JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-560 HANDOVER TEST SYSTEM Frequency Range 700-3000 MHz Configuration 4 x 8 Handover System (unit is bi-directional) See Block Diagram 092-6344 Impedance 50 Ohms nominal VSWR 1.7:1 maximum Insertion Loss 20 dB nominal @ 700 MHz 23 dB nominal @ 3000 MHz Attenuation Range 0-127 dB in 1 dB steps Attenuation Accuracy ± 0.5 dB or 2% (nominal) ± 0.75 dB or 2% (maximum) (whichever is greater) (guaranteed monotonic) Isolation 40 dB minimum (Input to Input) 30 dB minimum (Output to Output) RF Input Power +20 dBm average Switching Speed 5 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) AC Supply 100-240 VAC @ 47-63 Hz Remote Control RS-232 (9600, 19200, or 38400 Baud) Ethernet (TCP, 10/100, up to 4 users) Manual Control 20-button keypad and backlit LCD display --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-560 HANDOVER TEST SYSTEM Remote Commands Attenuator Control Commands: Set Attenuator, Set Attenuator with Response, Read Attenuator, Set All Attenuators, Read All Attenuators, Set Multiple Attenuator, Fade Attenuator, Variable Handover, Store, Recall System Commands: Identification, Pause -RS-232 Only: Change Baud -Ethernet Only: Disconnect, Close, Message, Clear RF Connector N female Temperature Range Operating: 0ºC to +70ºC Storage: -55ºC to +85ºC Physical Size See outline drawing 092-6343 ECR/ECN # 18137 Page 2 of 2 DATE 12/10/2009 REV APPR / DATE CLK 12/10/2009 01/22/2010 A CLK 01/22/2010 ECR/ECN # JFW FORM E-7-F REV F DATE REV APPR / DATE