ETC PS-65-12

MEAN WELL
PS-65
SWITCHING POWER SUPPLY
SERIES
ISO-9001 CERTIFIED MANUFACTURER
.LOW COST, HIGH RELIABILITY
.COMPACT SIZE, LIGHT WEIGHT
.105ºC OUTPUT CAPACITOR
.100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
MODEL
PS-65-5
DC OUTPUT VOLTAGE
3.3V
5V
7.5V
OUTPUT V. TOLERANCE
±3%
±3%
±3%
±2%
±2%
±2%
±2%
±2%
±2%
OUTPUT RATED CURRENT
12A
12A
8A
5.2A
4.7A
4.2A
2.7A
2.4A
1.35A
OUTPUT MIN. CURRENT
0A
0A
0A
0A
0A
0A
0A
0A
0A
OUTPUT MAX. CURRENT
15.2A
13.8A
9.6A
6A
5.4A
4.8A
3A
2.7A
1.5A
RIPPLE & NOISE p-p
80mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
LINE REGULATION
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
LOAD REGULATION
±3%
±3%
±3%
±2%
±2%
±2%
±2%
±2%
±2%
39.6W
60W
60W
62.4W
63.5W
63W
64.8W
64.8W
64.8W
RATED OUTPUT POWER
MAXIMUM OUTPUT POWER
EFFICIENCY
PS-65-7.5 PS-65-12
PS-6513.5
PS-65-3.3
SPECIFICATION
12V
13.5V
PS-65-15 PS-65-24 PS-65-27 PS-65-48
15V
24V
27V
RATED OUTPUT POWER FOR CONVECTION; 72W (+3.3V:50W;+5V:69W) WITH 18 CFM MIN. FORCED
AIR
69%
76%
79%
79%
79%
79%
80%
80%
DC VOLTAGE ADJ.
+10,-5%
INPUT VOLTAGE RANGE
90~264VAC 47~440Hz ; 120~370VDC
AC CURRENT
1.5A/115V 0.9A/230V
INRUSH CURRENT
COLD START 20A/115V 40A/230V
LEAKAGE CURRENT
<0.5mA/240VAC
OVERLOAD PROTECTION
73~105W (3.3V:51~75W)(5V:70~105W) TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO
RECOVERY
OVER VOLTAGE PROTECTION
115%~135%
TEMP. COEFFICIENT
±0.04% / ºC (0~50ºC)
SETUP, RISE, HOLD UP TIME
800ms, 20ms, 20ms
VIBRATION
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
STORAGE TEMP., HUMIDITY
-20ºC~+85ºC, 10%~95% RH
DIMENSION
127*76.2*42mm (L*W*H) PCB ONLY
WEIGHT
0.28Kgs
SAFETY STANDARDS
UL1950, TUV EN60950 APPROVED
EMC STANDARDS
CISPR22 (EN55022), IEC1000-4-2,3,4,5 IEC1000-3-2,3 VERIFICATION
NOTE :
48V
80%
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT RELATED TO MAXIMUM OUTPUT POWER.
6.MOUNTING HOLES M1 AND M2 SHOULD BE GROUNDED FOR EMI PURPOSES.
2002-04-29