LINKCOM LAL0389-50

LAL0389-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 8-5= 100uH ±10% @ 10KHz/0.1V/Ser.
Leakage
Inductance
PIN 8-5= 0.8uH Max. @ 100KHz/0.1V
Interwinding
Capacitance
PIN 1-8= 50 pF Max. @ 100KHz/0.1V
T.H.D
PIN 8-5 to PIN 1-4= -65dB Max. @ 30KHz/3.162V
D.C.R
PIN 1-4 = 0.510 ohm Max.
PIN 8-5 = 0.82 ohm Max.
Hi-POT
PRI. – SEC. =1500VAC/60Hz/2Seconds/1mA
Turn Ratio
PIN8-5 : PIN 1-4 = 1.86±2% :1
Dimensions (Units: mm)
Schematic
X DATE CODE G
8.0Max
A
4.1
8.8
LAL****
LinkCom
8.5Max
1.90
B
PIN1
0.80
10.0Max
SUGGESTED PAD LAYOUT
Mark
C
1.LAL****----LAL0389
2. X----PRODUCT LINE
1.9±0.5 E
SQ0.4±0.2 F
Form Ver. A
5.1Ref
7.8±0.5
D
3. DATE CODE----YYWW
4. G----RoHS