JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-366 HANDOVER TEST SYSTEM Frequency Range 700-3000 MHz Configuration 12 x 6 Handover Test System See block diagram 092-5539 Impedance 50 Ohms nominal VSWR 1.5:1 typical 1.7:1 maximum Insertion Loss 35 dB typical @ 700 MHz 39 dB typical @ 3000 MHz Attenuation Range 0-127 dB in 1 dB steps Attenuation Accuracy (guaranteed monotonic) ± 0.5 dB or 2% (typical) ± 0.75 dB or 2% (maximum) Power Divider Isolation 20 dB minimum RF Input Power 1 Watt average Switching Speed 10 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) AC Supply 100-240 VAC @ 47-63 Hz Manual Control Keypad and LCD display Remote Control Ethernet (10/100) and RS-232 Remote Commands Set Attenuator Read Attenuator Fade Attenuator Handover Variable Handover Change Baud Rate Identification Baud Rates (RS-232 mode) 9600, 19200, or 38400 Baud RF Connector SMA female Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-5540 --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F (SAx y <CR>) (RAx <CR>) (FAx y z t <CR>) (HNDx y t) (VHND Av Aw Vx Vy Tz) (CBx <CR>) (IDN <CR>) JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-366 HANDOVER TEST SYSTEM ECR/ECN # Page 2 of 2 DATE 14948 08/17/2007 11/08/2007 15037 12/06/2007 REV APPR / DATE ECR/ECN # DATE REV APPR / DATE A TRS 08/17/2007 TRS 11/08/2007 15109 15916 01/03/2008 05/28/2008 C D TRS 01/03/2008 TRS 05/28/2008 B TRS 12/06/2007 16179 08/07/2008 E TRS 08/07/2008 JFW FORM E-7-F REV F