.3A at 115Vac./ 0.13A at 230Vac. Inrush Current: 32.5A peak at 230Vac. Input Fuse: Use external fuse. 1.0A/250Vac for primary fuse is suggested. Dielectric Withstand: Meet IEC950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB.22/ FCC Class B. Hold-up time: 20mS at 115Vac, 80mS at 230Vac. Earth Leakage Current: Less than 3.5mA at 230Vac. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typical 10 Watts. Output Indicator: LED. Line Regulation: Various with output voltage. HAM10S typical ±0.1%. HAM10D typical ±0.2%. Load Regulation: Various with output voltage. HAM10S typical ±1.0%. HAM10D typical ±2.0%. Noise & Ripple: Typical 1.0% peak to peak. OVP: Built-in on main output. Adjustability: From -10% of main output till OVP. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typical 67-79%. (Various with output voltage) Switching Frequency: 75K Hz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Typical peak deviation 250mV, Recovery time < 3mS for a 25% load change. Case: Impact resistant thermo-plastic enclosure. Weight: 120g (4.23 Oz). Power Density: 2.51 Watts. / Cubic inch. Safety Standard: EN60950/ UL1950 Class I. MTBF: 100,000 hours. Mil Std 217, 25°C. Operating Temperature: -10 to +70°C range. -10°C to +50°C full load without derating. From +50°C, derating linearly to half load at +70°C. (Refer to Derating Chart.) Storage Temperature: -20°C to +85°C. Temperature Coefficient: ± 0.02% /°C. Humidity: Up to 95%RH, Non-condensing. Cooling: Convection cooling for +50°C at full load. At least 100LFM moving air is recommended for full load > +50°C in a confined area. Commercial Grade only. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load. (3) Due to requests in market and advances in technology, specifications subject to change without notice. For the details of safety approval, please consult the factory. -113- OUTPUT VOLTAGE/ CURRENT RATINGS CHART SINGLE OUTPUT MODEL NO. DUAL OUTPUT VO1 @ ★ TYP. VOLT. PEAK MODEL NO. +VO1 @ ★ -VO2 ‖ TYP. VOLT. MAX. TYP. VOLT. MAX. HAM10S-033243 2.43A 3.3V 2.91A HAM10D-033120 1.20A +3.3V 1.38A 1.20A -3.3V 1.38A HAM10S-050200 2.00A 5.0V 2.44A HAM10D-050100 1.00A +5.0V 1.15A 1.00A -5.0V 1.15A HAM10S-090112 1.12A 9.0V 1.34A HAM10D-120045 0.45A +12.0V 0.51A 0.45A -12.0V 0.51A HAM10D-150035 0.35A +15.0V 0.40A 0.35A -15.0V 0.40A HAM10S-120090 0.90A 12.0V 1.08A HAM10S-150072 0.72A 15.0V 0.86A HAM10S-240045 0.45A 24.0V 0.54A Symbols: "★" OVP built-in. "@" Adjustable. "‖"Double Feedback. Note: (1) Max. (maximum load) is the continuous operating load of each rail, but the max. load of each rail can not be drawn from all outputs at the same time. (2) Peak output, less than 60 Sec. with duty cycle <10%. HAM10S-480025 0.25A 48.0V 0.30A MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 120.0g (4.23 Oz.) PIN ASSIGNMENT PIN NO. PIN #1. PIN #2. PIN #3. PIN #4. PIN #5. PIN #6. SINGLE AC-GROUND AC-NEUTRAL AC-LINE + VO1 NO PIN DC-COM DERATING CHART CASE SIZE: AM02 -114- DUAL AC-GROUND AC-NEUTRAL AC-LINE + VO1 DC-COM -VO2 H HiTRON ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 10 WATTS TRIPLE OUTPUT HAM10-T SERIES FEATURES: ON-BOARD AC/DC MODULAR POWER SUPPLIES UNIVERSAL INPUT RANGE COMPACT IN SIZE MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.22 / FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: 90-264Vac. Input Frequency: 47-63 Hz. (50/60 Hz. Nom.) Input Current: Typical 0.3A at 115Vac./0.13A at 230Vac. Inrush Current: Typical 32.5A peak at 230Vac. Input Fuse: Use external fuse. 1.0A/250Vac for the primary fuse is suggested. Dielectric Withstand: Meet IEC950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB.22 / FCC class B. Hold-up time: Typical 20mS at 115Vac, 80mS at 230Vac. Earth Leakage Current: Less than 3.5mA at 230Vac. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typical 10 Watts. Output Indicator: LED. Line Regulation: Various with output voltage, typ. ±0.5%. Load Regulation: Various with output voltage. VO1 typ. ±5.0%, VO2 typ. ±3.0%, VO3 typ. ±4.0%. Noise & Ripple: Typical 1.0% peak to peak. OVP: Built-in on main output. Adjustability: From -10% of main output till OVP. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typical 70-75%. (Various with output voltage). Switching Frequency: 83KHz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Typical peak deviation 250mV, Recovery time < 3mS for a 25% load change. Case: Impact resistant thermo-plastic enclosure. Power Density: 2.51 Watts. / Cubic inch. Safety Standard: EN60950/ UL1950 Class I. MTBF: 110,000 hours. Mil Std 217, 25 °C. Operating Temperature: -10 to +70°C range. -10°C to +50°C full load without derating. From +50°C, derating linearly to half load at +70°C. (Refer to Derating Chart.) Storage Temperature: -20°C to +85°C. Temperature Coefficient: ±0.03% /°C. Humidity: Up to 95%RH, Non-condensing. Cooling: Convection cooling for +50°C at full load. At least 100LFM moving air is recommended for full load > +50°C in a confined area. Commercial Grade only. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load. (3) Due to requests in market and advances in technology, specifications subject to change without notice. For the details of safety approval, please consult the factory. -115- OUTPUT VOLTAGE/ CURRENT RATINGS CHART TRIPLE OUTPUT MODEL NO. +VO1 @★ -VO3 ‖ +VO2 † VOLT. MAX. TYP. VOLT. MAX. TYP. VOLT. MAX. TYP. HAM10T-5/09 1.0A +5.0V 1.15A 0.27A +9.0V 0.31A 0.27A -9.0V 0.31A HAM10T-5/12 1.0A +5.0V 1.15A 0.25A +12.0V 0.28A 0.25A -12.0V 0.28A HAM10T-5/15 1.0A +5.0V 1.15A 0.20A +15.0V 0.23A 0.20A -15.0V 0.23A HAM10T-5/24 1.0A +5.0V 1.15A 0.12A +24.0V 0.14A 0.12A -24.0V 0.14A HAM10T-3/05 1.0A +3.3V 1.15A 0.40A +5.0V 0.46A 0.40A -5.0V 0.46A HAM10T-3/12 1.0A +3.3V 1.15A 0.25A +12.0V 0.29A 0.25A -12.0V 0.29A HAM10T-3/15 1.0A +3.3V 1.15A 0.20A +15.0V 0.23A 0.20A -15.0V 0.23A HAM10T-3/5,12 1.0A +3.3V 1.15A 0.40A +5.0V 0.46A 0.25A -12.0V 0.28A HAM10T-3/24 1.0A +3.3V 1.15A 0.12A +24.0V 0.14A 0.12A -24.0V 0.14A Symbols: "★" OVP built-in. "@" Adjustable. "‖" Double Feedback. "†" Stacked on main O/P. Note: (1) Max. (maximum load) is the continuous operating load of each rail, but the max. load of each rail can not be drawn from all outputs at the same time. (2) Peak output, less than 60 Sec. with duty cycle <10%. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 120.0g (4.23 Oz.) PIN ASSIGNMENT PIN NO. PIN #1 PIN #2 PIN #3 PIN #4 PIN #5 PIN #6 PIN #7 TRIPLE AC-GROUND AC-NEUTRAL AC-LINE + VO2 + VO1 DC-COM - VO3 DERATING CHART CASE SIZE: AM02 -116-