• VQP-100B Switching Power Supply Features ·Universal AC input / Full range ·Built-in active PFC function, PF>0.95 ·Protections:Short circuit/Over load/Over voltage ·Free air cooling convection ·CH4: Polarity is selectable ·Fixed switching frequency at 100KHz(Optional) ·3 year warranty CH1 CH2 CH3 CH4 DC output voltage 5V 12V -12V -5V Output V. tolerance ±3% ±6% ±10,-6% ±5% Output rated current 10A 3A 1A 0.6A Output current range 2-10A 0.3-4A 0.15-1A 0-1A Ripple & noise p-p Line regulation Load regulation Max. output power Efficiency DC voltage adj. Input voltage range AC current 100mV 150mV ±1% ±2% ±2% ±6% 101W 76% CH1: +10, -5% 90~264VAC 47~63Hz; 127-370VDC 1.5A/115V 0.75A/230V 150mV ±2% ±6% 100mV ±1% ±2% Inrush current Leakage current Overload protection Over voltage protection Over temp. protection Temperature coefficient Set up, rise, hold up time Power factor Vibration Withstand voltage cold start 40A <3.5mA/240VAC 105%~135%, pulsing (hiccup mode), auto restart. CH1:5.75~6.75V 95°C±5°C TSW1 type: shutdown reset: auto recovery ±0.3%/ °C(0~50°C) 1s, 50ms, 16ms PF>0.95/230VAC, PF>0.98/115VAC 10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC for 1 min. Isolation resistance Working temp., humidity Storage temp., humidity Dimensions Weight Safety standards EMC standards I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min. -10°C~+60°C (refer to output derating curve), 20%-90% RH -20°C~+85°C, 10%-95% RH 7.83x3.9x1.97 inches (199x99x50mm) case: 916A 1.61lbs (1.1Kgs) UL1950, TUV EN60950 approved EN55022 class B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3, EN55024 verification Notes: 1. 2. 3. 4. 5. 6. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient Tolerance includes set up tolerance, line regulation, load regulation Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor Line regulation is measured from low line to high line at rated load Load regulation is measured from 20% to 100% rated load, and other outputs at 60% rated load. Each output provides up to maximum current, but total load can not exceed max. output power. V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 • Derating Curve VQP-100B Switching Power Supply Output Derating VS Input Voltage Dimensions V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258