MEAN WELL QP-375 SERIES SWITCHING POWER SUPPLY ISO-9001 CERTIFIED MANUFACTURER .LOW COST, HIGH RELIABILITY .ISOLATE CH3 & CH4 DC OUTPUT .105ºC OUTPUT CAPACITOR .MAIN OUTPUT REMOTE SENSE .INTERNATIONAL AC INPUT RANGE .POWER GOOD AND FAIL SIGNAL .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED QP-375-5A MODEL QP-375-5B QP-375-5C SPECIFICATION CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC OUTPUT VOLTAGE +5V +12V 12V 12V +5V +12V 12V 5V +5V +12V 15V 15V OUTPUT V. TOLERANCE ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% OUTPUT RATED CURRENT 30A 10A 6A 3A 30A 10A 6A 3A 30A 9A 4A 4A OUTPUT CURRENT RANGE 3.5-40A 0-10A 0-6A 0-3A 3.5-40A 0-10A 0-6A 0-3A 3.5-40A 0-9A 0-4A 0-4A 40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 4A 4A RIPPLE & NOISE (p-p) 100mV 150mV 150mV 50mV 100mV 120mV 120mV 50mV 100mV 150mV 150mV 240mV LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% PEAK CURRENT DC OUTPUT POWER 378W (max.) EFFICIENCY DC VOLTAGE ADJ. 357W (max.) 378W (max.) 77% 77% 77% CH1,2,3,4:+10,-5% CH1,2,3:+10,-5% CH1,2,3,4:+10,-5% INPUT VOLTAGE RANGE 85~264VAC 47~63Hz; 120~370VDC AC CURRENT 6A/115V 3A/230V POWER FACTOR PF>0.95/230VAC, PF>0.98/115VAC OUTPUT GOOD/INPUT POWER FAIL 10ms/1ms INRUSH CURRENT COLD START 45A LEAKAGE CURRENT <2mA/240VAC OVERLOAD PROTECTION 105%~135% TYPE: PULSE BY PULSE RESET: AUTO RECOVERY OVER VOLTAGE PROTECTION CH1:5.75~6.75V TYPE:SHUTDOWN OVER TEMP. PROTECTION 80ºC~±5ºC (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY REMOTE CONTROL RC+/RC-:0~0.8V POWER ON ; 4V~10V POWER OFF TEMP. COEFFICIENT ±0.03% / ºC (0~50ºC) SETUP, RISE, HOLD UP TIME 800ms, 50ms, 20ms VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH DIMENSION 278*127*63.5mm WEIGHT 2.3Kgs SAFETY STANDARDS UL1950, TUV EN60950 APPROVED EMC STANDARDS CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS. NEXT ( MECHANICAL INFO ) 2002-09-23 MEAN WELL QP-375 SERIES SWITCHING POWER SUPPLY ISO-9001 CERTIFIED MANUFACTURER .LOW COST, HIGH RELIABILITY .ISOLATE CH3 & CH4 DC OUTPUT .105ºC OUTPUT CAPACITOR .MAIN OUTPUT REMOTE SENSE .INTERNATIONAL AC INPUT RANGE .POWER GOOD AND FAIL SIGNAL .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED QP-375-5D MODEL QP-375-5E SPECIFICATION CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC OUTPUT VOLTAGE +5V +12V 12V 24V +5V +12V 24V 24V OUTPUT V. TOLERANCE ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% OUTPUT RATED CURRENT 30A 9A 4A 3A 30A 9A 3A 2A OUTPUT CURRENT RANGE 3.5-40A 0-9A 0-4A 0-3A 3.5-40A 0-9A 0-3A 0-2A PEAK CURRENT 40A 16A 6A 3A 40A 16A 4A 3A RIPPLE & NOISE 100mVp-p 120mVp-p 120mVp-p 240mVp-p 100mVp-p 120mVp-p 120mVp-p 240mVp-p LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% DC OUTPUT POWER 378W (max.) EFFICIENCY DC VOLTAGE ADJ. 378W (max.) 78% 78% CH1,2,3,4:+10,-5% CH1,2,3,4:+10,-5% INPUT VOLTAGE RANGE 85~264VAC 47~63Hz; 120~370VDC AC CURRENT 6A/115V 3A/230V POWER FACTOR PF>0.95/230VAC, PF>0.98/115VAC OUTPUT GOOD/INPUT POWER FAIL 10ms/1ms INRUSH CURRENT COLD START 45A LEAKAGE CURRENT <2mA/240VAC OVERLOAD PROTECTION 105%~135% TYPE: PULSE BY PULSE RESET: AUTO RECOVERY OVER VOLTAGE PROTECTION CH1:5.75~6.75V TYPE:SHUTDOWN OVER TEMP. PROTECTION 80ºC~±5ºC (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY REMOTE CONTROL RC+/RC-:0~0.8V POWER ON ; 4V~10V POWER OFF TEMP. COEFFICIENT ±0.03% / ºC (0~50ºC) SETUP, RISE, HOLD UP TIME 800ms, 50ms, 20ms VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH DIMENSION 278*127*63.5mm WEIGHT 2.3Kgs SAFETY STANDARDS UL1950, TUV EN60950 APPROVED EMC STANDARDS CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS. NEXT ( MECHANICAL INFO ) 2002-09-23 MEAN WELL QP-375 SERIES SWITCHING POWER SUPPLY ISO- 9001 CERTIFIED MANUFACTURER .LOW COST, HIGH RELIABILITY .ISOLATE CH3 & CH4 DC OUTPUT .105º C OUTPUT CAPACITOR .MAIN OUTPUT REMOTE SENSE .INTERNATIONAL AC INPUT RANGE .POWER GOOD AND FAIL SIGNAL .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED QP-375-24B MODEL SPECIFICATION CH1 DC OUTPUT VOLTAGE +24V +5V OUTPUT V. TOLERANCE ±1% ±1% CH2 CH3 QP-375-24C CH4 CH1 CH2 CH3 CH4 12V 12V +24V +5V 15V 15V ±1% ±1% ±1% ±1% ±1% ±1% OUTPUT RATED CURRENT 10A 10A 4A 4A 10A 10A 4A 4A OUTPUT CURRENT RANGE 1-10A 0-10A 0-4A 0-4A 1-10A 0-10A 0-4A 0-4A PEAK CURRENT 10A 16A 4A 4A 10A 16A 4A 4A RIPPLE & NOISE (p-p) 240mV 50mV 120mV 120mV 240mV 50mV 150mV 150mV LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% ±0.8% MAX. DC OUTPUT POWER 386W EFFICIENCY DC VOLTAGE ADJ. 410W 78% 80% CH1,2,3,4:±10% CH1,2,3,4:±10% INPUT VOLTAGE RANGE 85~264VAC 47~63Hz; 120~370VDC AC CURRENT 6A/115V 3A/230V INRUSH CURRENT COLD START 45A LEAKAGE CURRENT <2mA/240VAC OVERLOAD PROTECTION 105%~135% TYPE:PULSE BY PULSE OVER VOLTAGE PROTECTION CH1:27.6~32.4V TYPE:SHUTDOWN OVER TEMP. PROTECTION 80º C~±5º C (TSW1)TYPE:SHUTDOWN RESET:AUTO RECOVERY TEMP. COEFFICIENT ±0.03% / º C (0~50º C) SETUP, RISE, HOLD UP TIME 800ms, 50ms, 20ms POWER FACTOR PF>0.95/230VAC, PF>0.98/115VAC REMOTE CONTROL RC+/RC-:0~0.8V POWER ON ; 4V~10V POWER OFF OUTPUT GOOD/INPUT POWER FAIL 10ms/1ms VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10º C~+60º C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20º C~+85º C, 10%~95% RH DIMENSION 278*127*63.5mm WEIGHT 2.3Kgs SAFETY STANDARDS UL1950, TUV EN60950 APPROVED EMC STANDARDS CISPR22(EN55022) CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-3-2,3 VERIFICATION NOTE : RESET:AUTO RECOVERY 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25º C 70% RH. AMBIENT. 2.TOLERANCE : INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.PEAK CURRENT CAN NOT EXCEED 60 SEC. 7.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TATAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 8.ISOLATED CH3 & CH4 MAYBE SERIES CONNECTED OR CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS. 2002-09-05