LINKCOM LAL2097-50

LAL2097-50
Broadband Access Transformer
z
z
z
z
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 16-9= 1.4mH ±10% @ 10KHz/0.1V/Ser. (PIN 11-14 Short)
PIN 16-9= 28uH Max. @ 100KHz/100mV (PIN 11-14,1-4,2-3PIN Short)
Leakage
Inductance:
PIN 16-9= 20uH Max. @ 100KHz/100mV (PIN 11-14,6-7,5-8PIN Short)
PIN 16-1= 20pF Max. @ 100KHz/100mV (PIN 11-14,PIN 2-3 Short)
Interwinding
Capacitance
PIN 16-5= 20pF Max. @ 100KHz/100mV (PIN 11-14,PIN 6-7 Short)
PIN 16-9 to PIN 1-4= -90dB Max. @ 30KHz/3V ( PIN 11-14,PIN 2-3 Short)
T.H.D
PIN 16-9 to PIN 5-8= -90dB Max. @ 30KHz/3V ( PIN 11-14,PIN 6-7 Short)
PIN16 -9 = 2.1 ohm Max. ( PIN 11-14 Short)
PIN 1-4=1.95 ohm Max. (PIN2-3 Short) PIN 5-8 = 565mohm Max. (PIN6-7 Short)
D.C.R
Hi-POT :
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 1±2% :1 ( PIN 11-14,PIN 2-3 Short)
Turn Ratio:
PIN16-9 : PIN 5-8 = 4.25±2% :1 ( PIN 11-14,PIN 6-7 Short)
Schematic
Dimensions (Units: mm)
LALXXXX
LinkCom
X DATE CODE G
DOT PIN1
S
Mark
1.LAL****----LAL2097
2. X----PRODUCT LINE
3. DATE CODE----YYWW
There shall be no breakdown between winding 1,3,2,4,5,7,6,8 & 16,11,14 ,9 when
tested according to ITU-TK.21:2003 Enhanced level 6kV, par. 2.1.1.b using the test
procedures of K.44:2003.
Rev.B
4. G----RoHS