LAL2065-51 Broadband Access Transformer Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C Electrical Specifications @25℃ OCL: PIN 16-9= 1.4mH ±10% PIN 16-9= 18~28uH Leakage Inductance: @ 10KHz/0.1V/Ser. @ 100Hz/100mV PIN 16-9= 20uH Max. @ 100Hz/100mV IInterwinding Capacitance PIN 16-1= 60 pF Max. @ 100KHz/100mV PIN 16-5= 80 pF Max. @ 100KHz/100mV PIN 16-9 to PIN 1-4= -90dB Max. @ 30KHz/2V T.H.D PIN 16-9 to PIN 5-8= -90dB Max. @ 30KHz/2V PIN 1-4 = 7.1 ohm Max. D.C.R: PIN 5-8 = 1.08 ohm Max. PIN 16-9 = 7.5 ohm Max. Hi-POT : PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA PIN16-9 : PIN 1-4 = 1±2% :1 Turn Ratio: PIN16-9 : PIN 5-8 = 4.25±2% :1 Dimensions (Units: mm) 5.10 5.1±0.3 3.4±0.3 Schematic 3.40 3.40 SEC 1.70 0.7TYP. PRI LinkCom X DATE CODE G 0.5TYP. 13.5±0.5 G F 19.0 14.4±0.5 LAL**** 14.0 1 Rx 4 5 1.7±0.3 PIN1 1.70 1.00 Tx 8 C 13.5±0.5 14 9 Mark 1.LAL****----LAL2065 +1.00 -0.50 12.5 +0.15 -0.10 0.3 From Ver. A 11 7 6 SUGGESTED PAD LAYOUT A 12.6±0.5 16 3 2 B 2. X----PRODUCT LINE D 3. DATE CODE----YYWW 13.0±0.5 4. G----RoHS 15.5±0.5 E 17.0 +1.0 -0.5 1/1 LINE