JFW 50PA-560

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-560
HANDOVER TEST SYSTEM
Frequency Range
700-3000 MHz
Configuration
4 x 8 Handover System
(unit is bi-directional)
See Block Diagram 092-6344
Impedance
50 Ohms nominal
VSWR
1.7:1 maximum
Insertion Loss
20 dB nominal @ 700 MHz
23 dB nominal @ 3000 MHz
Attenuation Range
0-127 dB in 1 dB steps
Attenuation Accuracy
± 0.5 dB or 2% (nominal)
± 0.75 dB or 2% (maximum)
(whichever is greater)
(guaranteed monotonic)
Isolation
40 dB minimum (Input to Input)
30 dB minimum (Output to Output)
RF Input Power
+20 dBm average
Switching Speed
5 microseconds typical
(after command is received and
processed)
(3 milliseconds typical processing time)
AC Supply
100-240 VAC @ 47-63 Hz
Remote Control
RS-232 (9600, 19200, or 38400 Baud)
Ethernet (TCP, 10/100, up to 4 users)
Manual Control
20-button keypad and backlit LCD display
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 50PA-560
HANDOVER TEST SYSTEM
Remote Commands
Attenuator Control Commands:
Set Attenuator, Set Attenuator with
Response, Read Attenuator, Set All
Attenuators, Read All Attenuators, Set
Multiple Attenuator, Fade Attenuator,
Variable Handover, Store, Recall
System Commands:
Identification, Pause
-RS-232 Only: Change Baud
-Ethernet Only: Disconnect, Close,
Message, Clear
RF Connector
N female
Temperature Range
Operating: 0ºC to +70ºC
Storage:
-55ºC to +85ºC
Physical Size
See outline drawing 092-6343
ECR/ECN #
18137
Page 2 of 2
DATE
12/10/2009
REV
APPR / DATE
CLK 12/10/2009
01/22/2010
A
CLK 01/22/2010
ECR/ECN #
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE