JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-389 HANDOVER TEST SYSTEM Frequency Range 800-3000 MHz Configuration 12 x 4 Handover Test System See block diagram 092-5634 Impedance 50 Ohms nominal VSWR 1.5:1 typical 1.7:1 maximum Insertion Loss 29.2 dB typical @ 800 MHz 33.7 dB typical @ 3000 MHz Attenuation Range 0-127 dB in 1 dB steps Attenuation Accuracy (guaranteed monotonic) ± 0.5 dB or 2% (typical) ± 0.75 dB or 2% (maximum) Power Divider Isolation 20 dB minimum RF Input Power +25 dBm operating +30 dBm (no damage) Switching Speed 10 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) AC Supply 100-240 VAC @ 47-63 Hz Manual Control Keypad and LCD display Remote Control Ethernet (10/100) and RS-232 Remote Commands Set Attenuator Read Attenuator Fade Attenuator Handover Variable Handover Change Baud Rate Baud Rates (RS-232 mode) 9600, 19200, or 38400 Baud RF Connector SMA female Temperature Range 0ºC to +50ºC Physical Size See outline drawing 092-5635 --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F (SAx y <CR>) (RAx <CR>) (FAx y z t <CR>) (HNDx y t) (VHND Av Aw Vx Vy Tz) (CBx <CR>) JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-389 HANDOVER TEST SYSTEM ECR/ECN # Page 2 of 2 DATE REV APPR / DATE 15109 11/19/2007 01/03/2008 A TRS 11/19/2007 TRS 01/03/2008 15431 02/25/2008 B TRS 02/25/2008 ECR/ECN # 15916 16179 JFW FORM E-7-F REV F DATE 05/28/2008 08/07/2008 REV C D APPR / DATE TRS 05/28/2008 TRS 08/07/2008