JDSU FFS

COMMUNICATIONS COMPONENTS
Fused Coupler, Visible Light
Key Features
• Visible wavelength operation
• All fiber — no lens alignment
• No unwanted reflections
• Low light loss
• High power handling
Applications
• Visible and display systems
• Sensors
• Biomedical equipment
• Research
NORTH AMERICA : 800 498-JDSU (5378)
The JDSU visible light fused fiber coupler is a compact, low loss, fused component
(1x2, 2x2) that is bidirectional and splits or combines visible optical signals. It is
designed for use in display systems, test equipment, fiberoptic research, and fiber
sensors. The coupler uses advanced fused fiber technology to provide optimum
performance at wavelengths within the visible light spectrum. No light leaves the
fiber and therefore no alignment is required; and there are no unwanted
reflections. Furthermore the output fiber pigtails may be directly integrated into
beam delivery systems.
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
FUSED COUPLER, VISIBLE LIGHT
2
Configuration
(Note: 1x2 couplers for blue wavelengths (i.e. <500 nm) are supplied as 2x2 with an
external termination on port P4. )
1x2
P2 (Blue) SIGNAL (Input)
P1 (Red) COMMON (Input)
P3 (Red) TAP (Output)
2x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P4 (Blue)
P3 (Red) TAP (Output)
Insertion Loss
Coupling Ratio1
Grade2
Available Housing Option
Available Wavelength(s) Coupling Ratio Tolerance Excess Loss3
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
A
B
A
B
A
B
A
B
A
B
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
90/10
90/10
80/20
80/20
70/30
70/30
60/40
60/40
50/50
50/50
±2%
±3%
±3%
±4%
±3%
±4%
±4%
±5%
±5%
±6%
0.3 dB
0.5 dB
0.3 dB
0.5 dB
0.3 dB
0.5 dB
0.3 dB
0.5 dB
0.3 dB
0.5 dB
1. Other coupling ratio are available. Please contact JDSU for specifications of coupling ratios not listed.
2. In 2x2 couplers performance is not specified for launch through second input port P4 (colored blue)
3. Includes fiber losses for up to 1 m pigtail length. Does not include connector losses.
Housing Option
Housing Code
Description
1x2, 2x2 Dimensions (mm)
Pigtail
3
4
5
5
Regular
Ø 0.9 mm slim
Ø 0.9 mm semi-ruggedized
Ø 3.0 mm fully-ruggedised
3.0 (Ø) x 55 (L)
3.0 (Ø) x 76 (L)
5.0 (Ø) x 85 (L)
80 (L) x 10 (W) x 8 (H)
Primary coated fiber
0.9 mm loose tube
Ø 0.9 mm loose-tube
3.0 mm fan-out sleeving
FUSED COUPLER, VISIBLE LIGHT
3
Specifications
Parameter
Specification
Operating wavelength range
Operating temperature range1
Storage temperature range
Fiber type
Specified wavelength within the range of 450 to 700 nm
-40 to 75 °C
-40 to 85 °C
Short wavelength speciality fiber
1. For connectorised component, operating temperature range is -5 to 75 °C.
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
[email protected].
Sample: FFS-G32K31A10 (Fused Fiber Speciality Coupler, 532 nm, 50/50 coupling ratio, regular housing, 1x2, A grade, 1 m
pigtails, no connectors)
FFSCode
R
G
B
Code
Wavelength
(First Digit)
6xx nm (red)
5xx nm (green)
4xx nm (blue)
Wavelength
(Second and
Third Digit)
Examples:
33
x33 nm
32
x32 nm
57
x57 nm
Code
A
C
E
H
K
Coupling Ratio1
10%
20%
30%
40%
50%
Code
3
4
5
Housing2
Regular
Ø 0.9 mm slim
Ø 0.9 mm
semi-ruggedised
Ø 3.0mm fully
ruggedised
6
1. Other coupling ratio are available. Please contact JDSU
for ordering codes of coupling ratios not listed.
2. Connectors may be fitted to housing types 4, 5 and 6. For
connectorisation of housing type 3, please contact JDSU
sales office.
3. 1x2 couplers for blue wavelengths (i.e. <500 nm) are
supplied as a 2x2 with an external termination on port P4.
4. Minimum pigtail length. Other pigtail lengths are available
on request. When the pigtail has been modified to include
a connector, pigtail length measurment includes the
connector end face.
5. Excess loss in specification table does not include
connector losses.
6. LC connector is not available for housing code 6, fully
ruggedised housing.
NORTH AMERICA : 800 498-JDSU (5378)
Code
1
2
Configuration3
1x2
2x2
Code
A
B
Grade
Grade A
Grade B
Code
0
1
Pigtail Length4
0.5 meter
1 meter
Code
0
1
3
5
9
A
B
Connectors2, 5
None
FC/PC
FC/APC
SC/APC
FC/UPC
SC/UPC
LC6
LC is a registered trademark of Lucent Technologies.
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
Product specifications and descriptions in this document subject to change without notice. © 2007 JDS Uniphase Corporation 21027806 Rev. 003 10/05 FFSVL.DS.CC.AE
March 2007