MEANWELL A-302-300

300W Modified Sine Wave DC-AC Power Inverter
A-301/302-300 series
Features :
12V or 24V DC input
Power ON-OFF switch
Input voltage range: -15% ~ +25%
Output voltage regulation: 10%
Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/
Over temp./Output short/Input polarity reverse/Over load.
Output waveform: Modified sine wave
Cooling fan ON-OFF control
Topology: Microprocessor
Approvals: e13/ CE
1 year warranty
E S
SPECIFICATION
Germany
ORDER NO.
OUTPUT
A301-300-B2
SAFETY MODEL NO.
A-300-300W
AC VOLTAGE
110V
RATED POWER
300W
SURGE POWER
600W
WAVEFORM
Modified Sine Wave
FREQUENCY
60Hz 1%
AC REGULATION
INPUT
ENVIRONMENT
A302-300-B2
A302-300-F3
230V
110V
230V
50Hz 1%
60Hz 1%
50Hz 1%
10%
TYPE-3* 1ea
TYPE-2* 2ea
DC CURRENT
35A
15A
NO LOAD CURRENT DRAW
0.36A
0.2A
DC VOLTAGE
12V
24V
VOLTAGE RANGE
10 ~ 15VDC
21 ~ 30VDC
EFFICIENCY (Typ.)
85%
Cigarette plug*1ea, Battery clip*1ea
FUSE
82%
Cigarette plug*1ea, Battery clip*1ea
Battery cord 35 A * 1, Cigarette plug 15 A* 1
BAT. LOW ALARM
10 0.5V
LVD
tested
20 0.8V
9.5 0.5V
19.5 0.8V
Battery cord 20 A * 1, Cigarette plug 10 A* 1
30 ~ 32V
15 ~ 17V
o
/ 113 9 F
OUTPUT SHORT
Shut-off
BAT. POLARITY
By fuse open
WORKING TEMP.
0 ~ 30
WORKING HUMIDITY
20% ~ 90% RH non-condensing
@ 100% load, 40
@ 50% load
EMC
o
STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH
TEMP. COEFFICIENT
0.05% / (0 ~ 50 )
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE
Compliance to EN61000-4-2,3
EMS IMMUNITY
OTHERS
LVD
MTBF
DIMENSION
PACKING
200Khrs min. MIL-HDBK-217F (25
165*88*74mm (L*W*H)
1.1kg ; 16pcs / 19kg / CARTON
COOLING
APPLICATIONS
>100W or >40 (NTC) fan on
Home appliance, Power tools, Office and Portable equipment and Vehicle ...etc.
SAFETY &
Germany
TYPE-3* 1ea
TYPE-2* 2ea
Green LED for power on; Red LED for power failure status
45 5
E S
10%
STANDARD RECEPTACLES
BAT. LOW SHUTDOWN
OVER VOLTAGE
PROTECTION
OVER TEMPERATURE
tested
A301-300-F3
LED INDICATOR
DC CONNECTOR
EMC
Compliance to EN60950
)
AC Output Receptacles (optional)
TYPE-1
TYPE-2
TYPE-3
TYPE-4
TYPE-5
TYPE-6
JAPAN
USA
EUROPE
UNIVERSAL
AUSTRALIA
U.K
File Name: A-301/302-300-SPEC 2007-05-14
300W Modified Sine Wave DC-AC Power Inverter
A-301/302-300 series
Mechanical Specification
Unit:mm
88
MADE IN TAIWAN
WARING:
DO NOT REVERSE INPUT
MADE IN TAIWAN
OFF
74
WARING:
DO NOT REVERSE INPUT
165
AIR FLOW
18.5
ON
ON
AC OUTPUT
OFF
BAT.LOW
OVER TEMP.
OVER LOAD
POWER
USA
BAT.LOW
OVER TEMP.
OVER LOAD
POWER
EUROPE
File Name: A-301/302-300-SPEC 2007-05-14