CUI VQP-100B

•
VQP-100B Switching Power Supply
Features
·Universal AC input / Full range
·Built-in active PFC function, PF>0.95
·Protections:Short circuit/Over load/Over voltage
·Free air cooling convection
·CH4: Polarity is selectable
·Fixed switching frequency at 100KHz(Optional)
·3 year warranty
CH1
CH2
CH3
CH4
DC output voltage
5V
12V
-12V
-5V
Output V. tolerance
±3%
±6%
±10,-6%
±5%
Output rated current
10A
3A
1A
0.6A
Output current range
2-10A
0.3-4A
0.15-1A
0-1A
Ripple & noise p-p
Line regulation
Load regulation
Max. output power
Efficiency
DC voltage adj.
Input voltage range
AC current
100mV
150mV
±1%
±2%
±2%
±6%
101W
76%
CH1: +10, -5%
90~264VAC 47~63Hz; 127-370VDC
1.5A/115V 0.75A/230V
150mV
±2%
±6%
100mV
±1%
±2%
Inrush current
Leakage current
Overload protection
Over voltage protection
Over temp. protection
Temperature coefficient
Set up, rise, hold up time
Power factor
Vibration
Withstand voltage
cold start 40A
<3.5mA/240VAC
105%~135%, pulsing (hiccup mode), auto restart.
CH1:5.75~6.75V
95°C±5°C TSW1 type: shutdown
reset: auto recovery
±0.3%/ °C(0~50°C)
1s, 50ms, 16ms
PF>0.95/230VAC, PF>0.98/115VAC
10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC for 1 min.
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60°C (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
7.83x3.9x1.97 inches (199x99x50mm) case: 916A
1.61lbs (1.1Kgs)
UL1950, TUV EN60950 approved
EN55022 class B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3,
EN55024 verification
Notes:
1.
2.
3.
4.
5.
6.
All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
Tolerance includes set up tolerance, line regulation, load regulation
Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
Line regulation is measured from low line to high line at rated load
Load regulation is measured from 20% to 100% rated load, and other outputs at 60% rated load.
Each output provides up to maximum current, but total load can not exceed max. output power.
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise
customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for
customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s
published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258
•
Derating Curve
VQP-100B Switching Power Supply
Output Derating VS Input Voltage
Dimensions
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258