JFW 50PA-365

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-365
HANDOVER TEST SYSTEM
Frequency Range
800-3000 MHz
Configuration
24 x 4 Handover Test System
See block diagram 092-5537
Impedance
50 Ohms nominal
VSWR
1.5:1 typical
1.7:1 maximum
Insertion Loss
35 dB typical @ 3000 MHz
Attenuation Range
0-127 dB in 1 dB steps
Attenuation Accuracy
(guaranteed monotonic)
± 0.5 dB or 2% (typical)
± 0.75 dB or 2% (maximum)
Power Divider Isolation
20 dB minimum
RF Input Power
+25 dBm operating
+30 dBm (no damage)
Switching Speed
10 microseconds typical
(after command is received and processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
Manual Control
Keypad and LCD display
Remote Control
Ethernet (10/100) and RS-232
Remote Commands
Set Attenuator
Read Attenuator
Fade Attenuator
Handover
Variable Handover
Change Baud Rate
Identification
Baud Rates (RS-232 mode)
9600, 19200, or 38400 Baud
RF Connector
SMA female
Temperature Range
0ºC to +50ºC
Physical Size
See outline drawing 092-5538
ECR/ECN #
Page 1 of 1
DATE
08/17/2007
REV
APPR / DATE
TRS 08/17/2007
14948
11/08/2007
A
TRS 11/08/2007
15109
01/03/2008
B
TRS 01/03/2008
ECR/ECN # DATE
15916
05/28/2008
16179
JFW FORM E-7-F REV F
08/07/2008
(SAx y <CR>)
(RAx <CR>)
(FAx y z t <CR>)
(HNDx y t)
(VHND Av Aw Vx Vy Tz)
(CBx <CR>)
(IDN <CR>)
REV
C
APPR / DATE
TRS 05/28/2008
D
TRS 08/07/2008